36
IND100064-35
Operation
User Controls
USER CONTROLS OVERVIEW
The units are designed by using Glass Display Control
™
(GDC) touch technology to allow interactivity adjusting
brilliance (brightness) and control power on / off with the use of illuminated symbols. Note that these symbols are
only visible (backlight illuminated) when suitable power is connected. There is no physical moving knobs, potmeters,
wheels or push buttons available as everything is touch surface controlled by Projected Capacitive
technology, that allows a human finger (including several types of gloves) to control the unit.
Light Sensor
Brightness adjust Power On/Off + Status
Action Indicators ECDIS Status / Indicator
Light Sensor:
Used to sense level of ambient light in the surrounding environment. The sensor data can be read by suitable software
through the Hatteland Display SCOM functionality of the unit and thus can be used to control brightness remotely.
Note: This sensor is not visible for the eye or has any illumination behind to indicate it’s position. Further, by touching
or covering this area will naturally make the sensor data inaccurate.
Action Indicators:
HDD
= Whenever there is a storage device activity (HDD/SSD read or write operations) this area will
illuminate and blink accordingly in sync. with the read/write operations while the unit is powered.
Note that by touching this symbol no action will be performed or has been assigned.
SERVICE
= Built in functionality to determine when the unit requires service in order to perform within preset
factory standards. This area will illuminate constantly until the unit is powered off.
Note that by touching this symbol no action will be performed or has been assigned.
Brightness Adjust:
Brilliance / Brightness adjustment of the displayed image is adjusted by touching the (-) or (+) illuminated symbols.
The entire area of text and symbols are visible as long as the unit is powered. Note that only the (-) and (+) are touch
sensitive while the “*” and “BRILLIANCE” symbols are not.
ECDIS Status / Indicator:
(optional factory standard)
For units that has been factory ECDIS calibrated the text “ECDIS” will illuminate in green constantly as long as the
unit is powered. The “+” and “-” symbols will illuminate in red when the Brightness/Brillance is adjusted either above or
below ECDIS factory calibration point.
To be able to stay within ECDIS calibrated range, please assure that both the “+” and “-” are not illuminated and that
“ECDIS” text remains illuminated during operation. Note that by touching these symbols no action will be performed or
has been assigned.
Summary of Contents for HD 12T21 STD-xxx-Fxxx
Page 7: ...7 General...
Page 17: ...17 Installation...
Page 34: ...34 This page left intentionally blank...
Page 35: ...35 Operation MMC Products...
Page 38: ...38 This page left intentionally blank...
Page 39: ...39 Specifications...
Page 51: ...51 Specifications Accessories...
Page 55: ...55 Technical Drawings...
Page 62: ...62 This page left intentionally blank...
Page 63: ...63 Technical Drawings Accessories...
Page 71: ...71 Appendixes...
Page 88: ...88 IND100077 24 Appendix User Notes...
Page 90: ...www hatteland display com...