INSTALLATION
Form No. HBGM-0608
7
Countertop Cutout
Model
Minimum Width
Maximum Width
Minimum Depth
Maximum Depth
HBGB-2418
24-3/4″ (629 mm)
25″ (635 mm)
18-3/4″ (476 mm)
19″ (483 mm)
HBGB-3018
30-3/4″ (781 mm)
31″ (787 mm)
18-3/4″ (476 mm)
19″ (483 mm)
HBGB-3618
36-3/4″ (933 mm)
37″ (940 mm)
18-3/4″ (476 mm)
19″ (483 mm)
HBGB-4818
48-3/4″ (1238 mm)
49″ (1245 mm)
18-3/4″ (476 mm)
19″ (483 mm)
HBGB-6018
60-3/4″ (1543 mm)
61″ (1549 mm)
18-3/4″ (476 mm)
19″ (483 mm)
HBGB-7218
72-3/4″ (1848 mm)
73″ (1854 mm)
18-3/4″ (476 mm)
19″ (483 mm)
Trim Mounting Ring
Countertop
Apply a bead of NSF-approved
sealant between the countertop
material and trim mounting ring.
Sealant must be rated for use at
a minimum temperature of
250°F (121°C).
Figure 7. HBGB Countertop Installation