background image

2

Form No. CWBSM-0120

English

Important Owner Information ..............................................2

Introduction ...........................................................................2

Important Safety Information ..............................................3

Model Description ................................................................4

Model Designation ...............................................................5

Specifications .......................................................................5

Plug Configuration ...............................................................5

Electrical Rating Chart .........................................................5

Refrigerant Information ........................................................5

Dimensions ..........................................................................6

Installation .............................................................................7

General ................................................................................7

Preparing the Unit for Installation ........................................7

Preparing the Installation Site .............................................8

Installing the Unit .................................................................8

Installing the Control Panel Remotely .................................9

Countertop Cutout Dimensions ...........................................9

Operation .............................................................................10

General ..............................................................................10

Changing the Setpoint Temperature .................................. 11

Setting the Auto-Defrost Cycle .......................................... 11

Changing Fahrenheit and Celsius Setting ......................... 11

Maintenance ........................................................................12

General ..............................................................................12

Daily Cleaning ...................................................................12

Monthly Cleaning ...............................................................12

Troubleshooting Guide ......................................................13

Options and Accessories ..................................................14

Limited Warranty ................................................................15

Authorized Parts Distributors ...........................Back Cover

IMPORTANT OWNER INFORMATION

INTRODUCTION

Hatco Slim Refrigerated Drop-In Wells are specially designed 

to hold cold foods at safe serving temperatures while providing 

easy, reachable access to all items in the well. The insulated, 

top-mount units are available in one through four pan 

configurations. A unique top bezel design allows cold air to 

effectively blanket the food product inside the refrigerated well. 

In addition, the bezel design provides clear viewing and easy 

access to the food contents of the refrigerated well.
All models are equipped with a condensing unit that can 

be rotated to accommodate the installation location. The 

condensing units on the two, three, and four pan models also 

can be moved between the center of the unit and the evaporator 

coil connection for additional installation flexibility.
Hatco Slim Refrigerated Drop-In Wells are a product of extensive 

research and field testing. The materials used were selected 

for maximum durability, attractive appearance, and optimum 

performance. Every unit is inspected and tested thoroughly prior 

to shipment.

This manual provides the installation, safety, and operating 

instructions for the Slim Refrigerated Drop-In Wells. Hatco 

recommends all installation, operating, and safety instructions 

appearing in this manual be read prior to installation or 

operation of a unit.
Safety information that appears in this manual is identified by 

the following signal word panels:

WARNING

WARNING indicates a hazardous situation which, if not 

avoided, could result in death or serious injury.

CAUTION

CAUTION indicates a hazardous situation which, if not 

avoided, could result in minor or moderate injury.

NOTICE

NOTICE is used to address practices not related to 

personal injury.

Record the model number, serial number, voltage, and 

purchase date of the unit in the spaces below (specification 

label located on bottom of unit and back of control panel). 

Please have this information available when calling Hatco for 

service assistance.
Model No. _______________________________________
Serial No. ________________________________________
Voltage __________________________________________
Date of Purchase __________________________________

Register your unit!

Completing online warranty registration will prevent delay in 

obtaining warranty coverage. Access the Hatco website at 

www.hatcocorp.com

, select the 

Support 

pull-down menu, 

and click on “Warranty”.

Business 

Hours: 

7:00 

am

 to 5:00 

pm

 Monday

Friday, 

 

Central Time (CT)

 

(Summer Hours 

— 

June to September

:

 7:00 

am

 to 5:00 

pm

 Monday

Thursday 

 7:00 

am

 to 4:00 

pm

 Friday)

Telephone: 800-558-0607; 414-671-6350
E-mail: [email protected]

24 Hour 7 Day Parts and Service

Assistance available in the United States

and Canada by calling 800-558-0607.

Additional information can be found by visiting our web site at 

www.hatcocorp.com

.

CONTENTS

Summary of Contents for CWB-S Series

Page 1: ...equipo al menos que haya le do y comprendido el contenido de este manual Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesi n o muerte Est...

Page 2: ...e selected for maximum durability attractive appearance and optimum performance Every unit is inspected and tested thoroughly prior to shipment This manual provides the installation safety and operati...

Page 3: ...re all operators have been instructed on the safe and proper use of the unit WARNING This unit is not intended for use by children or persons with reduced physical sensory or mental capabilities Ensur...

Page 4: ...Corian Swanstone etc Hatco Slim Refrigerated Drop In Wells are designed manufactured and tested to maintain safe food holding temperatures The ecoization logo identifies products designed to reflect H...

Page 5: ...8 8 9 9 3 9 7 CEE 7 7 Schuko BS 1363 MODEL DESIGNATION SPECIFICATIONS C W B S x Cold Well Built In Slim Full Size Pan Capacity Electrical Rating Chart Plug Configuration Units are supplied from the fa...

Page 6: ...View Model CWB S4 Side View Model CWB S4 B 2 3 4 70 mm 17 3 8 441 mm 9 1 8 232 mm 15 7 16 392 mm 17 430 mm 2 3 4 70 mm Dimensions Subtract 7 1 2 190 mm from Overall Height C when control box is remote...

Page 7: ...packaging from the unit 2 Remove tape protective packaging and literature from all surfaces of the unit NOTE To prevent delay in obtaining warranty coverage complete online warranty registration See t...

Page 8: ...the desired location The control panel can be installed on one of three sides of the condensing unit support frame Do not install the control panel in front of the condenser coils The control panel ca...

Page 9: ...Refer to the Control Panel Cutout and Screw Hole Dimensions chart for the cutout dimensions 2 Remove the control box from the unit by removing the bolts on the side of the condensing unit 3 Remove th...

Page 10: ...he digital temperature controller will energize and ON will appear on the display followed by the current temperature of the unit The symbol on the display will illuminate to show the condensing unit...

Page 11: ...y until the number 22 appears on the display then press the key 4 Use the or key to scroll through the programmable parameters until dI defrost interval appears on the display 5 Press the key to selec...

Page 12: ...ld detergent Use a plastic scouring pad to remove any hardened food particles or mineral deposits 4 Wipe down well with a clean sanitized cloth to remove the detergent residue Repeat until all deterge...

Page 13: ...ive noise and vibration when turned on Internal components have not been adequately warmed before operation Turn off unit immediately Unit should be stored in a warm environment of 65 F 18 C for at le...

Page 14: ...eep Full Pan 6 152 mm Deep Stainless Steel Food Pans Slanted Base Option Slanted bases are options available for all models The slanted base gives the well a 5 tilt NOTE Water will not completely drai...

Page 15: ...ARTICULAR PURPOSE OR PATENT OR OTHER INTELLECTUAL PROPERTY RIGHT INFRINGEMENT Without limiting the generality of the foregoing SUCH WARRANTIES DO NOT COVER Coated incandescent light bulbs fluorescent...

Page 16: ...le r sultat d une recherche avanc e et d essais pratiques Les mat riaux utilis s ont t s lectionn s pour une durabilit maximale une apparence attractive et des performances optimales Chaque appareil e...

Page 17: ...erie et en lectricit AVERTISSEMENT Assurez vous que les aliments ont t correctement r frig r s une temp rature appropri e avant de les placer dans l appareil Maintenir des aliments une temp rature ina...

Page 18: ...bre service est fourni la sortie de l usine avec le nombre ad quat de barres de support de bacs de 305 mm 12 en fonction de la contenance des bacs du mod le Chaque cuve peut accueillir diff rentes com...

Page 19: ...gr e Slim allong es Contenance du bac grande taille Tableau des valeurs nominales lectriques Configuration des fiches Les appareils sont livr s avec un cordon lectrique avec fiche Diff rentes fiches...

Page 20: ...RTISSEMENT DANGER DE D CHARGE LECTRIQUE Brancher l appareil sur une prise de courant avec terre de tension de format et de configuration des broches corrects Si la fiche et la prise ne se corresponden...

Page 21: ...t tre orient 90 ou 180 de sa position originale la sortie de l usine Sur les mod les CWB S2 S3 et S4 le groupe compresseur condenseur peut galement tre install dans diff rentes positions entre le cent...

Page 22: ...voulu Le panneau de contr le peut tre install sur un des trois c t s du cadre de soutien du groupe compresseur condenseur N installez pas le panneau de contr le devant les serpentins du condenseur Le...

Page 23: ...es de passage de vis et de d coupe pour le panneau de commande pour obtenir les dimensions de d coupe 2 Retirez le bo tier de commande de l unit en retirant les boulons sur le c t du groupe de condens...

Page 24: ...est activ et refroidit la cuve NOTA Cet appareil est pr r gl la sortie de l usine une temp rature nominale de 32 F 0 C Si les conditions ambiantes n cessitent un r glage de la temp rature nominale rep...

Page 25: ...cran Pour la premi re mise en service de l appareil ce nombre sera 0 6 Appuyez sur la touche ou dans les 60 secondes pour faire d filer le nombre d heures souhait entre chaque cycle de d givrage Voici...

Page 26: ...rticule solide de nourriture ou d p t de min raux 4 Essuyez la cuve l aide d un chiffon propre et d sinfect pour enlever toute trace de d tergent R p tez l op ration jusqu ce qu il n y ait plus aucune...

Page 27: ...s avant la mise en service teignez imm diatement l appareil L appareil doit tre stock dans un environnement chaud une temp rature de 65 F 18 C pendant au moins 10 heures OFF clignote sur l cran de com...

Page 28: ...64 mm 2 1 2 de profondeu Bac grande taille 102 mm 4 de profondeu Bac grande taille 152 mm 6 de profondeu Bacs alimentaires en acier inoxydable Base inclin e en option Les bases inclin es sont disponib...

Page 29: ...VETS OU TOUTES AUTRES ATTEINTES AUX DROITS DE LA PROPRI T INTELLECTUELLE Sans restreindre la port e g n rale des nonc s pr c dents CES GARANTIES NE COUVRENT PAS LES L MENTS SUIVANTS ampoules d clairag...

Page 30: ...30 Formulaire n CWBSM 0120 Fran ais Fran ais NOTAS...

Page 31: ...Form No CWBSM 0120 31 English NOTES English...

Page 32: ...e Plattsburgh 800 634 5005 Duffy s AIS Sauquoit 800 836 1014 J B Brady Inc Syracuse 315 422 9271 NORTH CAROLINA Authorized Appliance Charlotte 704 377 4501 OHIO Akron Canton Comm Svc Inc Akron 330 753...