 Instructions for use   Hartenberger   High-Tech-UW-Lamp   nano compact 

BEFORE EACH USE 

Before each use, the threads, sealing surfaces and O-ring must be checked for 
integrity and cleanliness. (See Closing the housing, page 8). If the bulb has been 
removed for transport, it should be refitted into the socket. Refit the halogen bulb 
in the socket which may have been removed for transportation. Only release the 
transport lock to the unlocked position immediately before use. (See page 12).  

USING THE UNDERWATER LAMP 

Warning ! 

When the lamp is turned on, direct the beam away from yourself and others. 
Do not point the beam directly at others. If there is a defect on the lamp, the 
front glass plate may be forced out of the front of the housing with 
explosive force. 

Warning ! 

Water inside the housing (especially sea water) can have drastic results 
consequences after some a period if time. Therefore, during the use of the 
lamp please check repeatedly, whether water has found its way inside. Do 
this by holding the lamp on the slant pointing down, thus the ray of light 
pointing away from the body. Then look at the front glass from the side.  
If there is water inside the housing, bring the dive to an end by following the 
diving rules and open the housing as soon as possible 
(see page 22).  

TRANSPORT LOCK 

Release the transport lock immediately before use. 
To unlock the switch, push it from the transport lock position (lock) outwards 
(unlock) the switch must physically click into the unlocked position. 

MAGENTIC SWITCH / SWITCH UNIT 

The electronic controls are activated by pushing the switch to the right (+) or to 
the left (-). The signals are transmitted via magnetically sensitive hall sensors. 
This feature avoids any mechanical connection through the lamp’s housing 
reducing the risk of water ingress and general wear. 

ACTIVATING THE ELECTRONICS / CELL PACK CAPACITY DISPLAY 

If the switch is pushed to the left (-) for approx. 3 seconds, the electronics are 
activated from the energy saving „sleep” mode. The LED display illuminates and 
shows the charge status of the cell pack for approx 3 seconds. 
One LED = 25%,   two LED´s = 50%,   three LED´s = 75%,   four LED´s = 100% 
To view the capacity display after the 3 seconds, Slide the switch one short push 
to the left (-) again. 
If the lamp is not used for a period of 10 hours, the electronics will automatically 
return to the energy saving “sleep” mode. 

BRIGHTNESS / DIMMER 

The electronics allow the lamp to be used in 4 levels of brightness (50%, 75%, 
100% and using over voltage; 125%). 
Using the lamp at dimmed (lower) settings will save energy and extend the burn 
time of the lamp with one charge. 

If the switch is pushed for a short time (approx ½ second) to the right (+), the 
lamp will turn on to the first brightness stage (50%). 
Each subsequent push to the right (+) will increase the brightness 25%. 
Each subsequent push to the left (-) will decrease the brightness 25%. 

!

!

Summary of Contents for Nano compact

Page 1: ...Instruction for use Hartenberger Underwater Hand Lamp Hartenberger nano compact pressure indicator LED power control unlock lock OFF 25 LED 125 25 SOS 1 sec 0 5 sec 5 sec nano compact...

Page 2: ...ER 9 POWER PACK 11 PREPARATION FOR USE 11 USING THE UNDERWATER LAMP 12 TRANSPORT 15 STORAGE 16 CHARGING 16 CHARGER OFF SHORE I 6 19 CHARGER OFF SHORE II 20 CARE AND MAINTENANCE 21 FAULT DIAGNOSIS 22 S...

Page 3: ...rantee Any unauthorised work on the lamp i e the removal or tightening of screws or the removal of the guarantee seals will make the guarantee invalid Warning The manufacturer s warranty expires if th...

Page 4: ...TOR COVER The standard front cover is equipped with a spot reflector for use with halogen bulbs Flood reflectors and or chemically matt coated front glasses are available as options C FRONT HOUSING CO...

Page 5: ...cts are colour coded red right contact and blue left contact N MAGENTIC SWITCH TRANSPORT LOCK The magnetic switch is used for all the control functions of the lamp and the electronics To lock the lamp...

Page 6: ...bulb during transport V CELL PACK The cell pack is plugged in to the power pack and can be removed replaced in seconds The cell pack consists of a Lithium Manganese LiMn cell block a micro processor e...

Page 7: ...WEIGHT PRESSURE RATING Length Diameter weight on land weight in water Resistance to water Pressure 150mm x 59mm 6 x 2 0 6kg 1lb 5oz 0 2kg 7oz 100m 330 ft FRONT GLASS PLATE The nano compact lamps have...

Page 8: ...nt tool should be used for the removal of the O ring i e a wooden tooth pick Before the components are refitted it is recommended that a thin coating of silicone grease is applied as lubrication It is...

Page 9: ...rtments adjacent to the bulb socket Bulbs are safely stowed in these compartments and the plastic cover prevents them from inadvertently falling out This cover must be turned open to access the bulb s...

Page 10: ...O rings and its groove should be thoroughly cleaned Should the sealing surfaces and or components be damaged then all damaged parts should be replaced If the O ring 40 x 3 0 50 hardness and 48 x 1 6 5...

Page 11: ...t the 3 plugs on the rear housing cover are guided into the sockets carefully The plug arrangement prevents incorrect connection Push the cell pack fully down on to the pins without damaging distortin...

Page 12: ...22 TRANSPORT LOCK Release the transport lock immediately before use To unlock the switch push it from the transport lock position lock outwards unlock the switch must physically click into the unlock...

Page 13: ...s electronics will automatically sense a defective bulb and will automatically turn on all the LEDs This serves as an emergency source of light for reading instrumentation or for orientation in a very...

Page 14: ...ssary the lamp if possible after a short pause can be reactivated and will automatically turn on at 25 power setting The cells are almost certainly damaged should this mode of operation be selected If...

Page 15: ...de down with the glass plate pointing down and look at the glass plate from the side for any signs of moisture water ingress After each use the lamp should be thoroughly rinsed in clean fresh water Du...

Page 16: ...ARGING RE CHARGEABLE CELLS The lithium manganese re chargeable cells used in this lamp have been declared as gas and acid alkali sealed For this reason the electrolyte in the cells cannot escape and t...

Page 17: ...on a dry surface that is not sensitive Even gas tight lithium manganese cells may leak under certain conditions this leakage may cause damage to the surface the cell pack is placed on Note that a def...

Page 18: ...ONITORING DURING CHARGING The control module in the lamp monitors the temperature of the cell pack during charging If the temperature of the cell pack exceeds 60 C 140 F during charging the charge pro...

Page 19: ...e charger into the mains socket The charger is equipped with a standard euro 2 pin flat plug Other popular plug configurations are available and replace the euro plug simply by pulling it out and fitt...

Page 20: ...ry out a self test after which time the LEDs will illuminate Charger LEDs when charging NC or NMH re chargeable cells LED I Green Mains supply connected charger is functioning correctly Red Mains supp...

Page 21: ...Every time the lamp housing is opened latest after 6 months or 50 times use X Replace the O rings in the covers Every 12 months or earlier if damaged X Clean and dry external charging connections Befo...

Page 22: ...over and O ring 2 Return the lamp to the manufacturer for repair Lamp does not turn on 1 Cell pack is discharged 2 Bulb is defective 1 Charge the cell pack 2 Replace bulb Charging LED does not illumin...

Page 23: ...bags TRANSPORT BAG CHARGER Nylon bag offers protection whilst transporting the charger in diving gear bags CARABINER CLIPS For securing the lamp to a suitable point on the diving equipment CARABINER...

Page 24: ...for technical changes Issue 01 2011 24 Instructions for use Hartenberger High Tech UW Lamp nano compact Hartenberger Unterwassertechnische Ger te GmbH Rennebergstr 19 D 50939 K ln Germany Tel 49 221 4...

Reviews: