background image

mAChO NAChO

®

Chip Warmers

Chauffe Frites

FDWD-1-mN and FST-1-mN Series/Série

Installation and Operating manual

manuel d'installation et d'utilisation

P/N 07.04.287.00

© 2015 Hatco Corporation

Register Online!

(see page 2)

S'inscrire en ligne!

(voir page 12)

hatcocorp.com

Do not operate this equipment unless you

have read and understood the contents of

this  manual!  Failure  to  follow  the

instructions contained in this manual may

result  in  serious  injury  or  death.  This

manual  contains  important  safety

information concerning the maintenance,

use,  and  operation  of  this  product.  If

you’re unable to understand the contents

of  this  manual,  please  bring  it  to  the

attention  of  your  supervisor.  Keep  this

manual  in  a  safe  location  for  future

reference.

English = p 2

No opere este equipo al menos que haya

leído y comprendido el contenido de este

manual! Cualquier falla en el seguimiento

de las instrucciones contenidas en este

manual puede resultar en un serio lesión

o  muerte.  Este  manual  contiene

importante información sobre seguridad

concerniente  al  mantenimiento,  uso  y

operación de este producto. Si usted no

puede  entender  el  contenido  de  este

manual  por  favor  pregunte  a  su

supervisor.  Almacenar  este  manual  en

una localización segura para la referencia

futura.

Ne pas utiliser cet équipement sans avoir

lu et compris le contenu de ce manuel !

Le  non-respect  des  instructions

contenues dans ce manuel peut entraîner

de  graves  blessures  ou  la  mort.  Ce

manuel  contient  des  informations

importantes  concernant  l'entretien,

l'utilisation  et  le  fonctionnement  de  ce

produit.  Si  vous  ne  comprenez  pas  le

contenu de ce manuel, veuillez le signaler

à votre supérieur. Conservez ce manuel

dans un endroit sûr pour pouvoir vous y

référer plus tard.

Français = p 12

WARNING

ADVERTENCIA

AVERTISSEMENT

Summary of Contents for MACHO NACHO FDWD-1-MN Series

Page 1: ...haya leído y comprendido el contenido de este manual Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesión o muerte Este manual contiene importante información sobre seguridad concerniente al mantenimiento uso y operación de este producto Si usted no puede entender el contenido de este manual por favor pregunte a su supervisor Almacenar ...

Page 2: ...portant Safety Information 3 model Description 4 model Designation 4 Specifications 5 Plug Configurations 5 Electrical Rating Chart 5 Dimensions 6 Installation 7 General 7 Operation 8 General 8 maintenance 9 General 9 Daily Cleaning 9 Removing the Glass Side Panels 9 Replacing a Display Light Bulbs 9 Troubleshooting Guide 10 Options and Accessories 11 Limited Warranty 11 Authorized Parts Distribut...

Page 3: ...ry operation CAUTION NOTICE WARNING ELECTRIC ShOCK hAzARD Plug unit into a properly grounded electrical receptacle of the correct voltage size and plug configuration If plug and receptacle do not match contact a qualified electrician to determine and install proper voltage and size electrical receptacle Turn OFF power switch unplug power cord and allow unit to cool before performing any cleaning a...

Page 4: ... power cord with plug Only minimal maintenance is required FDWD 1 mN model The FDWD 1 mN model is built of stainless steel with tempered glass sides and doors The unit holds up to 25 lbs 11 kg of chips The glass side panels and floor panels are removable for easy cleaning FDWD 1 mN POWER ON OFF I O Switch Temperature Control Upper Door Lower Door FST 1 mN model The FST 1 mN model is built of stain...

Page 5: ...lectrical cord and plug installed Plugs are supplied according to the applications ELECTRIC ShOCK hAzARD Plug unit into a properly grounded electrical receptacle of the correct voltage size and plug configuration If plug and receptacle do not match contact a qualified electrician to determine and install proper voltage and size electrical receptacle NOTE Specification label is located on the opera...

Page 6: ... 483 mm 18 11 16 475 mm model Cabinet Opening Width Upper Door Opening height Lower Door Opening height FDWD 1 mN 16 3 8 416 mm 9 1 8 233 mm 9 1 16 230 mm FST 1 mN 18 5 8 474 mm 11 3 16 285 mm 9 7 8 251 mm SPECIFICATIONS 6 Form No mNm 0615 English A D E C B Front View Side View add 3 76 mm to the height of the unit if the 4 leg option is installed Dimensions Door Opening Dimensions Dimensions ...

Page 7: ...y and strong enough to support the weight of the unit and contents Transport unit in upright position only Before moving or tipping unit secure all glass surfaces doors pan rails and or skirts with tape Failure to do so may result in damage 1 Remove the unit from the carton Two people are required for this step 2 Remove the information packet NOTE To prevent delay in obtaining warranty coverage co...

Page 8: ...trol to the desired temperature setting 4 allow 20 minutes to heat the cabinet to operating temperature 5 Open the upper door and fill the unit with chips BURN hAzARD Some exterior surfaces on the unit will get hot Use caution when touching these areas Shutdown 1 move the Power ON OFF I O switch to the OFF O position 2 allow the unit to cool and perform the Cleaning procedure in the maINTENaNCE se...

Page 9: ... panels are removable for ease of cleaning The cabinet floor is accessible for cleaning when the floor panels are removed NOTICE WARNING 5 Clean the glass side panels and door panels using ordinary glass cleaner and a damp soft cloth or paper towel FDWD 1 mN models The side panels are removable for detailed cleaning if necessary Refer to the Removing the Glass Side Panels procedure in this section...

Page 10: ...gh limit is tripped or open Contact authorized Service agent or Hatco for assistance Incorrect voltage supplied to heating element Contact authorized Service agent or Hatco for assistance Blower motor is not working Check blower motor refer to Symptom Unit operates but is not circulating air inside cabinet air heating element is defective Contact authorized Service agent or Hatco for assistance TR...

Page 11: ...e tampering or misapplication improper installation or application of improper voltage 2 LImITATION OF REmEDIES AND DAmAGES Hatco s liability and Buyer s exclusive remedy hereunder will be limited solely at Hatco s option to repair or replacement using new or refurbished parts or Product by Hatco or a Hatco authorized service agency other than where Buyer is located outside of the United States Ca...

Page 12: ...ur le Propriétaire 12 Introduction 12 Consignes de Sécurité Importantes 13 Description du modèle 14 Désignation du modèle 14 Caractéristiques Techniques 15 Configuration des fiches 15 Tableau des valeurs nominales électriques 15 Dimensions 16 Installation 17 Généralités 17 mode d emploi 18 Généralités 18 maintenance 18 Généralités 18 Nettoyage quotidien 19 Retrait des panneaux en verre latéraux 19...

Page 13: ...nnement pour éviter les dysfonctionnements et assurer un fonctionnement sain AVERTISSEMENT ATTENTION AVIS DANGER DE DéChARGE éLECTRIQUE Brancher l appareil sur une prise de courant avec terre de tension de format et de configuration des broches corrects Si la fiche et la prise ne se correspondent pas s adresser à un électricien qualifié pour déterminer et installer une prise de courant de format e...

Page 14: ...sont livrés avec un cordon d alimentation et une prise de 1829 mm 6 L appareil nécessite un entretien minimum FDWD 1 mN modèle Le modèle FDWD 1 mN est fabriqué en acier inoxydable les parties latérales et les portes sont en verre trempé L appareil peut contenir jusqu à 11 kg 25 lb de frites Les panneaux en verre latéraux et les panneaux inférieurs sont amovibles pour un nettoyage facile FDWD 1 mN ...

Page 15: ...nies sont compatibles avec les applications prévues DANGER DE DéChARGE éLECTRIQUE Brancher l appareil sur une prise de courant avec terre de tension de format et de configuration des broches corrects Si la fiche et la prise ne se correspondent pas s adresser à un électricien qualifié pour déterminer et installer une prise de courant de format et de tension corrects NOTA L étiquette des caractérist...

Page 16: ...geur de l espace de l armoire hauteur de l espace de la porte supérieure hauteur de l espace de la porte inférieure FDWD 1 mN 416 mm 16 3 8 233 mm 9 1 8 230 mm 9 1 16 FST 1 mN 474 mm 18 5 8 285 mm 11 3 16 251 mm 9 7 8 16 Formulaire n mNm 0615 CARACTéRISTIQUES TEChNIQUES Français A D E C B Vue de face Vue de côté ajoutez 76 mm 3 à la hauteur de l appareil si ce dernier possède un pied de 102 mm 4 D...

Page 17: ...empérature ambiante de 21 C 70 F minimum DANGER D INCENDIE Placer l appareil à un minimum de 25 mm des parois et matières combustibles Si une dis tance sûre n est pas maintenue la chaleur peut provoquer une combustion ou une altération de couleur Placer l appareil sur un plan de travail de hauteur correcte à un endroit qui convient pour son utilisation Le support doit être de niveau pour éviter to...

Page 18: ...e AVERTISSEMENT ATTENTION Commandes du modèle FDWD 1 mN Commandes du modèle FST 1 mN Interrupteur d ALIMENTATION MARCHE ARRÊT I O Commande de la TEMPÉRATURE Interrupteur d ALIMENTATION MARCHE ARRÊT I O CABINET TEMP Monitor Commande de la TEMPÉRATURE mAINTENANCE Généralités Les chauffe frites macho Nacho de Hatco sont conçus pour une durabilité et des performances maximum avec un entretien minimum ...

Page 19: ... les ergots de verrouillage en tournant légèrement et veillez à ce qu ils s emboîtent dans la structure du panneau de porte Sur les modèles FST 1 mN alignez les quatre trous de la structure du panneau de porte avec les quatre ergots de montage de l unité et placez la structure du panneau de porte AVIS Retrait des panneaux en verre latéraux FDWD 1 mN Suivez les instructions suivantes uniquement pou...

Page 20: ...hée ou ouverte Contactez votre agent de maintenance agréé ou Hatco pour assistance Tension incorrecte fournie à l élément de chauffage Contactez votre agent de maintenance agréé ou Hatco pour assistance Le moteur du ventilateur ne fonctionne pas Vérifiez le moteur du ventilateur voir le cas L appareil fonctionne mais l air ne circule pas dans l armoire L les élément s de chauffage à air est sont d...

Page 21: ... l appareil en position debout Si l appareil n est pas plan ou s il balance tournez l embout réglable du pied approprié pour aplanir l appareil Rallonger Réduire Embout réglable Ampoules halogènes de la vitrine Des ampoules halogènes antichocs de vitrine peuvent être commandées pour remplacer les ampoules à incandescence classiques Les ampoules sont recouvertes d un enduit spécial pour pallier tou...

Page 22: ...PROPRIÉTÉ INTELLECTUELLE Sans restreindre la portée générale des énoncés précédents CES GaRaNTIES NE COUVRENT PaS ampoules d éclairage à incandescence enduites lumières fluorescentes ampoules de lampes chauffantes ampoules d éclairage à halogène enduites ampoules de lampes chauffantes au xénon tubes d éclairage DEL composants en verre et fusibles défaut de produit dans la cuve d un appareil de cha...

Page 23: ...NOTES Form No mNm 0615 23 English ...

Page 24: ... 890 0700 Kaemmerlen Parts Service St Louis 314 535 2222 NEBRASKA anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEy Jay Hill Repair Fairfield 973 575 9145 Service Plus Flanders 973 691 6300 NEW yORK acme american Repairs Inc Brooklyn 718 456 6544 alpro Service Co Brooklyn 718 386 2515 appliance Inst...

Reviews: