BS3680 RECTANGULAR WEIR
In this example it is required to calculate to the flow through a BS3680 Rectangu
-
lar weir. Absolute calculation will be used. The flow rate is required to be displayed
in litres/minute and the totaliser is to record the flow in cubic metres.
The distance from the end of the transducer horn to zero flow is 1 metre and max
head is 0.4 metres, maximum flow.
Approach width (Dim”A”) = 0.5 m
Crest width (Dim “B”) = 0. m
Crest Height (Dim “C”) = 0. m