background image

 

©Hartenberger Unterwassertechnische Geräte GmbH   Rights reserved for technical changes.   Issue 01.2011

 

 Instructions for use   Hartenberger   High-Tech-UW-Lamp   nano compact 

 

REMOVING / REPLACING THE HALOGEN BULB 

The halogen bulb is accessible after opening the front and rear housing covers. 
Access to the halogen bulb stowage is easier when the rear housing cover is 
opened (see page 8). 

RISK OF INJURY THROUGH BURNING! 

The halogen bulb remains very hot for an extended period of time after use! 
Do not touch the halogen bulb with your bare fingers. Residue on your fingers can 
remain on the glass during normal use may form carbon. This will reduce the 
efficiency of the bulb. Use a clean cloth or tissue to remove the bulb from the 
socket. When refitting or replacing the bulb, ensure that it is located all the way 
into the socket. To produce an even illumination, it is imperative to ensure that the 
bulb sits upright in the socket. Assemble the lamp and check for correct fit and 
operation. 
To prevent plastic components and the cells of the lamp from overheating 
and becoming damaged by heat, the halogen bulb should only be switched 
on when the housing is completely assembled and all covers are screwed 
tight.
 

SPARE HALOGEN BULB 

There are 2 halogen bulb stowage compartments adjacent to the bulb socket. 
Bulbs are safely stowed in these compartments and the plastic cover prevents 
them from inadvertently falling out. This cover must be turned open to access the 
bulb stowage (see Fig.4, II). 

LED MODULE 

The optional LED-Module replaces the standard halogen bulb and front 
cover/reflector. The module is connected electrically by plugging it into the 
halogen bulb socket. (see fig. 4, III). The plug arrangement prevents incorrect 
fitting/connection. If the lamp does not function properly, remove the plug module, 
rotate it 180° and refit it into the halogen bulb s ocket. Take care not to short 
circuit the contacts. 

REAR HOUSING COVER (THREADED CAP) 

THE REAR HOUSING COVER SEALS 

The double O-ring seals on the charging socket, the over pressure indicator and 
the lamp conductor insert can only be replaced by the manufacturer.  
Based on the experience gained to date, this service work should be carried out 
every 4-5 years (with intensive use in diving schools, every 3 years).  
Our experience with other models indicates that these seals are in good condition 
after this period. 
Please get the latest information from our web site 
(http://www.hartenberger.de/pdf/e_bet_nano.pdf) on service intervals and 
recommended life spans the can change with time/experience. 
The plastic components on the rear housing cover should not be exposed 
to any solvent based agents, such exposure may result in cracks in the 
components and subsequent leakage/flooding. 

!

!

!

Summary of Contents for Nano compact

Page 1: ...Instruction for use Hartenberger Underwater Hand Lamp Hartenberger nano compact pressure indicator LED power control unlock lock OFF 25 LED 125 25 SOS 1 sec 0 5 sec 5 sec nano compact...

Page 2: ...ER 9 POWER PACK 11 PREPARATION FOR USE 11 USING THE UNDERWATER LAMP 12 TRANSPORT 15 STORAGE 16 CHARGING 16 CHARGER OFF SHORE I 6 19 CHARGER OFF SHORE II 20 CARE AND MAINTENANCE 21 FAULT DIAGNOSIS 22 S...

Page 3: ...rantee Any unauthorised work on the lamp i e the removal or tightening of screws or the removal of the guarantee seals will make the guarantee invalid Warning The manufacturer s warranty expires if th...

Page 4: ...TOR COVER The standard front cover is equipped with a spot reflector for use with halogen bulbs Flood reflectors and or chemically matt coated front glasses are available as options C FRONT HOUSING CO...

Page 5: ...cts are colour coded red right contact and blue left contact N MAGENTIC SWITCH TRANSPORT LOCK The magnetic switch is used for all the control functions of the lamp and the electronics To lock the lamp...

Page 6: ...bulb during transport V CELL PACK The cell pack is plugged in to the power pack and can be removed replaced in seconds The cell pack consists of a Lithium Manganese LiMn cell block a micro processor e...

Page 7: ...WEIGHT PRESSURE RATING Length Diameter weight on land weight in water Resistance to water Pressure 150mm x 59mm 6 x 2 0 6kg 1lb 5oz 0 2kg 7oz 100m 330 ft FRONT GLASS PLATE The nano compact lamps have...

Page 8: ...nt tool should be used for the removal of the O ring i e a wooden tooth pick Before the components are refitted it is recommended that a thin coating of silicone grease is applied as lubrication It is...

Page 9: ...rtments adjacent to the bulb socket Bulbs are safely stowed in these compartments and the plastic cover prevents them from inadvertently falling out This cover must be turned open to access the bulb s...

Page 10: ...O rings and its groove should be thoroughly cleaned Should the sealing surfaces and or components be damaged then all damaged parts should be replaced If the O ring 40 x 3 0 50 hardness and 48 x 1 6 5...

Page 11: ...t the 3 plugs on the rear housing cover are guided into the sockets carefully The plug arrangement prevents incorrect connection Push the cell pack fully down on to the pins without damaging distortin...

Page 12: ...22 TRANSPORT LOCK Release the transport lock immediately before use To unlock the switch push it from the transport lock position lock outwards unlock the switch must physically click into the unlock...

Page 13: ...s electronics will automatically sense a defective bulb and will automatically turn on all the LEDs This serves as an emergency source of light for reading instrumentation or for orientation in a very...

Page 14: ...ssary the lamp if possible after a short pause can be reactivated and will automatically turn on at 25 power setting The cells are almost certainly damaged should this mode of operation be selected If...

Page 15: ...de down with the glass plate pointing down and look at the glass plate from the side for any signs of moisture water ingress After each use the lamp should be thoroughly rinsed in clean fresh water Du...

Page 16: ...ARGING RE CHARGEABLE CELLS The lithium manganese re chargeable cells used in this lamp have been declared as gas and acid alkali sealed For this reason the electrolyte in the cells cannot escape and t...

Page 17: ...on a dry surface that is not sensitive Even gas tight lithium manganese cells may leak under certain conditions this leakage may cause damage to the surface the cell pack is placed on Note that a def...

Page 18: ...ONITORING DURING CHARGING The control module in the lamp monitors the temperature of the cell pack during charging If the temperature of the cell pack exceeds 60 C 140 F during charging the charge pro...

Page 19: ...e charger into the mains socket The charger is equipped with a standard euro 2 pin flat plug Other popular plug configurations are available and replace the euro plug simply by pulling it out and fitt...

Page 20: ...ry out a self test after which time the LEDs will illuminate Charger LEDs when charging NC or NMH re chargeable cells LED I Green Mains supply connected charger is functioning correctly Red Mains supp...

Page 21: ...Every time the lamp housing is opened latest after 6 months or 50 times use X Replace the O rings in the covers Every 12 months or earlier if damaged X Clean and dry external charging connections Befo...

Page 22: ...over and O ring 2 Return the lamp to the manufacturer for repair Lamp does not turn on 1 Cell pack is discharged 2 Bulb is defective 1 Charge the cell pack 2 Replace bulb Charging LED does not illumin...

Page 23: ...bags TRANSPORT BAG CHARGER Nylon bag offers protection whilst transporting the charger in diving gear bags CARABINER CLIPS For securing the lamp to a suitable point on the diving equipment CARABINER...

Page 24: ...for technical changes Issue 01 2011 24 Instructions for use Hartenberger High Tech UW Lamp nano compact Hartenberger Unterwassertechnische Ger te GmbH Rennebergstr 19 D 50939 K ln Germany Tel 49 221 4...

Reviews: