The transducer must be above the maximum head by at least the near blanking dis-
tance.
In the case of a Palmer Bowlus flume the point of head measurement should be half
the value of Dim “A” upstream of the device.
For a H-Flume the head measurement is taken at a point downstream from the flume
entrance as detailed in the table below:
137.15
4.5
40.5
16.19
15.25
0.5
4.7
1.88
23.00
0.75
6.7
2.69
30.05
1.0
9.1
3.63
45.70
1.5
13.5
5.38
61.00
2.0
17.9
7.19
76.20
2.5
22.5
9.00
91.45
3.0
27.2
10.88
Flow (q)
Point of
measurement
(see table)
Transducer mounted
minimum blanking distance
(p107) above max. head
DRWG 15
Flume size
Point of Measurement
Dim “A” P710
cm
feet
cm
feet
H-Flume