7 Troubleshooting
15
7
Troubleshooting
Error
Cause
Measure for elimination
The ionizing unit is dirty.
Clean the ionizing unit.
Check power pack.
No ionization
No high voltage.
Check connections.
The ionizing unit is
covered with an
electrically conductive
deposit.
Clean the ionizing unit.
The ionizing pins are too
close to an electrically
conductive material.
Increase distance to the
cause.
Sparks-over
The ionizing unit is
damaged.
Switch off the
MJ II
automatically and secure
against switching on.
NOTE:
If the error cannot be removed in
this way, return the power pack and
MJ II
for checking to HAUG GmbH & Co. KG
(for address, see reverse).