background image

Form No. CWBM-1120

3

English

IMPORTANT SAFETY INFORMATION

WARNING

ELECTRIC SHOCK HAZARD:

  •  Plug unit into a properly grounded electrical receptacle 

of the correct voltage, size, and plug configuration. If 

plug and receptacle do not match, contact a qualified 

electrician to determine and install proper voltage and 

size electrical receptacle.

  •  Turn OFF power switch and disconnect unit from power 

source before performing any cleaning, adjustments, 

or maintenance.

  •  Unit is not weatherproof. Locate unit indoors.
  •  DO NOT submerge or saturate with water. Unit is not 

waterproof. Do not operate if unit has been submerged 

or saturated with water.

  •  This unit is not “jet-proof” construction. Do not use jet-

clean spray to clean this unit.

  •  Discontinue use if power cord is frayed or worn.
 • Do not attempt to repair or replace a damaged 

power cord. The cord must be replaced by Hatco, an 

Authorized Hatco Service Agent, or a person with 

similar qualifications.

  •  This unit must be serviced by qualified personnel only. 

Service by unqualified personnel may lead to electric 

shock or burn.

  • Use only Genuine Hatco Replacement Parts when 

service is required. Failure to use Genuine Hatco 

Replacement Parts will void all warranties and may 

subject operators of the equipment to hazardous 

electrical voltage, resulting in electrical shock or burn. 

Genuine Hatco Replacement Parts are specified to 

operate safely in the environments in which they are 

used. Some aftermarket or generic replacement parts 

do not have the characteristics that will allow them to 

operate safely in Hatco equipment.

FIRE HAZARD:

  •  Install  unit  with  a  minimum  of  2″  (51  mm)  of  space 

between all sides of condensing unit and any 

combustible surfaces.

  •  Do not use flammable cleaning solutions to clean this 

unit.

EXPLOSION HAZARD: Do not store or use gasoline or 

other flammable vapors or liquids in the vicinity of this or 

any other appliance.
This unit must be installed by qualified, trained installers. 

Installation must conform to all local electrical and 

plumbing codes. Check with local plumbing and electrical 

inspectors for proper procedures and codes.
Make sure food product has been chilled to the proper 

food-safe temperature before placing in the unit. Failure 

to chill food product properly may result in serious health 

risks. This unit is for holding pre-chilled food product only.
Hatco Corporation is not responsible for actual food 

product serving temperature. It is the responsibility of the 

user to ensure that food product is held and served at a 

safe temperature.

WARNING

Make sure all operators have been instructed on the safe 

and proper use of the unit.
This unit is not intended for use by children or persons 

with reduced physical, sensory, or mental capabilities. 

Ensure proper supervision of children and keep them 

away from the unit.
Maintain proper cleanliness of the unit. Proper cleanliness 

and sanitation is critical for food-safe operation. Refer to 

the MAINTENANCE section for cleaning procedures. 
This unit has no “user-serviceable” parts. If service 

is required on this unit, contact an Authorized Hatco 

Service Agent or contact the Hatco Service Department at  

800-558-0607 or 414-671-6350.

CAUTION

Locate unit at the proper counter height in an area that is 

convenient for use. Location should be level and strong 

enough to support weight of unit and contents.

NOTICE

This unit is designed for use in environments where ambient 

temperature is between 65°F (18°C) and 86°F (30°C). 
When shipped during cold weather months, store unit in 

proper ambient temperature environment for 10 hours to 

prevent compressor and/or refrigerant line damage. If unit 

is turned on and there is excessive noise and vibration, 

turn off immediately and allow additional warm up time.
Provide louvered or grill-style openings with a minimum 

size  of  12″  x  12″/144  square  inches  (31  x  31  cm/

 

961 square cm) in the cabinetry in front of and behind the 

condensing unit for proper ventilation. Failure to provide 

adequate air flow through the condensing unit may cause 

unit failure and will void the unit warranty.
Do not recirculate exhaust air inside cabinet when multiple 

refrigerated wells are installed together. Intake air should 

enter from outside of cabinet.
Transport and install unit in upright position only. Failure 

to do so may result in damage to refrigeration system.
Use caution and avoid hitting condensing unit hoses/lines 

when installing unit. Damage caused during installation is 

not covered under warranty.
Do not locate unit in an area subject to excessive 

temperatures or grease from grills, fryers, etc. Excessive 

temperatures could cause damage to the unit. 
Clean unit daily to avoid malfunctions and maintain 

sanitary operation.
Use non-abrasive cleaners and cloths only. Abrasive 

cleaners and cloths could scratch finish of unit, marring its 

appearance and making it susceptible to soil accumulation.
Do not use steel wool for cleaning. Steel wool will scratch 

the finish.
Do not use harsh chemicals such as bleach, cleaners 

containing bleach, or oven cleaners to clean the unit.

Read the following important safety information before using this equipment to avoid serious 

injury or death and to avoid damage to equipment or property.

Summary of Contents for CWB Series

Page 1: ...menos que haya le do y comprendido el contenido de este manual Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesi n o muerte Este manual...

Page 2: ...optimum performance Every unit is inspected and tested thoroughly prior to shipment This manual provides the installation safety and operating instructions for the Refrigerated Drop In Wells Hatco re...

Page 3: ...rved at a safe temperature WARNING Make sure all operators have been instructed on the safe and proper use of the unit This unit is not intended for use by children or persons with reduced physical se...

Page 4: ...tifies products designed to reflect Hatco s commitment to improving protecting and preserving the global environment Hatco Refrigerated Drop In Wells qualify for the ecoization logo through the use of...

Page 5: ...o BS 1363 AS 3112 270 lbs 122 kg 5 8 hp 60 1956 2138 2328 8 9 9 3 9 7 CEE 7 7 Schuko BS 1363 CWB 6 5 8 hp 120 60 800 8 7 NEMA 5 15P 313 lbs 142 kg 1 2 hp 220 230 240 50 826 904 984 3 8 3 9 4 1 CEE 7 7...

Page 6: ...5 1143 mm 27 686 mm 25 1 2 648 mm 12 305 mm SPECIFICATIONS D C A Front View Model CWB 6 Side View Model CWB 6 B 2 3 4 70 mm Dimensions Refrigerant Information Hatco Refrigerated Drop In Wells use R 51...

Page 7: ...ntil the unit and the installation site are completely prepared for the unit to be installed 1 Remove all external packaging from the unit 2 Remove tape protective packaging and literature from all su...

Page 8: ...installed in the openings to protect the condensing unit Openings should be a minimum of 12 x 12 31 x 31 cm or 144 square inches 961 square cm One opening should be located in front of the condenser...

Page 9: ...ol box in a horizontal surface may result in the collection of liquids and lead to electric shock 1 Cut and drill the appropriate holes in the mounting surface Refer to the Control Box Cutout and Scre...

Page 10: ...digital temperature controller will energize and ON will appear on the display followed by the current temperature of the unit The symbol on the display will illuminate to show the condensing unit is...

Page 11: ...y until the number 22 appears on the display then press the key 4 Use the or key to scroll through the programmable parameters until dI defrost interval appears on the display 5 Press the key to selec...

Page 12: ...ld detergent Use a plastic scouring pad to remove any hardened food particles or mineral deposits 4 Wipe down well with a clean sanitized cloth to remove the detergent residue Repeat until all deterge...

Page 13: ...ve noise and vibration when turned on Internal components have not been adequately warmed before operation Turn off unit immediately Unit should be stored in a warm environment of 65 F 18 C for at lea...

Page 14: ...Pan 2 1 2 64 mm Deep Full Pan 4 102 mm Deep Full Pan 6 152 mm Deep Stainless Steel Food Pans False Bottom False bottoms are accessories available for all models False bottoms allow better drainage fo...

Page 15: ...nt caused by liming sediment buildup chemical attack or freezing or Product misuse tampering or misapplication improper installation or application of improper voltage 2 LIMITATION OF REMEDIES AND DAM...

Page 16: ...e et d essais pratiques Les mat riaux utilis s ont t s lectionn s pour une durabilit maximale une apparence attractive et des performances optimales Chaque appareil est soigneusement inspect et test...

Page 17: ...erie et en lectricit AVERTISSEMENT Assurez vous que les aliments ont t correctement r frig r s une temp rature appropri e avant de les placer dans l appareil Maintenir des aliments une temp rature ina...

Page 18: ...a sortie de l usine avec le nombre ad quat de barres de support de bacs de 20 508 mm en fonction de la contenance des bacs du mod le Chaque cuve peut accueillir diff rentes combinaisons de bacs de gra...

Page 19: ...chuko BS 1363 CWB 6 5 8 hp 120 60 800 8 7 NEMA 5 15P 142 kg 313 lbs 1 2 hp 220 230 240 50 826 904 984 3 8 3 9 4 1 CEE 7 7 Schuko BS 1363 AS 3112 142 kg 313 lbs 5 8 hp 60 1956 2138 2328 8 9 9 3 9 7 CEE...

Page 20: ...globale C Hauteur de la cuve D CWB 1 483 mm 19 686 mm 27 648 mm 25 1 2 305 mm 12 CWB 2 813 mm 32 686 mm 27 648 mm 25 1 2 305 mm 12 CWB 3 1143 mm 45 686 mm 27 648 mm 25 1 2 305 mm 12 CARACT RISTIQUES T...

Page 21: ...r dans le groupe compresseur condenseur pourrait entra ner une panne de l appareil et aurait pour effet d annuler la garantie AVIS Maintenez l appareil dans la position verticale lors du transport et...

Page 22: ...h ssis du groupe compresseur condenseur sur l enceinte de la cuve 5 l aide des deux boulons du panneau de contr le refixez le panneau de contr le sur le ch ssis du groupe compresseur condenseur Groupe...

Page 23: ...tallez pas le panneau de contr le devant les serpentins du condenseur Le panneau de contr le peut tre install une distance inf rieure 1219 mm 48 du groupe compresseur condenseur 4 Connectez le raccord...

Page 24: ...mensions de d coupe 2 Retirez le bo tier de commande de l unit en retirant les boulons sur le c t du groupe de condensation 3 Retirez les quatre vis du couvercle du bo tier de commandes et retirez le...

Page 25: ...est activ et refroidit la cuve NOTA Cet appareil est pr r gl la sortie de l usine une temp rature nominale de 0 C 32 F Si les conditions ambiantes n cessitent un r glage de la temp rature nominale re...

Page 26: ...ran Pour la premi re mise en service de l appareil ce nombre sera O 6 Appuyez sur la touche ou dans les 60 secondes pour faire d filer le nombre d heures souhait entre chaque cycle de d givrage Voici...

Page 27: ...ticule solide de nourriture ou d p t de min raux 4 Essuyez la cuve l aide d un chiffon propre et d sinfect pour enlever toute trace de d tergent R p tez l op ration jusqu ce qu il n y ait plus aucune...

Page 28: ...avant la mise en service teignez imm diatement l appareil L appareil doit tre stock dans un environnement chaud une temp rature de 65 F 18 C pendant au moins 10 heures OFF clignote sur l cran de comm...

Page 29: ...profondeur largeur x profondeur x hauteur 12 3 4 x 20 3 4 x 4 324 x 527 x 102 mm HDW 6 PAN Bac en acier inoxydable grande taille 6 152 mm de profondeur largeur x profondeur x hauteur 12 3 4 x 20 3 4 x...

Page 30: ...dition 2 Appliquez un agent d tanch it base de silicone homologu par la NSF sur les bords de l appareil pour le fixer la base inclin e 3 Appliquez un agent d tanch it base de silicone homologu par la...

Page 31: ...VETS OU TOUTES AUTRES ATTEINTES AUX DROITS DE LA PROPRI T INTELLECTUELLE Sans restreindre la port e g n rale des nonc s pr c dents CES GARANTIES NE COUVRENT PAS LES L MENTS SUIVANTS ampoules d clairag...

Page 32: ...uis 314 535 2222 NEBRASKA Anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEY Jay Hill Repair Fairfiel...

Reviews: