This manual provides the installation, safety, and operating 

instructions for Hatco Induction Ranges. Hatco recommends 

all installation, operating, and safety instructions appearing in 

this manual be read prior to installation or operation of a unit. 
Safety information that appears in this manual is identified by 

the following signal word panels:

WARNING

WARNING indicates a hazardous situation which, if not 

avoided, could result in death or serious injury.

CAUTION

CAUTION indicates a hazardous situation which, if not 

avoided, could result in minor or moderate injury.

NOTICE

NOTICE is used to address practices not related to personal 

injury.

INTRODUCTION

Hatco Induction Ranges offer a safe, quick, efficient, and 

attractive way to prepare foods in commercial kitchens as 

well as display cooking locations (omelet bars, buffets, etc...). 

The high efficiency, accuracy, and speed of induction cooking 

make Hatco Induction Ranges the perfect choice for quality 

foodservice organizations.
Induction cooking relies on the creation of a magnetic field 

between the induction coils below the glass surface of the 

unit and an “induction-ready” pan sitting on top of the glass 

surface. This magnetic field generates induction currents in 

the base of the pan, which heat the pan instantly. That heat 

then is transferred to the pan contents. Since the magnetic field 

exists only between the induction coils and a magnetic material 

(ferrous material), the glass surface between the two does not 

become heated, eliminating heat loss and increasing efficiency. 

When the magnetic field is “broken” by turning off the unit or 

removing the pan, heat generation stops instantly.
Hatco Induction Ranges are products of extensive research and 

field testing. The materials used were selected for maximum 

durability, attractive appearance, and optimum performance. 

Every unit is inspected and tested thoroughly prior to shipment.

Important Owner Information ..............................................2

Introduction ...........................................................................2

Important Safety Information ..............................................3

Model Description ................................................................4

Model Designation ...............................................................4

Specifications .......................................................................5

Plug Configurations .............................................................5

Electrical Rating Chart .........................................................5

Dimensions  .........................................................................5

Installation .............................................................................6

General ................................................................................6

Operation ...............................................................................7

General ................................................................................7

Using the Timer ...................................................................8

Updating Firmware ..............................................................8 

Maintenance ..........................................................................9

General ................................................................................9

Daily Cleaning .....................................................................9

Cleaning the Air Inlet Filter ..................................................9

Troubleshooting Guide ......................................................10

Limited Warranty ................................................................ 11

Service Information ............................................................ 11

Authorized Parts Distributors .............................Back Page

IMPORTANT OWNER INFORMATION

Record the model number, serial number, voltage, and purchase 

date of your strip heater in the spaces below (specification 

label located on the underside of the unit). Please have this 

information available when calling Hatco for service assistance.
Model No. ________________________________________
Serial No. _________________________________________
Voltage ___________________________________________
Date of Purchase ___________________________________

Register your unit!

Completing online warranty registration will prevent delay in 

obtaining warranty coverage. Access the Hatco website at 

www.hatcocorp.com

, select the 

Parts & Service

 pull-down 

menu, and click on “Warranty Registration”.

Business

Hours: 7:00 

am

 to 5:00 

pm

 Central Standard Time (CST)

 

(Summer Hours:  June to September

 

 7:00 

am

 to 5:00 

pm

 CST Monday

Thursday 

 7:00 

am

 to 4:00 

pm

 CST Friday)

Telephone: 800-558-0607;  414-671-6350
E-mail: [email protected]

24 Hour 7 Day Parts and Service

Assistance available in the United States

and Canada by calling 800-558-0607.

Additional information can be found by visiting our web site at 

www.hatcocorp.com

.

This device complies with Part 18 of the FCC Rules.

Summary of Contents for Rapide Cuisine IRNG Series

Page 1: ...al menos que haya le do y comprendido el contenido de este manual Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesi n o muerte Este manua...

Page 2: ...tion Ranges are products of extensive research and field testing The materials used were selected for maximum durability attractive appearance and optimum performance Every unit is inspected and teste...

Page 3: ...fied electrician to determine and install proper voltage and size electrical receptacle Turn OFF power unplug power cord and allow unit to cool before performing any cleaning adjustments or maintenanc...

Page 4: ...tilation system ensures that the electronic circuits in the unit do no overheat Temperature probes monitor the electronic circuits and will signal the unit to shut down if the circuits get too hot A r...

Page 5: ...not match contact a qualified electrician to determine and install proper voltage and size electrical receptacle NEMA 5 15P NEMA 5 20P Plug Configurations NOTE Receptacle not supplied by Hatco All uni...

Page 6: ...flow to air intake or exhaust openings on sides or bottom of unit Locate unit at proper counter height in an area that is convenient for use Location should be level to prevent unit or its contents fr...

Page 7: ...the unit will not start until the unit gets hot Once the fan turns on it will run until the unit cools 2 Plug the unit into a properly grounded electrical receptacle of the correct voltage size and p...

Page 8: ...Control screen appears showing a bar graph and a percentage of power setting 2 Push and hold the Control Knob for approximately 6 8 seconds A password screen will appear To enter the 3 digit password...

Page 9: ...contact the Hatco Service Department at 800 558 0607 or 414 671 6350 CAUTION Use only wipes pads and cleaners designed specifically for cleaning ceramic glass surfaces Wipe up all spills and splashes...

Page 10: ...e Pan Specifications in the OPERATION section of this manual Troubleshooting Questions If you continue to have problems resolving an issue please contact the nearest Authorized Hatco Service Agency or...

Page 11: ...sapplication improper installation or application of improper voltage 2 LIMITATION OF REMEDIES AND DAMAGES Hatco s liability and Buyer s exclusive remedy hereunder will be limited solely at Hatco s op...

Page 12: ...la suppression du r cipient la production de chaleur cesse instantan ment Les cuisini res induction d Hatco sont le r sultat de recherches approfondies et d essais sur le terrain Les mat riaux utilis...

Page 13: ...R DE D CHARGE LECTRIQUE Branchez l appareil une prise de courant mise la terre et pr sentant la tension la taille et la configuration ad quates Si la fiche et la prise ne se correspondent pas adressez...

Page 14: ...r la surchauffe des circuits lectroniques de l appareil Des sondes de temp rature surveillent les circuits lectroniques et envoient un signal l appareil lorsque ce dernier doit s teindre dans le cas o...

Page 15: ...application AVERTISSEMENT DANGER DE D CHARGE LECTRIQUE Branchez l appareil une prise de courant mise la terre et pr sentant la tension la taille et la configuration ad quates Si la fiche et la prise...

Page 16: ...s sur les c t s et en dessous de l appareil Placez l appareil sur un plan de travail dont la hauteur est appropri e un emplacement pratique utiliser L emplacement doit tre horizontal pour viter que l...

Page 17: ...an de commande et l appareil ne fonctionnera pas Mise en service 1 Chaque jour avant d allumer l appareil nettoyez la plaque de cuisson en vitroc ramique l aide d une lingette nettoyante d un papier a...

Page 18: ...chant DONE Termin puis 0 00 00 Le r glage de la puissance se met sur 0 Mise jour du micrologiciel Respectez la proc dure suivante pour t l charger les mises jour du micrologiciel de la plaque inductio...

Page 19: ...de Hatco au 800 558 0607 ou 414 671 6350 ATTENTION Utilisez uniquement des chiffons lingettes et produits nettoyants con us sp cifiquement pour nettoyer des surfaces en vitroc ramique essuyez les d ve...

Page 20: ...uvent provoquer des d charges lectriques et des br lures AVERTISSEMENT DANGER DE D CHARGE LECTRIQUE Mettez hors tension l appareil d branchez le cordon d alimentation et laissez l appareil refroidir a...

Page 21: ...TOUTES AUTRES ATTEINTES AUX DROITS DE LA PROPRI T INTELLECTUELLE Sans restreindre la port e g n rale des nonc s pr c dents CES GARANTIES NE COUVRENT PAS LES L MENTS SUIVANTS ampoules d clairage incand...

Page 22: ...Formulaire n IRNGHM 0117 22 Fran ais NOTAS...

Page 23: ...English Form No IRNGHM 0117 23 NOTES...

Page 24: ...arts Service St Louis 314 535 2222 NEBRASKA Anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEY Jay Hi...

Reviews: