GLO-RAY

®

Heated Glass Overshelves

GR3 & GR3L Series

Installation &

Operating Manual

I&W #07.05.175.00

This manual contains important safety information
concerning the maintenance, use and operation of this
product. Failure to follow the instructions contained in this
manual may result in serious injury. If you’re unable to
understand the contents of this manual, please bring it to
the attention of your supervisor. Do not operate this
equipment unless you have read and understood the
contents of this manual.

Este manual contiene importante información sobre
seguridad concerniente al mantenimiento, uso y
operación de este producto. Cualquier falla en el
seguimiento de las instrucciones contenidas en este
manual puede resultar en un serio daño. Si usted no
puede entender el contenido de este manual por
favor pregunte a su supervisor. No opere este
equipo al menos que haya leído y comprendido el
contenido de este manual.

Summary of Contents for GR3-27

Page 1: ...lease bring it to the attention of your supervisor Do not operate this equipment unless you have read and understood the contents of this manual Este manual contiene importante información sobre seguridad concerniente al mantenimiento uso y operación de este producto Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio daño Si usted no puede e...

Page 2: ...mum durability attractive appearance and optimum performance Every unit is thoroughly inspected and tested prior to shipment Important Owner Information i Introduction i Important Safety Information 1 Model Description 3 All Models 3 GR3 Models 3 GR3L Models 3 Model Designation 3 Specifications 4 Electrical Requirements 4 Electrical Rating Charts 4 Dimensions 4 Installation 5 Unpacking 5 Location ...

Page 3: ...her applicable codes Connections should be made by a qualified licensed electrician WARNINGS To avoid any injury turn the power switch OFF and allow to cool completely before performing any cleaning or maintenance To avoid any injury do not allow liquids to spill onto the Heated Glass Overshelf Some exterior surfaces on the unit will get hot Use caution when touching these areas to avoid injury To...

Page 4: ...s and abrasive materials may scratch the glass shelf marring its appearance and making it susceptible to dirt accumulation It is recommended that glass overshelves be used for food products contained in disposable paper or plastic containers or wrapping IMPORTANT Read the following important safety information to avoid personal injury or death and to avoid damage to the equipment or property Damag...

Page 5: ...es a 3 914 mm flexible electrical conduit GR3 MODELS The GR3 Heated Glass Overshelf is constructed of stainless steel or powdercoat painted steel in Designer colors and glass Featuring a remote mounted On Off toggle switch Ground Fault Circuit Interrupt GFCI safety indicator light and one adjustable infinite heat control for the heated glass overshelf Figure 1 Glo Ray Model GR3 35 with Optional Br...

Page 6: ...uit 73 lbs 33 kg GR3L 41 120 1179 9 8 Conduit 85 lbs 38 kg GR3HL 41 120 1931 16 1 Conduit 85 lbs 38 kg ELECTRICAL RATING CHART GR3L MODELS DIMENSIONS Width Depth Height Interior Interior Interior Model A B C D E F GR3 29 29 27 3 16 13 1 2 25 11 16 10 3 16 9 GR3H 29 737 mm 691 mm 343 mm 652 mm 259 mm 229 mm GR3 35 35 27 3 16 13 1 2 31 11 16 10 3 16 9 GR3H 35 889 mm 691 mm 343 mm 805 mm 259 mm 229 m...

Page 7: ... where the ambient air temperature is constant and is a minimum of 70 F 21 C WARNING For safe and proper operation the unit must be located a reasonable distance from combustible walls and materials If safe distances are not maintained discoloration or combustion could occur CAUTION To avoid any injury or damage locate the unit at the proper counter height in an area that is convenient for use The...

Page 8: ... and Figure 4 Mounting the Unit Mounting Bracket Screw Not Supplied Nut Not Supplied Front Edge Of Unit Center Line Of Unit Left Edge Of Unit Flexible Conduit Counter Mount Cover secure with bolts and nuts Units mounted to a metal surface may require a backing plate installed to the underside of the surface in order to increase unit stability backing plate not supplied 8 Secure counter mount cover...

Page 9: ...l box should be installed by a qualified electrician NOTE When mounting the remote mounted control box insure space is available to access the GFCI reset button NOTICE The Remote Mounted Control Box must be installed outside of the heat zone Locating the control box inside the heat zone will cause the switches to overheat malfunction and fail See Figure 6 for minimum mounting distances ...

Page 10: ...eep packaged food on the glass shelf warm The top side of the Heated Glass Overshelf with the infinite heat control switch set on high reaches 180 F 82 C Allow 30 minutes for unit to reach operating temperature NOTE To operate the unit for display only with no heat GR3L Series only position the heat control to the lowest or OFF setting NOTICE Do not allow the glass shelf to overheat Overheating ma...

Page 11: ... switch off and wait until the unit has cooled Remove the protective lens cover from the fixture and carefully twist the fluorescent tube and pull to remove it from the sockets Reverse procedure to re assemble WARNING After installing a fluorescent light bulb make sure to reinstall the protective lens cover Breakage of a bulb not properly covered could result in personal injury and or food contami...

Page 12: ... protective paper from acrylic surfaces 2 Loosen 3 screws from underside of shelf Slide mounting bracket into position with studs facing to the front and down Tighten 3 screws Figure 8 Installing Accessory Breath Protectors 3 Align breath protector mounting holes with studs and secure using acorn nuts provided Do not overtighten Stud Breath Protector Mounting Bracket Acorn Nut ...

Page 13: ...THER WARRANTY EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR PATENT OR OTHER INTELLECTUAL PROPERTY RIGHT INFRINGEMENT Without limiting the generality of the foregoing SUCH WARRANTIES DO NOT COVER Coated incandescent light bulbs fluorescent lights lamp warmer heat bulbs glass components Product failure in booster tank...

Page 14: ...Form No GR3M 0807 12 NOTES ...

Page 15: ...Form No GR3M 0807 13 NOTES ...

Page 16: ...aemmerlen Parts Service St Louis 314 535 2222 NEBRASKA Anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEY Jay Hill Repair Fairfield 973 575 9145 Service Plus Flanders 973 691 6300 NEW YORK Acme American Repairs Inc Brooklyn 718 456 6544 Alpro Service Co Brooklyn 718 386 2515 Appliance Installation Bu...