15
Operation Instructions
Automatic mode will allow you to view the moisture information, baling rate and stroke counts.
Automatic Mode
After pushing the AUTOMATIC MODE key in the Main Menu screen, the following screen will appear:
iPad
1. To pause the unit while in operation select the Pause key.
2. Push the OVERRIDE key to turn on all three pumps at the same time for full output of the system. This
button is not used with a moisture only system.
3. Baling Rate and Application Rate are shown in the middle of the screen. Application rate will read zero with
moisture only system.
4. Volume used and strokes per bale are shown at the bottom of the screen will show accumulated pounds of
preservative used on the go. There will not be any information shown in the # Used section with a moisture
only unit.
5. The graph shows the moisture trend from the past 90 seconds in 3 second intervals.
6. The DCP button shown when using an iPad displays your connection signal with the Bluetooth receiver.
Green
– DCP is connected, Yellow – DCP is connecting, Red – DCP not connected.
7. Press the MAIN MENU key to return to the opening screen.
1
8
2
3
5
6
7
4