7
Installation of End of Bale Sensor
The end of bale sensor determines the position of the needles on the baler. When the needles cycle the
sensor communicates this information to the Dual Channel Processor. This information is used for job records
and will be used by the optional Bale Identification systems. Follow the steps below to mount the sensor.
End of bale sensor bracket (001-4648) will be used. Cutoff excess metal not used during installation.
A
B
C
4-
7/8”
(13cm)
3-
1/8”
(8cm)
15”
(37cm)
Mount the end of bale sensor bracket (001-
4648) as shown. Mark and drill two 5/16” (8mm) holes and attach
the bracket using two 1/4” x 1” bolts, locks, flats, and nuts. Mount the sensor in the 8” (20cm) hole location,
keep the sensor 1/4" (7mm) from the needle and tighten both nuts. Cut off excess metal past the sensor. Run
the sensor cable up to the Dual Channel Processor and secure to the baler.
Sensor hole location
8 (20cm)”
001-
4648 with 6” (15cm)
hole used for sensor
001-
4648 with 12” (30cm)
hole used for sensor
Summary of Contents for 602A