INSTALLATION

WARNING

For safe and proper operation, the unit must be
located a reasonable distance from combustible
walls and materials. If safe distances are not
maintained, discoloration or combustion could
occur.

CAUTION

To avoid any injury or damage locate the unit at
the proper counter height, in an area that is
convenient for use. The location should be level
to prevent the shelf or its contents from
accidentally falling, and strong enough to
support the weight of the unit and food.

CAUTION

The National Sanitation Foundation (NSF)
requires that GRS Series units over 36" 
(914 mm) in length or weighing more than 80 lbs.
(36 kg) to be either sealed or raised on the
installation surface. If this unit cannot be sealed
at the point of use, 4" (102 mm) legs are included
to allow for proper cleaning access below unit.
See ACCESSORIES 
for installation instructions.

WARNING

To avoid any injury or damage to the unit do not
pull unit by power cord.

WARNING

To prevent any injury, discontinue use if power
cord is frayed or worn.

GRS MODELS

1. Remove the unit from the carton and lay it upside

down on the cardboard.

2. Install the four feet into the corner holes on the

base. Tighten securely but do not overtighten. 

NOTE: If 4" (102 mm) legs are required, see

ACCESSORIES

in this manual for installation

instructions.

3. Place one rubber boot over each metal foot. 

(For 1" (25 mm) only.)

4. Turn unit upright and position warmer in desired

location.

Remove and save

these screws

Figure 4. Models GRSB & GRSBF Underside

GRSB & GRSBF MODELS

1. Remove the unit from the carton and place it

upside down on the cardboard.

2. Remove and save the four screws (8-32) from

the underside of the unit. See Figure 4.  

NOTE: The control box may be moved to the most
convenient location on the underside of the unit. For
semi-remote installations, we recommend you leave
the control in place until the unit is placed into the
countertop. See Figure 7.

CAUTION

Damage to non-metallic countertop material
caused by heat generated from Hatco
equipment is not covered under the Hatco
warranty. Recommended for use in metallic
counters. For other surfaces, verify that the
material is suitable for temperature up to 180°F
(82°C).

3. Prepare countertop opening. (See Figures 5 & 6

for recommended countertop cutout
dimensions.)

4. Apply a bead of NSF (National Sanitation

Foundation) approved sealant between the
countertop material and mounting flange.

5. Place the unit into the countertop opening.

Summary of Contents for GLO-RAY GRS Series

Page 1: ...se bring it to the attention of your supervisor Do not operate this equipment unless you have read and understood the contents of this manual Este manual contiene importante información sobre seguridad concerniente al mantenimiento uso y operación de este producto Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio daño Si usted no puede ente...

Page 2: ...pected and tested prior to shipment Important Owner Information i Introduction i Important Safety Information 1 Specifications 2 Plug Configurations 2 Dimensions GRS Models 2 Dimensions GRSB Models 3 Dimensions GRSBF Models 4 Electrical Rating Chart GRS Models 5 Electrical Rating Chart GRSB Models 6 Electrical Rating Chart GRSBF Models 8 Model Descriptions 10 GRS Model 10 GRSB GRSBF Models 10 Inst...

Page 3: ...istics that will allow them to operate safely in Hatco equipment It is essential to use Hatco Replacement Parts when repairing Hatco equipment Failure to use Hatco Replacement Parts may subject operators of the equipment to hazardous electrical voltage resulting in electrical shock or burn CAUTIONS Unit is not weatherproof For safe and proper operation locate the unit indoors where the ambient air...

Page 4: ...mm 2 1 4 57 mm GRS 24 I 24 610 mm 19 1 2 495 mm 2 1 4 57 mm GRS 30 I 30 762 mm 19 1 2 495 mm 2 1 4 57 mm GRS 36 I 36 914 mm 19 1 2 495 mm 2 1 4 57 mm GRS 42 I 42 1067 mm 19 1 2 495 mm 5 1 4 133 mm GRS 48 I 48 1219 mm 19 1 2 495 mm 5 1 4 133 mm GRS 54 I 54 1372 mm 19 1 2 495 mm 5 1 4 133 mm GRS 60 I 60 1524 mm 19 1 2 495 mm 5 1 4 133 mm GRS 66 I 66 1676 mm 19 1 2 495 mm 5 1 4 133 mm GRS 72 I 72 182...

Page 5: ...42 1067 mm 7 1 16 179 mm 19 1 2 495 mm 21 533 mm 2 7 8 73 mm 2 1 32 52 mm GRSB 42 O 43 1 2 1105 mm 42 1067 mm 7 1 16 179 mm 30 762 mm 31 1 2 800 mm 2 7 8 73 mm 2 1 32 52 mm GRSB 48 F 49 1 2 1257 mm 48 1219 mm 7 1 16 179 mm 15 1 2 394 mm 17 432 mm 2 7 8 73 mm 2 1 32 52 mm GRSB 48 I 49 1 2 1257 mm 48 1219 mm 7 1 16 179 mm 19 1 2 495 mm 21 533 mm 2 7 8 73 mm 2 1 32 52 mm GRSB 48 O 49 1 2 1257 mm 48 1...

Page 6: ...m 2 1 32 52 mm GRSBF 42 I 43 1 2 1105 mm 42 3 32 1069 mm 7 1 16 179 mm 19 1 2 495 mm 21 533 mm 2 1 4 57 mm 2 1 32 52 mm GRSBF 42 S 43 1 2 1105 mm 42 3 32 1069 mm 7 1 16 179 mm 24 610 mm 25 1 2 648 mm 2 1 4 57 mm 2 1 32 52 mm GRSBF 42 O 43 1 2 1105 mm 42 3 32 1069 mm 7 1 16 179 mm 30 762 mm 31 1 2 800 mm 2 1 4 57 mm 2 1 32 52 mm GRSBF 48 F 49 1 2 1257 mm 48 3 32 1222 mm 7 1 16 179 mm 15 1 2 394 mm ...

Page 7: ... 0 NEMA 5 15P 32 lbs 15 kg 120 600 5 0 NEMA 5 15P 32 lbs 15 kg 220 548 2 5 CEE 7 7 Schuko 32 lbs 15 kg 240 652 2 7 BS 1363 32 lbs 15 kg 220 230 CE 548 600 2 5 2 6 CEE 7 7 Schuko 32 lbs 15 kg 230 240 CE 600 652 2 6 2 7 BS 1363 32 lbs 15 kg GRS 48 I 100 700 7 0 NEMA 5 15P 36 lbs 16 kg 120 700 5 8 NEMA 5 15P 36 lbs 16 kg 220 640 3 0 CEE 7 7 Schuko 36 lbs 16 kg 240 760 3 2 BS 1363 36 lbs 16 kg 220 230...

Page 8: ...5 15P 25 lbs 11 kg 220 665 3 0 CEE 7 7 Schuko 25 lbs 11 kg 240 665 2 8 BS 1363 25 lbs 11 kg 220 230 CE 665 727 3 0 3 2 CEE 7 7 Schuko 25 lbs 11 kg 230 240 CE 611 665 2 7 2 8 BS 1363 25 lbs 11 kg GRSB 30 O 120 950 7 9 NEMA 5 15P 28 lbs 13 kg 220 916 4 2 CEE 7 7 Schuko 28 lbs 13 kg 240 985 4 1 BS 1363 28 lbs 13 kg GRSB 36 F 120 590 4 9 NEMA 5 15P 26 lbs 12 kg 220 540 2 5 CEE 7 7 Schuko 26 lbs 12 kg ...

Page 9: ...3 CEE 7 7 Schuko 42 lbs 19 kg 230 240 CE 1019 1110 4 4 4 6 BS 1363 42 lbs 19 kg GRSB 60 F 120 950 7 9 NEMA 5 15P 45 lbs 20 kg 220 870 4 0 CEE 7 7 Schuko 45 lbs 20 kg 240 1034 4 3 BS 1363 45 lbs 20 kg GRSB 60 I 100 1220 12 2 NEMA 5 15P 50 lbs 23 kg 120 1220 10 2 NEMA 5 15P 50 lbs 23 kg 220 1220 5 5 CEE 7 7 Schuko 50 lbs 23 kg 240 1220 5 1 BS 1363 50 lbs 23 kg 220 230 CE 1220 1333 5 5 5 8 CEE 7 7 Sc...

Page 10: ...15P 28 lbs 13 kg GRSBF 36 F 120 590 4 9 NEMA 5 15P 25 lbs 11 kg GRSBF 36 I 100 780 7 8 NEMA 5 15p 26 lbs 12 kg 120 780 6 5 NEMA 5 15P 26 lbs 12 kg GRSBF 36 S 120 950 7 9 NEMA 5 15P 31 lbs 15 kg 220 870 4 0 CEE 7 7 Schuko 31 lbs 15 kg 240 1034 4 3 BS 1363 31 lbs 15 kg GRSBF 36 O 120 1110 9 3 NEMA 5 15P 32 lbs 15 kg 240 1110 4 6 NEMA 6 15P 32 lbs 15 kg 220 230 CE 1110 1213 5 0 5 3 CEE 7 7 Schuko 32 ...

Page 11: ...20 1220 10 2 NEMA 5 15P 50 lbs 23 kg GRSBF 60 S 120 1500 12 5 NEMA 5 20P 53 lbs 24 kg 220 1372 6 2 CEE 7 7 Schuko 53 lbs 24 kg 240 1634 6 8 BS 1363 53 lbs 24 kg GRSBF 60 O 120 1750 14 6 NEMA 5 20P 54 lbs 25 kg 240 1750 7 3 NEMA 6 15P 54 lbs 25 kg 220 230 CE 1750 1912 8 0 8 3 CEE 7 7 Schuko 54 lbs 25 kg 230 240 CE 1607 1750 7 0 7 3 BS 1363 54 lbs 25 kg GRSBF 72 F 120 1130 9 4 NEMA 5 15P 52 lbs 24 k...

Page 12: ...tat with a range of 80 to 200 F 27 to 93 C an illuminated on off switch and mounting brackets The attached control box can be located up to 3 914 mm from the unit A 6 1829 mm cord and plug is attached to the control box The Drop In Heated Shelf has a 3 4 19 mm flanged edge that allows the unit to drop into a countertop opening The shelf is easy to clean with a soft damp cloth or non abrasive clean...

Page 13: ...oard 2 Install the four feet into the corner holes on the base Tighten securely but do not overtighten NOTE If 4 102 mm legs are required see ACCESSORIES in this manual for installation instructions 3 Place one rubber boot over each metal foot For 1 25 mm only 4 Turn unit upright and position warmer in desired location Remove and save these screws Figure 4 Models GRSB GRSBF Underside GRSB GRSBF MO...

Page 14: ...0 1 4 514 mm GRSB 42 O 42 1 2 1080 mm 42 3 4 1086 mm 30 1 2 775 mm 30 3 4 781 mm GRSB 48 F 48 1 2 1232 mm 48 3 4 1238 mm 16 406 mm 16 1 4 413 mm GRSB 48 I 48 1 2 1232 mm 48 3 4 1238 mm 20 508 mm 20 1 4 514 mm GRSB 48 O 48 1 2 1232 mm 48 3 4 1238 mm 30 1 2 775 mm 30 3 4 781 mm GRSB 54 I 54 1 2 1384 mm 54 3 4 1391 mm 20 508 mm 20 1 4 514 mm GRSB 60 F 60 1 2 1537 mm 60 3 4 1543 mm 16 406 mm 16 1 4 41...

Page 15: ...2 3 4 1086 mm 20 508 mm 20 1 4 514 mm GRSBF 42 S 42 1 2 1080 mm 42 3 4 1086 mm 24 1 2 622 mm 24 3 4 629 mm GRSBF 42 O 42 1 2 1080 mm 42 3 4 1086 mm 30 1 2 775 mm 30 3 4 781 mm GRSBF 48 F 48 1 2 1232 mm 48 3 4 1238 mm 16 406 mm 16 1 4 413 mm GRSBF 48 I 48 1 2 1232 mm 48 3 4 1238 mm 20 508 mm 20 1 4 514 mm GRSBF 48 S 48 1 2 1232 mm 48 3 4 1238 mm 24 1 2 622 mm 24 3 4 629 mm GRSBF 48 O 48 1 2 1232 mm...

Page 16: ... the control box to a semi remote location remove it from the bottom of the unit If necessary remove the end brackets from the control box rotate and reposition them The control box will require a hole mounting pattern of 7 5 8 x 1 1 4 194 mm x 32 mm for 8 screws See Figure 7 for mounting distances 10 Once all components are secured the unit may be plugged in and turned on NOTE A 6 1829 mm cord is...

Page 17: ...0 F 21 C 1 Plug warmer into a properly grounded electrical outlet of the correct voltage size and plug configuration See SPECIFICATIONS for details 2 Place the Power Switch in the ON position See Figures 8 and 9 3 Turn the thermostat to the desired temperature settings 4 Allow unit 30 minutes to reach operating temperature Figure 8 Operating Controls GRS Power On Off Switch Shelf Thermostat Figure...

Page 18: ...erve the finish of the Glo Ray Heated Shelf it is recommended that the surfaces be wiped daily with a damp cloth Stubborn stains may be removed with a good stainless steel cleaner or a non abrasive cleaner Hard to reach areas should be cleaned with a small brush and mild soap CAUTION Use only non abrasive cleaners Abrasive cleaners could scratch the finish of your Glo Ray Heated Shelf marring its ...

Page 19: ... OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR PATENT OR OTHER INTELLECTUAL PROPERTY RIGHT INFRINGEMENT Without limiting the generality of the foregoing SUCH WARRANTIES DO NOT COVER Coated incandescent light bulbs fluorescent lights lamp warmer heat bulbs glass components Product failure in booster tank fin tube heat exchange...

Page 20: ...ices St Louis 314 890 0700 Kaemmerlen Parts Service St Louis 314 535 2222 NEBRASKA Anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEY Jay Hill Repair Fairfield 973 575 9145 Service Plus Flanders 973 691 6300 NEW YORK Acme American Repairs Inc Brooklyn 718 456 6544 Alpro Service Co Brooklyn 718 386 25...

Reviews: