HATO 400Y Manual Download Page 11

Hold the 

SETUP

 button again within 3 seconds.

Pressing is signaled by continuous lighting of the

diode.

                   

                

The 

LED

 will flash rapidly.

Release the 

SETUP

 button.

 

After releasing the button, the 

LED

 will show the

current status of the function. The lighted on

means the function is active, and the light off

means the function is inactive.

 

To change the state of the function to the opposite,

press the 

SETUP

 button briefly within 

3 seconds

.

 

 

After 

3s 

from the last press, the 

LED

 will flash 

3

times. The controller will remember the settings

and return to normal operation.

 

AUTOCLOSE FUNCTION

When the gate stops, after the OPEN signal, the time set by the user is counted down, after which the
CLOSING will take place. The light shines during the countdown. For the user's safety, photocells are

required (so that the gate does not close when there is an obstacle in its light!). Additionally, when the

PHOTO CLOSE

 function is on, the photocells will shorten the auto-closing time and after detecting the

passage, the gate will close after 5 seconds. If less than 5s are left until automatic closing, each
detected passage will cause the countdown of an additional 5s. If the gate is in the fully open position,

each signal trying to activate it in the opening direction will start the countdown of the auto-closing
time.

ATTENTION!

 

Stopping   the   gate   with   a   transmitter   or   control   button   during   closing   stops   the

countdown. Therefore, to close the gate, press the control button again - you can use it when you

need to leave the gate open for some time.

To 

turn on

 the function, set the 

AUTO CL

 switch to

the 

ON

 position.

           

Set the desired auto-closing time according to the

procedure.

SETTING THE AUTO-CLOSING TIME

To 

disable

 the function, set the 

AUTO CL 

switch to

the 

OFF

 position.

           

SETTING THE AUTO-CLOSING TIME

We set it in the range from 

15s

 to 

25min

 with a step of 15s. By default: 

6min

The 

AUTO CL

 switch must be in the 

ON

 position.

         

Hold down the 

SETUP

 button for less than 

3s

.

When the button is pressed, the 

LED

 lights up.

 

Release the 

SETUP

 button.

The 

LED

 will flash rapidly.

Summary of Contents for 400Y

Page 1: ...HATO 400Y AUTOMATION MANUAL FOR SLIDING GATES WITH SLOW DOWN...

Page 2: ...he controller uses 230Vac voltage life and health threatening All works related to the proper functioning of the device connection start up operation must be carried out in accordance with the applica...

Page 3: ...This note also applies to waste batteries and accumulators TABLE OF CONTENTS RECOMMENDATIONS AND PRECAUTIONS 2 2 IMPORTANT SAFETY INSTRUCTIONS 4 DESCRIPTION AND PRINCIPLE OF THE OPERATION OF THE CONT...

Page 4: ...r installed which automatically turns off the engine at 120 C and turns it on when the temperature drops to 85 C 5 C The applied system of rolling coding of Microchip remote controls makes the system...

Page 5: ...3 MOUNTING OF THE LIMIT SWITCH CAMS Fig 3...

Page 6: ...available to an unauthorized person CONTROLLER ADVANTAGES Soft start function increasing the life of the door Control by means of remote control transmitters up to 28 pcs On the frequency of 433 92 MH...

Page 7: ...te version of the controller DRIVER INSTALLATION Before starting the installation make sure that all safety recommendations are met Any installation work may only be performed by qualified personnel E...

Page 8: ...required greater distances 4x0 5 mm cables can be used by connecting the wires in parallel in pairs or by increasing the cross section of the cable 2x 1mm 15 SBS bell button 18 COM 1 4 Pulse generato...

Page 9: ...ning direction Otherwise swap the wires connected to the OPEN 11 and CLOSE 8 connectors after disconnecting the power supply first 7 Set potentiometer VR1 turning clockwise increases the value on the...

Page 10: ...LIGHT OFF DELAY We set it in the range from 0s to 25min with a step of 15s Default 0s If the AUTO CLOSE function is enabled set the AUTO CL switch to the OFF position Hold down the SETUP button for le...

Page 11: ...ls will shorten the auto closing time and after detecting the passage the gate will close after 5 seconds If less than 5s are left until automatic closing each detected passage will cause the countdow...

Page 12: ...ust on the VR1 potentiometer in accordance with the applicable standards Hold down the SETUP button The LED will turn on and then turn off Release the SETUP button If the gate is in the fully closed p...

Page 13: ...rol button for less than 3s or the transmitter button assigned to the SBS function or SBS The gate will start to close for work without an encoder with the power set on the VR1 potentiometer The LED w...

Page 14: ...h slowly CL Hold down the SETUP button The LED will blink 3 times Release the SETUP button The controller will return to normal operation WICKET FUNCTION It allows the door to be partially opened to t...

Page 15: ...BS sequence control button for less than 3s or the transmitter button assigned to the SBS function or SBS The gate will stop The LED will turn off Press the SBS sequence control button for less than 3...

Page 16: ...ter changing a parameter retry the learn procedure We set it in the range from 0 1s to 1s with 0 1s step Default 0 3s Przytrzymaj przycisk SETUP SETUP The LED will turn on turn off turn on and turn of...

Page 17: ...itch to the OFF position DELETING ALL TRANSMITTERS When the memory is full or we have problems with programming the transmitters we must perform the deletion procedure We recommend that you perform th...

Page 18: ...within 10 seconds Correct programming will be signaled by the LED blinking three times 2 blinks indicate full memory 1 blink means the end of the learning time After correct programming we have anothe...

Page 19: ...HEL11 8 2 2 Standby power consumption 4 5 VA Remote control type E Keeloq version HP 001 1 piece Remote control operating frequency 433 92 MHz with rolling code Min Range of the remote control in open...

Page 20: ...zed activities aimed at removing a defect in a device covered by the warranty According to the opinion of the HATO service the device or components in which material construction or production defects...

Page 21: ...n unsuccessful four times 5 The buyer is obliged to notify the seller about the defect within 2 days from the date of its disclosure 6 This warranty covers only HATO products installed and used in Pol...

Page 22: ...HATO POLSKA SP Z O O...

Page 23: ...ul Tunelowa 57 40 676 Katowice POLAND tel 032 785 25 42 www hato pl Magazyn i sprzeda ul eromskiego 1 41 205 Sosnowiec DISTROBUTOR SELLER...

Reviews: