Form No. GRSM-0705
14
INSTALLATION
6. Assemble the Z-brackets to the underside of the
unit using the four screws removed in step 2.
NOTE: Units 48" (1219 mm) or longer require two
additional Z-brackets installed midway along the
front and rear of the unit.
7. Adjust the 1/4-20 screws on the Z-brackets until
the top flange lies flat on the countertop.
8. Remove any excess sealant.
CAUTION
Use of excessive force when tightening
mounting screws may damage unit or
countertop (GRSB and GRSBF units).
9. If you wish to move the control box to a semi-
remote location, remove it from the bottom of the
unit. If necessary, remove the end brackets from
the control box, rotate and reposition them. The
control box will require a hole mounting pattern of
7-5/8" x 1-1/4" (194 mm x 32 mm) for #8 screws.
See Figure 7 for mounting distances.
10.Once all components are secured, the unit may
be plugged in and turned on.
NOTE: A 6' (1829 mm) cord is supplied with this
appliance; any excess cord should be neatly routed
so it does not hang down.
Panel
Recessed
Surface
TOP VIEW
Use this arc to determine
approximate mounting
distances for semi-remote
controls
Under counter
Optional
Standard
Optional
Figure 7. Maximum Remote Mounting Distance for Control Box