Page 5
Section - 3
EMERGENCY PROCEDURES
FAA Approved
Original Issue: Feb 28, 2006
Hawker 850XP Pro Line 21 Airplane Flight Manual
ENGINE FIRE ON GROUND
GEN .............................................................................TRIP
BUS TIE (if open) .........................................................CLOSE
WHEEL BRAKE lever ..................................................PARK
After 30 seconds, if ENG FIRE remains illuminated:
ENG EXT (affected engine) .........................................SHOT 2
Other HP COCK...........................................................Close
Other LP COCK ...........................................................Close
Fuel pumps ..................................................................Both OFF
If Necessary, Complete EMERGENCY EVACUATION procedure - this section.
NOTES:
1. The fire extinguisher second shot is only available if generated power or external
power is supplied.
2. Closing the No. 1 LP Cock will automatically shut down the APU (if installed) if it
is running.
3. Do not attempt to restart the engine after a fire warning.
START PWR switch (starting only) ..................... PUSH FOR ABORT
HP COCK (affected engine) ................................. Close
LP COCK (affected engine).................................. Close
ENG EXT (affected engine) .................................. SHOT 1
ENG 1
FIRE
ENG 1
FIRE
or
Fire Bell Sounds and
ENG 2
FIRE
ENG 2
FIRE
Fire Bell Sounds and
or
For Training Purposes Only