background image

 

 

08/18 

Model 2000SMS 

Page 1 of 6 

 

 

 

 

No. 0510000664 (3) 

 

                    

 

1455 Kleppe Lane 

Sparks, NV 89431-6467 

(888) 909-4297 

 

website: 

www.Hawsco.com

 

 

 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 

 
 
 

 
 

 
 
 

 
 

QUICK START REFERENCE 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
© 2018 Haws

®

 Corporation – All Rights Reserved 

HAWS

® 

and other trademarks used

 

in these materials are the exclusive property of Haws Corporation.

Model 2000SMS 

 Bottle Filler with Lifecycle Control 

 

 
INSTALLATION GUIDE

 

NOTE: 

A Class A ground-fault circuit interrupter 

(GFCI) shall be installed in the branch-circuit 
supplying power to this unit. 

CAUTION!

 Prior to making any electrical 

connections, verify with a voltmeter that power 
from the service panel is 

off.

 

SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS 
MODEL, OR REQUIRE REPLACEMENT PARTS, PLEASE CALL: 

 

TECHNICAL SUPPORT: 

1-800-766-5612 

HOURS OF OPERATION:  MON-THURS 7:00a.m. - 4:30p.m PT, FRI 7:00a.m.- 11:00a.m. PT 

 

PARTS LIST:

  1 Bottle Filler, 1 filter cartridge, 1 plastic drain basin, 1 hex key, 1 grommet.

 

RECOMMENDED TOOLS:

 Phillips screwdrivers, level. 

REQUIRED PARTS (NOT SUPPLIED):

  1/2” screwdriver stop, 3/8” tubing (to be used for water 

supply inlet), 6 1/8” x 3” zinc-plated steel toggle bolts, 6 zinc-plated steel 1/8” fender washers. 

PRODUCT INSTALLATION:

 When installing this product, local, state or federal codes should be 

adhered to. This unit is certified for indoor use only. 

SUPPLY LINE:

 Minimum recommended line size is 1/2" IPS with 30-90 PSI (2-6 ATM) flowing 

pressure; supply water is to be cold water supply.  Intended for municipal water only. 

PLUMBING CONNECTIONS:

  Inlet is 3/8” O.D. push-in type fitting. If a waste is desired, the Haws 

6470 retrofit 1-1/4” O.D. waste kit may be used. 
 

ELECTRICAL CONNECTIONS:

 115VAC, 60HZ, approx. 0.14A.  Unit is equipped with a standard 

115VAC plug. 

 

RATED SERVICE FLOW:

 0.5 GPM (2725L/day)  

OPERATING TEMPERATURE:

 35–100

°

F (1.7–37.8

°

C) 

OPERATING PRESSURE:  

30-90 PSI 

FILTER CAPACITY: 

2500 gallons (9460L) or 1 year 

REPLACEMENT FILTER CARTRIDGE

: Electronic Lifecycle Control Filter Model 6423 

 

Summary of Contents for 2000SMS

Page 1: ...er cartridge 1 plastic drain basin 1 hex key 1 grommet RECOMMENDED TOOLS Phillips screwdrivers level REQUIRED PARTS NOT SUPPLIED 1 2 screwdriver stop 3 8 tubing to be used for water supply inlet 6 1 8 x 3 zinc plated steel toggle bolts 6 zinc plated steel 1 8 fender washers PRODUCT INSTALLATION When installing this product local state or federal codes should be adhered to This unit is certified fo...

Page 2: ...cyst reduction may be used on disinfected waters that may contain filterable cysts 4 Use the cardboard inserts from the box to support the unit while preparing for installation by placing unit face down on inserts 5 There is an opening in the bottom of the unit to accommodate a plumbed waste If a plumbed waste is desired the Haws model 6470 retrofit kit may be used Step 1 To open the unit slide th...

Page 3: ...er cartridge from the small box inside the main shipping carton Install the drain basin with grate into the front of the unit see Step 3 Diagram pushing it straight in until the snap latches are fully engaged Step 4 Firmly screw the filter cartridge into the filter head see Step 4 Diagram NOTE the bottle filler will work only if a filter cartridge is installed and its wiring is plugged in see Step...

Page 4: ...top not supplied Double check supply and electrical locations NOTE When installing this unit all pertinent local state or federal codes should be adhered to Step 6 Secure the detached mounting bracket to the wall a number of mounting holes are provided to fasten the bracket direct to the wall see Step 5 6 Diagram for mounting hole pattern or use the mounting bracket itself as a template Note that ...

Page 5: ...ram A If water does not dispense see the Troubleshooting Guide in the Owner s Manual The pressure regulator may need to be adjusted to better complement the input pressure at the installation site see Step 9 Diagram B To do so pull out the adjustment knob and rotate as needed clockwise from the front of the unit decreases flow push knob in when desired flow is achieved Flow rate is factory set to ...

Page 6: ... template onto the front of the bottle filler aligning the top and sides flush with the bottle filler panel see Step 11 Diagram Remove the adhesive backing from the logo plate and carefully place into the window of the alignment template Press firmly to secure the logo plate Remove and discard the cardboard template Step 11 Diagram ...