background image

17 

 

Parts Breakdown 

 

Star Wheel Moisture Sensor and Bale Rate Sensors 

 

     

                          

 

Ref 

Description 

Part# 

Qty 

 

Ref 

Description 

Part# 

Qty 

Block cover 

006-4641B 

 

Star wheel block 

006-4641A 

Electronic swivel 

006-4642A 

 

10 

Star wheel sensor 

030-4641C 

Swivel insert 

w/ Ref # 10 

 

11 

Twine guard-left for AGCO 

001-4645H 

Snap ring (per side) 

006-4641K 

 

 

Twine guard-right for 

AGCO

  001-4644H 

Washer (per side) 

w/006-4641K 

 

 

(w/bale rate sensor holes) 

 

 

Dust seal (per side) 

w/006-4641K 

 

 

 

 

 

Plug fitting 

003-F38 

  1-10  Star wheel assembly 

030-4641 

Wiring grommet 

008-0821A 

 

 

 

 

 

 
 

                  

 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Ref 

Description 

Part# 

Qty 

12 

Bale rate sensor 

006-7303S 

13 

Moisture and bale 
rate harness 

006-7303H 

13 

12 

10 

11 

Summary of Contents for 602A

Page 1: ...1 602A 17 INST Imp Metric 6 22 Installation Manual Model 602A Microwave Moisture Bale Chute System AGCO 2100 2200 Series Balers Forage Harvester...

Page 2: ...ication preservatives for hay Harvest Tec system meets the Directive 2006 42 EC of the European Parliment and the Council of 17 May 2006 and other applicable European Directives including Directive 20...

Page 3: ...d Bale Rate Harness 8 Installation of the Main Harness the Power Communication Harness 8 Installation of Bluetooth Receiver 8 Microwave Sensor Installation 9 10 Wiring Diagram 11 Pin Outs 12 14 Common...

Page 4: ...back of the manual Right and Left sides are determined by facing in the direction of forward travel System Requirements The Baler Processor must have Version 3 3 or higher C1000 monitor must have Vers...

Page 5: ...wn are on the right twine box looking at the back of the baler Mark and drill the four 3 8 10mm holes and install DCP with four 5 16 x 1 bolts locks flats and nuts If your baler is not listed below mo...

Page 6: ...otch must be moved out an additional 1 2 13mm Use the template in the back of the manual for hole spacing Place the spacer plate 001 6707E over the precut holes Attach with 5 16 x 1 2 Allen head bolts...

Page 7: ...ill be used Cutoff excess metal not used during installation A B C 4 7 8 13cm 3 1 8 8cm 15 37cm Mount the end of bale sensor bracket 001 4648 as shown Mark and drill two 5 16 8mm holes and attach the...

Page 8: ...e the Bluetooth Receiver 030 6672B Recommended location is as close to the iPad being used as possible Connect the Power Communication harness 006 6650TM E to the bottom of the receiver right New for...

Page 9: ...650MWL in the kit Start by locating the connector with the white heat shrink label marked RX Connect this connector to the sensor mounted on the right side chute 006 4641MRX If connecting to a moistur...

Page 10: ...er Connect an extension harness and route to rear of baler Secure with cable ties Route the rest of the harness along the existing wiring toward the top of the chamber The wire from the stuffer sensor...

Page 11: ...ce on the tractor 9 Connect the Chute Wire Harness 006 6650MWL into the Pump Controller port on the DCP 10 Connect Microwave Sensors 006 4641MTX 006 4641MRX to the Chute Wire Harness 11 Connect the St...

Page 12: ...wer Pin 4 Gray Shield Pin 5 Green HT Can Low Pin 6 Yellow HT Can Hi Pin 7 Orange Can1 Hi Pin 8 Black Ground from TSD Pin 9 Black Ground from DCP Pin 10 Blue Can1 Low Bluetooth Receiver on Harness 006...

Page 13: ...wer Connector on Dual Channel Processor DCP Pin 1 Red 12V Power from tractor Pin 2 Black Ground from tractor Pin 3 Orange Keyed power Star Wheel and Bale Rate Sensor Connector on DCP Pin 1 Blue 12V Po...

Page 14: ...mpression Chamber Harness 006 6650MWL Pin 1 Red Power Pin 2 Black Ground Pin 3 N A Not Used Pin 4 Brown Signal Microwave Pre Compression Chamber Harness 006 6650MWL RX Pin 1 Black Ground Pin 2 Red Pow...

Page 15: ...erformed A zero adjust should be performed on initial installation It is also recommended during a zero adjust calibration at the beginning of each season 10 When reading moisture with microwave senso...

Page 16: ...ltage should be constant between 12 and 14 volts 3 Install voltage surge protection on tractors alternator Display reads under or over power 1 Verify with multi meter actual voltage Voltage range shou...

Page 17: ...l insert w Ref 10 2 11 Twine guard left for AGCO 001 4645H 1 4 Snap ring per side 006 4641K 2 Twine guard right for AGCO 001 4644H 1 5 Washer per side w 006 4641K 2 w bale rate sensor holes 6 Dust sea...

Page 18: ...r 001 5650X 1 5 DCP Main Control LS 600 AUTO 006 6671LS 1 6 DCP Baler Harness 30 FT 006 6650LS2 E 1 7 DCP Tractor Harness 006 6650TM E 1 8 Dust Plugs 006 5651PLUGS 1 9 DCP Baler Interface Harness 006...

Page 19: ...MTX 1 3 End of Bale Extension Harness 20 006 7400MXT 1 4 MWM Pre Compression Harness 006 6650MWL 1 5 Microwave RX Sensor 006 4641MRX 1 6 End of Bale Bracket Stuffer Bracket 001 4648SS 1 7 End of Bale...

Page 20: ...g plastic nut from USB plug before connecting the wires Black White 5 The wires will then be hooked to the designated terminals on the bottom of the USB plug 6 Drill a 1 1 8 hole in the preferred moun...

Page 21: ...ove the round locking plastic nut from USB plug before connecting the wires Black White 5 The wires will then be hooked to the designated terminals on the bottom of the USB plug 6 Drill a 1 1 8 hole i...

Page 22: ...22 Notes...

Page 23: ...to deny the warranty request at their discretion Parts must be returned through the selling dealer and distributor transportation charges prepaid This warranty shall not be interpreted to render Harve...

Page 24: ...24 HARVEST TEC LLC P O BOX 63 2821 HARVEY STREET HUDSON WI 54016 PHONE 715 386 9100 1 800 635 7468 FAX 715 381 1792 Email info harvesttec com...

Reviews: