08/18
Model 2000SMS
Page 4 of 6
Step 5:
The bottle filler is supplied with a power cord. If desired, the power cord may be removed and
the unit may be wired through one of the extra holes in the mounting bracket. Install a supply
line through the bottom as shown in Steps 5 & 6 Diagram by removing the plug from the port
and installing the supplied grommet – for use with 3/8” tubing. If desired, one of the extra
ports in the mounting bracket may be used for the supply inlet instead. Connect the supply
line with a screwdriver stop (not supplied). Double-check supply and electrical locations.
NOTE:
When installing this unit, all pertinent local, state, or federal codes should be adhered
to.
Step 6:
Secure the detached mounting bracket to the wall; a number of mounting holes are provided
to fasten the bracket direct to the wall (see Step 5 & 6 Diagram for mounting hole pattern or
use the mounting bracket itself as a template). Note that the bottle filler weighs approximately
30 pounds. As such, attach the mounting bracket using six 1/8” x 3” zinc-plated steel toggle
bolts (not supplied) in conjunction with six appropriately-sized zinc-plated steel 1/8” fender
washers (not supplied). Use a level to verify horizontal and vertical frame mounting.
Steps 5 & 6 Diagram