Form No. FSHACM-0719
English
INSTALLATION
Drain Outlet
Water
Supply
Inlet
Plumbing Connections
Plumbing (Humidified Models Only)
Auto-Fill Installation
NOTE: Water supply inlet and drain connections must be made
with flexible hose. If required, a ball valve or gate valve,
line strainer, union(s) and vacuum breaker or other anti-
siphon device must be supplied by plumber or installer.
NOTE: Water filter must be used and maintained. Product
failure caused by liming or sediment buildup is not
covered under warranty.
Materials required for installation include plumbing tape or pipe
sealant, and appropriate fittings for application.
NOTICE
Product failure caused by liming or sediment buildup is
not covered under warranty.
1. Turn off water supply.
2. Insert 1/4" OD water supply tubing fully into water inlet by
pushing in fitting on unit.
NOTE: Install filter cartridge with flow arrow towards the
equipment.
3. Insert other end of 1/4" water supply tubing fully into filter
cartridge by pushing in fitting on unit. (Filter supplied by
Hatco, P/N 03.05.079.00.) Use minimum length tubing
from filter to unit.
4. Connect other end of filter cartridge assembly to 1/4" water
supply inlet with a shut-off valve. Filter connection fits 1/4"
OD nylon tubing. Use adapter fittings to connect to copper
tube or pipe connection.
• Pressure Range: 20–125 psi (138–862 kPa)
• Temperature Range: 35°–100°F (2°–38°C)
5. Tighten connections securely.
6. Turn water supply on. Check for leaks before leaving
installation.
NOTE: Flush new filter cartridge with water for five minutes
before use.
See MAINTENANCE section for Filter Cartridge Replacement.
A drain connection is located inside the cabinet cavity for
manually draining the water reservoir. A male hose connector
is included. See MAINTENANCE for draining information.