37
DIGITAL READ OUT (OPTIONAL)
RE-ADJUST ABSOLUTE REFERENCE POINT
Re-adjust the absolute reference point when
bottom supports are smoothened or when
the midway fences are smoothened. Check
the absolute reference point when battery is
replaced.
1
Disconnect the machine of the mains
supply.
2 Put the saw unit in horizontal position.
3 Press the F-button for 3 seconds, the
digital read out shows: ConF.
4
Press several times shortly the F-button
until the display shows P 09.
5
Press one more time the F-button, the
digital read out shows the current
absolute reference point.
6
Use the and button to change the
value to 000000.0
7
Press several times shortly the F-button
until the display shows P 24.
8 Press the F-button one more time.
9 Use the and button to change the
value to 000000.0
10 Press several times shortly the F-button
until the digital read out shows the
normal measuring again.
11 Position the saw blade on the bottom
supports.
12 The digital display shows a value that
starts with a minus. Write this value down
on a piece of paper.
13 Press the F-button for 3 seconds, the
digital read out shows: ConF.
14 Press several times shortly the F-button
until the display shows P 09.
15 Press one more time the F-button, the
digital read out shows 000000.0
16 Use the and button to change the
value to the value that was written down
on the paper (without the minus).
17 Press several times shortly the F-button
until the digital read out shows the
normal measuring again.
18 Re-adjust the reference point of the
midway fences.
Summary of Contents for ORCA 1850
Page 2: ...2 Orca Eng 9 2004...
Page 39: ...39 EXPLODED VIEW TYPE ORCA...
Page 41: ...41 EXPLODED VIEW FRAME...
Page 52: ...52 EXPLODED VIEW TRANSPORT ROLLERS OPTIONAL...
Page 54: ...54 EXPLODED VIEW LENGTH STOP 60 90 50 20 10 70 80 40 100 110 120 30...
Page 59: ...59 EXPLODED VIEW STOPS FOR HORIZONTAL CUTS 10 30 20 80 40 60 90 50 70...
Page 61: ...61 EXPLODED VIEW HINGE FENCE OPTIONAL 80 120 40 10 60 70 50 20 30 140 130 90 100 110...
Page 63: ...63 EXPLODED VIEW EXTRACTION PIPE 20 30 40 70 80 90 50 60 170 160 150 120 10 110 140 130 100...
Page 69: ...69 EXPLODED VIEW REITERATION STOP 10 80 90 100 40 70 60 50 30 20 120 110...
Page 71: ...71 EXPLODED VIEW HOUSING...
Page 75: ...75 EXPLODED VIEW SPINDLE WITHOUT SCORING UNIT...
Page 76: ...76 EXPLODED VIEW SPINDLE WITH SCORING UNIT OPTIONAL...