USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
4
Flush Mount Installation using optional Mud Box
Refer to instructions that are included with the AQL-SS-6B-BOX or AQL-SS-D-BOX Mud Box.
Cutout templates are provided on page 10.
Wiring
The AQL-SS-6B/D comes with 150 ft. of 5-conductor 24 AWG outdoor rated cable. In most ap-
plications, the cable will need to be shortened. Follow the wiring instructions below:
1. Turn off AC power to the Pro Logic or Aqua Logic
2. Run the cable through the conduit from the remote mounting location to the Pro Logic/Aqua
Logic.
3. Route the cable through one of the knockouts on the left side of the Pro Logic/Aqua Logic. If
the cable needs to be shortened, cut the cable to length.
4. Strip back the gray jacket and strip each of the 5 conductors to expose 1/8” bare wire.
5. Connect wires to the 4 position terminal block located on the upper left corner of the printed
circuit board. Refer to the “Wiring Configurations” section and follow the wiring diagram
below. Note that the White wire is connected to the screw terminal labeled “Yellow”.
6. Turn on power to the Pro Logic/Aqua Logic.
To Spaside Remote
Black
Red
Yellow
Green
Configuration A
Black
Black
Red
Red
Yellow
Yellow
Green
Green
Configuration B
Configuration C
green
green
green
white
white
white
black
black
black
red
red
red
brown
brown
brown
(not used)