CARE AND MAINTENANCE
HOUSING
We recommend that from time to time the housing surface is impregnated with
silicone. The chance of calcium depositing on the surface of the lamp is
reduced and the scratch resistance properties of the housing surface are also
improved. (Action to be taken Interval By Owner)
Action to be taken
Interval
By Owner
Workshop
Examine wrist strap / hand line
for integrity/damage
Before each use
X
Examine the O rings and
sealing surface of the end
covers for damage,
contamination and/or
deterioration, clean and
lubricate as necessary
Every time the lamp
housing is opened
latest after 6 months
or 50 times use
X
Replace the O rings in the
covers
Every 12 months or
earlier if damaged
X
Clean and dry external charging
connections
Before each external
charge
X
Rinse under and around the
switch with fresh water while
moving the switch
After each dive
X
Impregnate the housing with
silicone grease
After several uses as
necessary
X
Replace the O rings under the
rear cover (charging
connections/pressure over
pressure indicator
Every 500 dives or
every 3-4 years at
the latest
X
Replace the O ring in the front
cover (glasses)
If damaged /
deteriorated or every
5 years at the latest
X
Replace the halogen bulb
Life expectancy
approx 100 hours
X
Replace cell pack
Life expectancy up to
500 operating hours
X
SERVICE LOG O RING / HALAOGEN BULB REPLACEMENT
O-Ring 48x3,0
Glass plate
O-Ring 40x3,0/48x1,6
front cover
O-Ring 40x3/48x1,6
rear cover
Halogen
bulb
Notes: