- Trouble shooting and diagram
Failure
Code
C
Description
F01 : Inverter
Low
Battery
F01.08 (A)
1
Low battery voltage (estimated value < 10%).
Check for damaged batteries, battery cables or connections.
Recharge batteries.
Measure batteries voltage and compare it with the value BATTERY VOLTAGE parameter in
the TESTER menu.
If they are different, adjust the value of the ADJUST BATTERY function.
Electrical
park brake
1
F01.09 (A)
1
COMBIACX : Short circuit detected on electromechanical brake or main contactor output
(overcurrent).
Main contactor drive coil : Check connections and wiring for interruptions between controller
and coil.
Motor brake coil : Check connections and wiring for interruptions between controller coil.
If the wiring is correct, the problem is in the controller : Replace it.
2
COMBIACX : The driver of the electromechanical brake coil is shorted.
Check if there is a short or a low impedance pulldown between NEB CNA#4 and -BATT. The
driver circuit is damaged in the controller, which has to be replaced.
4
COMBIACX : The driver of the electromechanical brake is shorted to +Vbatt.
The output of the built in Smart Driver, which supplies the positive to the electromechanical
brake coil is high when the Tiller and the H&S switch are opened.
Check the harness, in order to verify if a positive is connected to the Smart driver output
CNB#1.
If, even disconnecting the wire from the connector pin, the output stays at high value, the
problem is inside the controller and the Smart Driver is probably shorted.
8
COMBIACX : A short circuit on the power outputs of the controller has been detected.
Check the EB driver output for a short circuit with +Vbatt.
If, even disconnecting the wire from the connector pin, the output stays at high value, the
problem is inside the controllerReplace it.
16
COMBIACX : Voltage on PEB present but not expected.
Check external wiring.
If the wiring is correct and no problem is found on the coil, replace the controller.
32
COMBIACX : internal Smart driver KO and ACEX : internal Smart driver is not KO (if both
signals are KO => failure F08.10).
Check the driver output for a short circuit with -Vbatt.
If, even disconnecting the wire from the connector pin, the output stays at low value, the
problem is inside the controller : Replace it.
Summary of Contents for OPTIMUM 1931 E
Page 2: ...2 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E...
Page 10: ...10 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E A Preface Foreword Notes...
Page 19: ...19 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E C Familiarization Familiarization Notes...
Page 54: ...54 4000429690 E 11 15 US GB General data Structural part inspection MS0001 Notes...
Page 64: ...64 4000429690 E 11 15 US GB General data Breaking test procedure MS0004 Notes...
Page 72: ...72 4000429690 E 11 15 US GB Electric Electrical wiring MS0025 Notes...
Page 76: ...76 4000429690 E 11 15 US GB Scissor arm Scissor arms screw Periodical checks MS0073 Notes...
Page 88: ...88 4000429690 E 11 15 US GB Platform Removal replacement of platform assembly MS0095 Notes...
Page 98: ...98 4000429690 E 11 15 US GB Scissors Removal replacement of Scissor pack MS0096 Notes...
Page 102: ...102 4000429690 E 11 15 US GB Chassis Calibration steering MS0097 Notes...
Page 116: ...116 4000429690 E 11 15 US GB Ground control box HAULOTTE Activ Screen MS0106 Notes...
Page 135: ...135 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E E Trouble shooting and diagram...
Page 136: ...136 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E E Trouble shooting and diagram...
Page 138: ...138 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E E Trouble shooting and diagram Notes...
Page 148: ...148 4000429690 E 11 15 US GB OPTIMUM 8 OPTIMUM 1931 E F Records...