background image

English

Form No. IRNGHM-0117

5

Model

Voltage

Watts

Amps

Plug Configuration Shipping Weight

IRNG-HC1-14

120

1440

12

NEMA 5-15P

17 lbs. (8 kg)

IRNG-HC1-18

120

1800

15

NEMA 5-15P

*

17 lbs. (8 kg)

SPECIFICATIONS

Electrical Rating Chart 

Plug Configurations

Units are supplied from the factory with an electrical cord and 

plug installed. Plugs are supplied according to the application.

WARNING

ELECTRIC SHOCK HAZARD: Plug unit into a properly 

grounded electrical receptacle of the correct voltage, 

size, and plug configuration. If plug and receptacle do not 

match, contact a qualified electrician to determine and 

install proper voltage and size electrical receptacle.

NEMA 5-15P

NEMA 5-20P

Plug Configurations 

NOTE: Receptacle not supplied by Hatco. All units must be 

connected to a dedicated circuit.

NOTE: The specification label is located on the bottom of the 

unit. See label for serial number and verification of unit 

electrical information.

*

 NEMA 5-20P for Canada.

NOTE: Shipping weight includes packaging.

Dimensions

A

C

12-1/16"

(307 mm)

12-3/16"

(310 mm)

B

E

D

Front View

Side View

Top View

Model

Width (A)

Depth (B)

Height (C)

Footprint Width (D)

Footprint Depth (E)

IRNG-HC1-14

13ʺ

(330 mm)

17ʺ

(431 mm)

3-7/16ʺ

(86 mm)

12ʺ

(304 mm)

13-3/8ʺ

(339 mm)

IRNG-HC1-18

13ʺ

(330 mm)

17ʺ

(431 mm)

3-7/16ʺ

(86 mm)

12ʺ

(304 mm)

13-3/8ʺ

(339 mm)

Summary of Contents for Rapide Cuisine IRNG Series

Page 1: ...al menos que haya le do y comprendido el contenido de este manual Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesi n o muerte Este manua...

Page 2: ...tion Ranges are products of extensive research and field testing The materials used were selected for maximum durability attractive appearance and optimum performance Every unit is inspected and teste...

Page 3: ...fied electrician to determine and install proper voltage and size electrical receptacle Turn OFF power unplug power cord and allow unit to cool before performing any cleaning adjustments or maintenanc...

Page 4: ...tilation system ensures that the electronic circuits in the unit do no overheat Temperature probes monitor the electronic circuits and will signal the unit to shut down if the circuits get too hot A r...

Page 5: ...not match contact a qualified electrician to determine and install proper voltage and size electrical receptacle NEMA 5 15P NEMA 5 20P Plug Configurations NOTE Receptacle not supplied by Hatco All uni...

Page 6: ...flow to air intake or exhaust openings on sides or bottom of unit Locate unit at proper counter height in an area that is convenient for use Location should be level to prevent unit or its contents fr...

Page 7: ...the unit will not start until the unit gets hot Once the fan turns on it will run until the unit cools 2 Plug the unit into a properly grounded electrical receptacle of the correct voltage size and p...

Page 8: ...Control screen appears showing a bar graph and a percentage of power setting 2 Push and hold the Control Knob for approximately 6 8 seconds A password screen will appear To enter the 3 digit password...

Page 9: ...contact the Hatco Service Department at 800 558 0607 or 414 671 6350 CAUTION Use only wipes pads and cleaners designed specifically for cleaning ceramic glass surfaces Wipe up all spills and splashes...

Page 10: ...e Pan Specifications in the OPERATION section of this manual Troubleshooting Questions If you continue to have problems resolving an issue please contact the nearest Authorized Hatco Service Agency or...

Page 11: ...sapplication improper installation or application of improper voltage 2 LIMITATION OF REMEDIES AND DAMAGES Hatco s liability and Buyer s exclusive remedy hereunder will be limited solely at Hatco s op...

Page 12: ...la suppression du r cipient la production de chaleur cesse instantan ment Les cuisini res induction d Hatco sont le r sultat de recherches approfondies et d essais sur le terrain Les mat riaux utilis...

Page 13: ...R DE D CHARGE LECTRIQUE Branchez l appareil une prise de courant mise la terre et pr sentant la tension la taille et la configuration ad quates Si la fiche et la prise ne se correspondent pas adressez...

Page 14: ...r la surchauffe des circuits lectroniques de l appareil Des sondes de temp rature surveillent les circuits lectroniques et envoient un signal l appareil lorsque ce dernier doit s teindre dans le cas o...

Page 15: ...application AVERTISSEMENT DANGER DE D CHARGE LECTRIQUE Branchez l appareil une prise de courant mise la terre et pr sentant la tension la taille et la configuration ad quates Si la fiche et la prise...

Page 16: ...s sur les c t s et en dessous de l appareil Placez l appareil sur un plan de travail dont la hauteur est appropri e un emplacement pratique utiliser L emplacement doit tre horizontal pour viter que l...

Page 17: ...an de commande et l appareil ne fonctionnera pas Mise en service 1 Chaque jour avant d allumer l appareil nettoyez la plaque de cuisson en vitroc ramique l aide d une lingette nettoyante d un papier a...

Page 18: ...chant DONE Termin puis 0 00 00 Le r glage de la puissance se met sur 0 Mise jour du micrologiciel Respectez la proc dure suivante pour t l charger les mises jour du micrologiciel de la plaque inductio...

Page 19: ...de Hatco au 800 558 0607 ou 414 671 6350 ATTENTION Utilisez uniquement des chiffons lingettes et produits nettoyants con us sp cifiquement pour nettoyer des surfaces en vitroc ramique essuyez les d ve...

Page 20: ...uvent provoquer des d charges lectriques et des br lures AVERTISSEMENT DANGER DE D CHARGE LECTRIQUE Mettez hors tension l appareil d branchez le cordon d alimentation et laissez l appareil refroidir a...

Page 21: ...TOUTES AUTRES ATTEINTES AUX DROITS DE LA PROPRI T INTELLECTUELLE Sans restreindre la port e g n rale des nonc s pr c dents CES GARANTIES NE COUVRENT PAS LES L MENTS SUIVANTS ampoules d clairage incand...

Page 22: ...Formulaire n IRNGHM 0117 22 Fran ais NOTAS...

Page 23: ...English Form No IRNGHM 0117 23 NOTES...

Page 24: ...arts Service St Louis 314 535 2222 NEBRASKA Anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEY Jay Hi...

Reviews: