background image

 

©Hartenberger Unterwassertechnische Geräte GmbH   Rights reserved for technical changes.   Issue 01.2011

 

13 

 Instructions for use   Hartenberger   High-Tech-UW-Lamp   nano compact 

 

If the switch is pushed to the right (+) for longer (approx. 1 second), the lamp will 
turn on to the highest brightness stage (125%). 
If the switch is pushed for approx 1 second to the left, the lamp will switch off 
immediately. 

If the switched is pressed down for approx. 3 seconds, the LEDs will show the 
brightness currently set. 

One

 LED = 50%,  

two

 LED´s = 75%,  

three

 LED´s = 100%,  

four

 LED´s = 125% 

After another 3 seconds, the display then indicates the current cell pack capacity. 

When the lamp is turned off, the LED display will also switch off. Sliding the 
switch to the left will then activate the LED display and shows the current cell 
pack capacity, this remains visible for approx 3 seconds. 

SOS WARNING / DISTRESS SIGNAL 

The electronics have the facility to transmit an SOS signal in Morse alphabet  
(2 x short, 3 x long, 3 x short). 
If the switched is pressed for an extended time (approx. 5 seconds) to the right 
(+), this function is activated and the lamp begins to blink SOS. 
Pressing the switch to the left (-) for approx. 1 seconds stops the SOS signal. 
The time that the lamp will generate the SOS signal is approx. 3 times longer than 
the continuous burning time of the halogen bulb fitted. When the cell pack is 
almost fully discharged, the SOS signal will fade and dim. Only use the SOS 
function in a distress or emergency situation. If the lamp fades, turn the 
signal off and only turn it back on when help is in sight. 

EMERGENCY LIGHTING (AUTOMATIC) 

The lamp’s electronics will automatically sense a defective bulb and will 
automatically turn on all the LEDs. This serves as an emergency source of light 
for reading instrumentation or for orientation in a very dark environment. To turn 
the emergency lighting off, push the switch to the left (-). Pushing the switch to 
the right (+) will reactivate the emergency light. 

EMERGENCY LIGHTING (MANUAL) 

The emergency light (all 4 LEDs are illuminated continuously) may be activated 
manually. Push the switch to the left for approx. 5 seconds. This emergency light 
will last longer than the normal bulb burning time and will provide you with an 
emergency source of light for reading instrumentation or for orientation in a very 
dark environment. To turn the emergency lighting off, push the switch to the  
left (-). The emergency light function will not activate after the lamp has turned off 
automatically in the discharge protection mode. 

OVER-VOLTAGE / DIMMER 

The HLX bulbs which we use have a much greater efficiency than standard 
halogen bulbs. Using a 6 cell power pack, we have a power supply of 7,2 volts. 
This allows the 6v bulb to be operated continuusly with an over-voltage of approx. 
6,8 volts. The electronics switch the bulb on slowly thus preventing the coil in the 
bulb from burning out. The resulting increase in brightness is approx. 30% more 
than the stated power. The micro controller can accurately monitor the energy 
dissipation to the bulb and ensures a continuous colour temperature over the 
entire discharge process and operation. The life expectancy of the bulb of approx. 
100 hours is not reduced. Using the lamp at reduced power settings saves energy 
and extends the burning time in a single charge cycle. Permanently operating the 
lamp at reduced power settings will however produce a grey coating on the bulb’s 

Summary of Contents for Nano compact

Page 1: ...Instruction for use Hartenberger Underwater Hand Lamp Hartenberger nano compact pressure indicator LED power control unlock lock OFF 25 LED 125 25 SOS 1 sec 0 5 sec 5 sec nano compact...

Page 2: ...ER 9 POWER PACK 11 PREPARATION FOR USE 11 USING THE UNDERWATER LAMP 12 TRANSPORT 15 STORAGE 16 CHARGING 16 CHARGER OFF SHORE I 6 19 CHARGER OFF SHORE II 20 CARE AND MAINTENANCE 21 FAULT DIAGNOSIS 22 S...

Page 3: ...rantee Any unauthorised work on the lamp i e the removal or tightening of screws or the removal of the guarantee seals will make the guarantee invalid Warning The manufacturer s warranty expires if th...

Page 4: ...TOR COVER The standard front cover is equipped with a spot reflector for use with halogen bulbs Flood reflectors and or chemically matt coated front glasses are available as options C FRONT HOUSING CO...

Page 5: ...cts are colour coded red right contact and blue left contact N MAGENTIC SWITCH TRANSPORT LOCK The magnetic switch is used for all the control functions of the lamp and the electronics To lock the lamp...

Page 6: ...bulb during transport V CELL PACK The cell pack is plugged in to the power pack and can be removed replaced in seconds The cell pack consists of a Lithium Manganese LiMn cell block a micro processor e...

Page 7: ...WEIGHT PRESSURE RATING Length Diameter weight on land weight in water Resistance to water Pressure 150mm x 59mm 6 x 2 0 6kg 1lb 5oz 0 2kg 7oz 100m 330 ft FRONT GLASS PLATE The nano compact lamps have...

Page 8: ...nt tool should be used for the removal of the O ring i e a wooden tooth pick Before the components are refitted it is recommended that a thin coating of silicone grease is applied as lubrication It is...

Page 9: ...rtments adjacent to the bulb socket Bulbs are safely stowed in these compartments and the plastic cover prevents them from inadvertently falling out This cover must be turned open to access the bulb s...

Page 10: ...O rings and its groove should be thoroughly cleaned Should the sealing surfaces and or components be damaged then all damaged parts should be replaced If the O ring 40 x 3 0 50 hardness and 48 x 1 6 5...

Page 11: ...t the 3 plugs on the rear housing cover are guided into the sockets carefully The plug arrangement prevents incorrect connection Push the cell pack fully down on to the pins without damaging distortin...

Page 12: ...22 TRANSPORT LOCK Release the transport lock immediately before use To unlock the switch push it from the transport lock position lock outwards unlock the switch must physically click into the unlock...

Page 13: ...s electronics will automatically sense a defective bulb and will automatically turn on all the LEDs This serves as an emergency source of light for reading instrumentation or for orientation in a very...

Page 14: ...ssary the lamp if possible after a short pause can be reactivated and will automatically turn on at 25 power setting The cells are almost certainly damaged should this mode of operation be selected If...

Page 15: ...de down with the glass plate pointing down and look at the glass plate from the side for any signs of moisture water ingress After each use the lamp should be thoroughly rinsed in clean fresh water Du...

Page 16: ...ARGING RE CHARGEABLE CELLS The lithium manganese re chargeable cells used in this lamp have been declared as gas and acid alkali sealed For this reason the electrolyte in the cells cannot escape and t...

Page 17: ...on a dry surface that is not sensitive Even gas tight lithium manganese cells may leak under certain conditions this leakage may cause damage to the surface the cell pack is placed on Note that a def...

Page 18: ...ONITORING DURING CHARGING The control module in the lamp monitors the temperature of the cell pack during charging If the temperature of the cell pack exceeds 60 C 140 F during charging the charge pro...

Page 19: ...e charger into the mains socket The charger is equipped with a standard euro 2 pin flat plug Other popular plug configurations are available and replace the euro plug simply by pulling it out and fitt...

Page 20: ...ry out a self test after which time the LEDs will illuminate Charger LEDs when charging NC or NMH re chargeable cells LED I Green Mains supply connected charger is functioning correctly Red Mains supp...

Page 21: ...Every time the lamp housing is opened latest after 6 months or 50 times use X Replace the O rings in the covers Every 12 months or earlier if damaged X Clean and dry external charging connections Befo...

Page 22: ...over and O ring 2 Return the lamp to the manufacturer for repair Lamp does not turn on 1 Cell pack is discharged 2 Bulb is defective 1 Charge the cell pack 2 Replace bulb Charging LED does not illumin...

Page 23: ...bags TRANSPORT BAG CHARGER Nylon bag offers protection whilst transporting the charger in diving gear bags CARABINER CLIPS For securing the lamp to a suitable point on the diving equipment CARABINER...

Page 24: ...for technical changes Issue 01 2011 24 Instructions for use Hartenberger High Tech UW Lamp nano compact Hartenberger Unterwassertechnische Ger te GmbH Rennebergstr 19 D 50939 K ln Germany Tel 49 221 4...

Reviews: