76
4000414930
E 10.15
USA / GB
Upper boom
Condition of the cables inspection - Criteria of replacement
MS0012
4 - Tension checking
This operation must be realized as of the first 50 hours, then :
• for STAR all 250 hours or 3 months.
• for the other machines all 250 h hours or 6 months.
For the particular procedures of adjustment untreated in maintenance book, it is necessary to contact HAULOTTE
Services®.
MS0018 Boom adjustment procedure.
5 - Criteria of replacement
Cables with a diameter measuring less than 6 mm (STAR) must be replaced every 5 years.
All other cables must imperatively be replaced every 7 years.
Replacement may be required more frequently for the following reasons :
• Machine operates in a particularly hostile environment.
• Abnormal noises are produced during movement of structure.
• Machine has been in storage for more than 6 months.
• Machine has been submitted to an abusive load or serious collision.
• Machine has been exposed to an electrical arc.
Contact Haulotte Services for further advice.
Cables and cable elements are made from case hardened steel in a high-quality process. Deliver any scrap cables or
cable elements to a dealer specialised in metal recycling in compliance with regulations.
Summary of Contents for STAR 10
Page 2: ...2 4000414930 E 10 15 USA GB STAR 8 STAR 22J STAR 10 STAR 26J ...
Page 10: ...10 4000414930 E 10 15 USA GB STAR 8 STAR 22J STAR 10 STAR 26J A Preface Foreword Notes ...
Page 18: ...18 4000414930 E 10 15 USA GB STAR 8 STAR 22J STAR 10 STAR 26J B Safety Notes ...
Page 32: ...32 4000414930 E 10 15 USA GB STAR 8 STAR 22J STAR 10 STAR 26J C Familiarization Notes ...
Page 62: ...62 4000414930 E 10 15 USA GB General data Breaking test procedure MS0004 Notes ...
Page 66: ...66 4000414930 E 10 15 USA GB General data Torque Values MS0005 Notes ...
Page 72: ...72 4000414930 E 10 15 USA GB Chassis and turntable Slew ring inspection MS0010 Notes ...
Page 80: ...80 4000414930 E 10 15 USA GB Electric Electrical wiring MS0059 Notes ...
Page 116: ...116 4000414930 E 10 15 USA GB Hydraulics Hydraulic filter cartridge Replacement MS0050 Notes ...
Page 124: ...124 4000414930 E 10 15 USA GB Electric Battery ies MS0051 Notes ...
Page 144: ...144 4000414930 E 10 15 USA GB Mast Inspection of the slack chain sensors MS0062 Notes ...
Page 148: ...148 4000414930 E 10 15 USA GB Overriding system Overriding function reset MS0085 Notes ...