CONTROL UNIT
11
4
With the gear disengaged and the Control
Unit’s pointing in the upper most position,
make sure that the D-Cut in the Volume pot is
positioned as it is in FIG 11-3b
5
Engage the gears and tighten the two previously loosened screws.
6
Move the Control Unit up and down and check that the gears move smoothly.
7
Reattach the Control Unit, then turn on the power and adjust the volume value on the calibration screen.
FIG. 11-3b Y Axis (Up and Down) Volume
Position of Volume axis D cut face when
controller pointing upper most postion.
1
Turn off the power and remove the Control Unit
(see 11-1).
2
Locate the X axis volume - positioned at the
rear base of the controller.
3
Unscrew the (2) hex nut from the volume pot
bracket. Disconnect the harness and remove.
Replace
FIG. 11-3c
Imperial Hex Nut.