4
L / M . . / 07.96
Trouble-shooting table for electrical system
Trouble-shooting at the battery
Malfunction
Rate of charge never
adequate.
Indication
Terminal voltage soon
drops to 7 V after
recharging (12 V
nominal voltage) or to
14 V (24 V nominal
voltage).
Cause
Fault in generator, volta-
ge regulator or wiring
connections.
V-belt too loose.
To many consumers
connected or generator
is too small.
Remedy
Repair or renew gene-
rator and voltage regu-
lator. Connect wiring
firmly.
Corret tension or renew
V-belt
Install battery and
generator with similar
ratings.
Summary of Contents for 2-4L30
Page 2: ......
Page 6: ......
Page 7: ...1 L M 10 98 1 General...
Page 22: ......
Page 23: ...2 L M 09 96 2 Additional equipment...
Page 47: ...3 Basic engine 3 L M 09 96...
Page 134: ......
Page 135: ...4 L M 07 96 4 Tables...