background image

Form No. FSHACM-0719

11

English

MAINTENANCE

Draining the Water Reservoir

The water reservoir in humidified units must be drained prior to 

moving the cabinet as well as during the “Removing Lime and 

Mineral Deposits” procedure.

WARNING

ELECTRIC SHOCK HAZARD: Turn OFF power switch, 

unplug power cord, and allow unit to cool before 

performing any cleaning, adjustments, or maintenance.

  1.  Turn off the unit, unplug the power cord, and allow the unit 

to cool.

NOTE: A cooling fan inside the unit will run for a short time after 

the unit is turned off.

  2.  Locate the valve inside the cabinet on the underside of the 

ceiling sheet. 

CAUTION: BURN HAZARD—Ceiling sheet 

and water in reservoir are hot during operation. Allow 

to cool before draining.

CAUTION

BURN HAZARD: Ceiling sheet and water in reservoir are 

hot during operation. Allow to cool before draining.

  3.  Position a one gallon (four liter) container under the water 

outlet to hold the draining water. 

  4.  Turn the valve handle from the horizontal position (closed) 

to the vertical postion (open) to drain the reservoir.

  5.  Once the reservoir is empty, close the valve.

NOTE: If the water used has an excessive amount of lime or 

mineral  content,  follow  the 

REMOVING LIME AND 

MINERAL DEPOSITS 

procedure for periodic cleaning 

and deliming of the water reservoir.

NOTE: Unit failure caused by liming or sediment buildup is not 

covered under warranty.

Removing Lime and Mineral Deposits

Use the following procedure for periodic cleaning and de-liming 

of the water reservoir in humidified units.

NOTE: The  lime  and  mineral  content  of  the  water  used  for 

daily operation will determine how often the deliming 

procedure must be performed.

NOTE: Perform this procedure when the unit will not be used 

for a period of time, such as the end of the day.

 1.  Turn off the unit, unplug the power cord, and allow the unit 

to cool.

NOTE: A cooling fan inside the unit will run for a short time 

after the unit is turned off.

 2.  After the unit has cooled down, perform the “Draining the 

Water Reservoir” procedure in this section.

 3. Fill the water reservoir with a mixture of 75% water and 

25% white vinegar. Do not use flavored vinegar.

 4.  Plug in and turn on the unit.
 5.  Set both the air temperature and humidity to their highest 

settings and allow the unit to run for 60 minutes.

 6.  Turn off the unit, unplug the power cord, and allow the unit 

to cool.

NOTE: A cooling fan inside the unit will run for a short time 

after the unit is turned off.

 7.  Perform the “Draining the Water Reservoir” procedure to 

empty the deliming solution from the water reservoir.

 8. Continue to fill and drain the water reservoir with clean 

water until the deliming solution is rinsed through and the 

water discharge is clean.

 9. Plug the unit into its power source and fill the reservoir 

as usual for daily operation using the procedure in the 

OPERATION section of this manual.

Summary of Contents for FLAV-R-SAVOR FSHAC-2

Page 1: ...en un serio lesi n o muerte Este manual contiene importante informaci n sobre seguridad concerniente al mantenimiento uso y operaci n de este producto Si usted no puede entender el contenido de este m...

Page 2: ...ation of a unit Important Owner Information 2 Introduction 2 Important Safety Information 3 Model Description 4 Model Designation 4 Specifications 5 Plug Configurations 5 Electrical Rating Chart 5 Dim...

Page 3: ...atch contact a qualified electrician to determine and install proper voltage and size electrical receptacle Turn OFF power switch unplug power cord and allow unit to cool before performing any cleanin...

Page 4: ...d units are available in auto fill or manual fill versions both having the capacity to hold 2 1 4 gallons 9 liters The FSHACH 2 two pan model comes equipped with four rubber feet The FSHACH 3 three pa...

Page 5: ...IFICATIONS Electrical Rating Chart Plug Configurations Units are supplied from the factory with an electrical cord and plug installed plugs are supplied according to the applications WARNING ELECTRIC...

Page 6: ...511 mm 18 3 4 478 mm 24 3 8 619 mm 26 1 2 673 mm 6 152 mm 18 1 4 464 mm 18 3 4 478 mm FSHAC 2PT 24 610 mm 29 737 mm 34 864 mm 18 456 mm 4 1 2 114 mm 22 1 8 562 mm 26 1 8 664 mm FSHACH 2PT 24 610 mm 29...

Page 7: ...size and plug configuration If plug and receptacle do not match contact a qualified electrician to determine and install proper voltage and size electrical receptacle Unit is not weatherproof Locate u...

Page 8: ...o water inlet by pushing in fitting on unit NOTE Install filter cartridge with flow arrow towards the equipment 3 Insert other end of 1 4 water supply tubing fully into filter cartridge by pushing in...

Page 9: ...Shutdown 1 Move the Power I O on off switch to the O off position and allow the unit to cool NOTE A cooling fan inside the unit will run for a short time after the unit is turned off 2 Perform the Dai...

Page 10: ...when any of the following occur Noticeable drop in water flow Unpleasant tastes and or odors return Cartridge capacity is reached Every six months Follow these instructions when replacement is necessa...

Page 11: ...ng or sediment buildup is not covered under warranty Removing Lime and Mineral Deposits Use the following procedure for periodic cleaning and de liming of the water reservoir in humidified units NOTE...

Page 12: ...ervice Agent or Hatco for assistance Unit is heating but is producing too much humidity inside the cabinet causing steam inside unit Humidity control is set too high Adjust the humidity control to a l...

Page 13: ...Back to Back Mounting Kit Pans Accessory aluminum sheet pans are available directly from Hatco Order Hatco stock item 18 Sheet Pan Full size sheet pan 18 x 26 457 mm x 660 mm Full Size Sheet Pan Alum...

Page 14: ...PARTICULAR PURPOSE OR PATENT OR OTHER INTELLECTUAL PROPERTY RIGHT INFRINGEMENT Without limiting the generality of the foregoing SUCH WARRANTIES DO NOT COVER Coated incandescent light bulbs fluorescent...

Page 15: ...ire rideau d air chaud Informations Importantes pour le Propri taire 15 Introduction 15 Consignes de S curit Importantes 16 Description du Mod le 17 D signation du Mod le 17 Caract ristiques Technique...

Page 16: ...ion de format et de configuration des broches corrects Si la fiche et la prise ne se correspondent pas s adresser un lectricien qualifi pour d terminer et installer une prise de courant de format et d...

Page 17: ...ateaux de demi taille Les appareils humidifi s sont disponibles en version remplissage automatique ou manuel les deux pouvant contenir 9 litres 2 1 4 gallons Le FSHACH 2 mod le deux plateaux est dot d...

Page 18: ...s appareils sont fournis par l usine avec un cordon et une prise lectrique install s les prises fournies varient selon les applications AVERTISSEMENT DANGER DE D CHARGE LECTRIQUE Brancher l appareil s...

Page 19: ...24 3 8 673 mm 26 1 2 152 mm 6 464 mm 18 1 4 478 mm 18 3 4 FSHAC 2PT 610 mm 24 737 mm 29 864 mm 34 456 mm 18 114 mm 4 1 2 562 mm 22 1 8 664 mm 26 1 8 FSHACH 2PT 610 mm 24 737 mm 29 908 mm 35 3 4 456 mm...

Page 20: ...e AVERTISSEMENT DANGER DE D CHARGE LECTRIQUE Brancher l appareil sur une prise de courant avec terre de tension de format et de configuration des broches corrects Si la fiche et la prise ne se corresp...

Page 21: ...e d eau en appuyant sur le raccord de l appareil NOTA Installez la cartouche de filtrage avec la fl che de d bit dirig e vers l quipement 3 Ins rez compl tement le tuyau d alimentation en eau dans la...

Page 22: ...pareil refroidisse NOTA Un ventilateur de refroidissement l int rieur de l appareil continuera fonctionner pendant un court moment apr s l arr t de l appareil 2 Effectuez la proc dure de Nettoyage quo...

Page 23: ...t non abrasif Remplacent de la cartouche de filtrage Mod les humidifi s uniquement Hatco R f 03 05 079 00 Remplacez la cartouche de filtrage dans l un des cas suivants Une baisse notable du d bit d ea...

Page 24: ...ncentration excessive de calcaire ou de min raux suivez la proc dure RETRAIT DES D P TS DE CALCAIRE ET DE MIN RAUX pour le nettoyage et le d tartrage p riodiques du r servoir d eau NOTA Les dommages c...

Page 25: ...ez les modifications n cessaires loignez les ventilateurs portatifs Fermez toutes les fen tres et portes Fermez la fen tre du guichet de vente emporter V rifiez les trappes d a ration au plafond et r...

Page 26: ...ateaux Des plateaux en aluminium sont disponibles directement aupr s de Hatco Commander un article en stock Hatco 18 Sheet Pan Plateau de dimension ordinaire 457 x 660 mm 18 x 26 Plateau de dimension...

Page 27: ...EVETS OU TOUTES AUTRES ATTEINTES AUX DROITS DE LA PROPRI T INTELLECTUELLE Sans restreindre la port e g n rale des nonc s pr c dents CES GARANTIES NE COUVRENT PAS LES L MENTS SUIVANTS ampoules d claira...

Page 28: ...Sauquoit 800 836 1014 J B Brady Inc Syracuse 315 422 9271 NORTH CAROLINA Authorized Appliance Charlotte 704 377 4501 OHIO Akron Canton Comm Svc Inc Akron 330 753 6634 Tech 24 Cincinnati 513 772 6600...

Reviews: