Sultan Flow Series
MANUAL
Draft 1.2, Mar 2009
14
15
BS3680 U-Throated Flume
In this example it is required to calculate
to BS3680 the flow through a U-Throated
Flume without any hump.
Absolute
calculation will be used. The flow rate is
to be displayed in cubic meters/hour and
the totaliser is also to record the flow in
cubic metres.
The distance from the end of the trans-
ducer to zero flow is 1 metre and max
head is 0.4 metres, maximum flow.
The dimensions of the flume are as fol
-
lows:
Approach Channel diameter
(Dim “A”)
= 0.7 m
Throat diameter (Dim “B”) = 0.5 m
Throat length (Dim “C”)
= 1.0 m
Summary of Contents for Sultan Flow Series
Page 1: ...INSTRUCTION MANUAL SULTAN FLOW Acoustic Wave Technology A higher level of performance DRAFT ...
Page 11: ...11 Sultan Flow Series MANUAL Draft 1 2 Mar 2009 ...
Page 13: ...13 Sultan Flow Series MANUAL Draft 1 2 Mar 2009 BS3680 FLUMES ...
Page 16: ...Sultan Flow Series MANUAL Draft 1 2 Mar 2009 16 BS3680 RECTANGULAR WEIR ...
Page 18: ...Sultan Flow Series MANUAL Draft 1 2 Mar 2009 18 BS3680 Thin Plate Weirs ...