FACTORY SETUP

The charger is delivered with a factory setup as follows:

Profile: As 

ordered

Output DC cable length: 

3 m

Configuration: As 

ordered

Automatic equalisation: 

No

Delayed start enabled:

No

If no modifications are required, go directly to the section: 

Charging the battery

.

If changes are required, go to the 

Configuration

section. 

CHARGING THE BATTERY

It is now assumed that the charger has been set up as per the
Configuration section. Charging can only begin with a battery of the
appropriate type, capacity and voltage connected to the charger.

Off-charge display

With the charger in  waiting mode, the display shows information 
concerning the charger  (top and bottom lines):
1.

Charger type (

Battery v current

). 

2.

Last selected charging profile.

3.

Software version.

4.

Waiting indication.

5.

Date and time of the charge.

6.

Set up battery operating temperature.

Alternating battery temperature/capacity if the ‘manu’ capacity mode
is selected.

Delayed start

If the charger was programmed for a delayed start (

Configuration

menu/Delayed start), charging will begin following that delay. or at 
the specified time. The display shows the time remaining before the 
programmed charging starts.

Starting a desulphation cycle before charging

Desulphation of a vented battery is started manually, in this case the
charger will consider the configuration in the menu Equalisation with the
current and time set up in the charger menu. To start the desulphation
charge, please proceed as follows.

1.

Connect the battery 

2.

Press the central button      to stop the charger.

3.

Press and hold the button     .

4.

Press the central button      to start the charger. 

Release     .

The standard charging cycle will have to be started  manually after the
desulphation cycle is completed. 

Initiating the equalisation charge after a standard 
charge

An equalisation charge can be programmed at the end of charge when 

the user presses the button      during the standard charge or when the
battery is available. The equalisation symbol appears on the top, left side
of the display. The equalisation current is defined by the charger.

Starting the charge
1.

If Autostart = On (default ON), the charge starts automatically when
the battery is connected to the charger. To stop the charge, press
the central button     . 
If Autostart = OFF the charge will start only if the central button is
pressed. To stop the charge, press the central button     .

The displays shows information relative to the connected battery
and counts down the time remaining until the effective charge
begins. 

Ref.

Without Wi-IQ

®

With Wi-IQ

1.

Charger status (CHARGE, AVAIL, DEFAULT, EQUAL..), possible
pump fault or DF4. 

2.

Alternating display of battery voltage, voltage per cell, Ah 
restored, charging time, remaining charging time, percentage 
of battery charge.

3.

Set up operating battery T°C,

Battery temperature and

and battery capacity if manual 

capacity given by the Wi-IQ

mode set.

(*).

4.

Charging current

5.

Programmed charging profile.

Detected charging profile (*).

6.

Various information can be displayed: equalisation symbol 
required at the end of charge, USB connection symbol, Wi-IQ link
symbol, possibly battery default DF4.

7.

Empty line.

Alternating, detected serial
number, as information is
received and alarms if 
present. See § 

Fault codes

.

(*) as information is received.

As soon as the countdown time has elapsed, the display shows the 
information relative to the charge.

To induce the start of the charge if the delayed charge has been pro-
grammed:

1.

Connect the battery 

2.

Press the central button      to stop the charger.

3.

Press and hold the central button      for 3 seconds. Release.

Defaults 

DF1, DF2, DF3

and 

TH

inhibit the charge. Refer to section 

Fault

codes

.

End of charge without equalisation
1.

The backlight of the screen becomes green at the end of a correct
charge. 

And the indication 

AVAIL

is displayed. Possible alternating display

between DF5 default and pump default and DF4 (ref.1). The displays
shows alternately: (ref. 2):
•  charging time achieved.
•  number of Ah restored.

Refer to sections 

Memorisations

or 

Status

for detailed information

relevant to the end of charge.

If the battery remains connected, and in order to maintain it in a
fully charged condition, refresh charges followed by equalisation
charges will be automatically initiated according to the battery 
technology.

2.

If an equalisation charge has been programmed (vented battery), it
will start automatically.

Alternatively, an equalisation charge can be

triggered manually; go to section 

End of charge with equalisation

.

3.

Press the central button or disconnect the battery that is now ready
for use.

End of charge with equalisation

Equalisation only applies to vented batteries. Start can be manual or
automatic.

Manual start
1.

At the end of charge (green lighted display on), press the key     . 

The start of the equalisation charge is indicated by the message

EQUAL

. During the equalisation charge, the charger displays the 

current (ref 4) and alternating, the battery voltage, voltage per cell,
remaining time (ref 2).

2.

The battery will be available as soon as the screen becomes green.

8

010

WAIT

012

Summary of Contents for Life IQ

Page 1: ...1 Technical Manual GB Hawker Life IQTM Single phase and 3 phase chargers ...

Page 2: ...irectly in contact with water Must be used only within the temperature range specified in the technical specifications Internal connection torques must be checked once a year Must not be installed on a surface subject to high vibration levels proximity of motors compressors etc Must not be installed close to the batteries in order to avoid any gassing that could damage it prematurely Must not be i...

Page 3: ...ansmits battery parameters to the charger in order to optimise the charge and to manage the charge and discharge data Communicated parameters are Temperature battery capacity warnings water level voltage balance voltage charging status The Wi IQ also transmits data of the battery temperature during the charging process and will possibly stop the charge if the temperature is too high Charging profi...

Page 4: ...m for safe disconnection during the charge A USB interface enables the connection of a USB stick to download all data stored in the charger optionally fitted with Ethernet interface for remote management of the charger EXTERNAL COMPONENTS Presented below Single phase model 3 phases model Ref Function 1 Ventilation louvres 2 Display and control panel 3 AC input cable 4 Battery cable 5 Wall mounting...

Page 5: ...e battery temperature will be analysed during the charge if it increases too much the charger will stop to prevent any possible damage High temperature Defines the safety limit in high temperatures Without Wi IQ not used With Wi IQ If the battery temperature during the charge reaches the programmed limit the charger will stop the charge and wait until the temperature decreases Charge Profile For s...

Page 6: ... Region Selects the format for date metric imperial units for temperature and length Contrast Modifies the display contrast level Change Password Changes the password PASSWORD Manages a password to limit access to charger menu INFORMATION Gives information on the software version memory and time clock USING THE CHARGER UNPACKING The charger is delivered with the following 2m AC mains cable 3m DC b...

Page 7: ... be 230V AC single phase or 400V AC 3 phase and must be connected using a suitable plug and adequately sized circuit breaker not included Current requirements in Amps are indicated on the charger information plate Battery output It is essential to ensure correct polarity However reversed polarity will result in blowing the output fuse inability to charge and the fault code DF2 to be displayed See ...

Page 8: ...to the connected battery and counts down the time remaining until the effective charge begins Ref Without Wi IQ With Wi IQ 1 Charger status CHARGE AVAIL DEFAULT EQUAL possible pump fault or DF4 2 Alternating display of battery voltage voltage per cell Ah restored charging time remaining charging time percentage of battery charge 3 Set up operating battery T C Battery temperature and and battery ca...

Page 9: ...vel DF PUMP Fault in the air circuit Check the proper operation of of the electrolyte the pump via the menu circulation system Option Option test Check the air circuit pump tubes If this fault occurs the charger will adapt the battery charging profile for a safe optimised charge TH Thermal problem in Verify the correct operation of charger resulting in the fans check for too high charge interrupti...

Page 10: ...closely with our customers and suppliers to identify development opportunities Our bias for rapid innovation means we get new products to market fast EnerSys s integrated sales and service network is dedicated to providing our customers with the best solutions and after sales support for their business Whether you require 1 battery or a complete fleet of batteries chargers a battery handling syste...

Reviews: