Gas Fired Boiler
9
Harsco Industrial, Patterson-Kelley Technical Service 1.877.728.5351
2.3 Training
Proper training is the best protection against accidents. It is
essential
to read, understand, and follow the recommendations of
this manual before installing, operating, or servicing this
equipment. Failure to do so could
result in fire or explosion and
serious injury, death, and/or property damage.
Operating and service personnel must be thoroughly familiar with
the basic construction of the SC-2000,
SC-3000
and
SC-4000
boilers, the use and locations
of the controls, the operation of the
boilers, adjustment of their various mechanisms, and all applicable
safety precautions. If any of the provisions of this manual are not
fully and completely understood, contact Harsco Industrial,
Patterson-Kelley Technical Service at
570.476.7261
or toll free at
877.728.5351.
2.4 Hazard Warnings
2.4.1 Electrical Hazards
Shock Hazard!
Properly lockout/tagout the electrical
service and all other energy sources before working on
or near the boiler.
Shock Hazard!
Do not spray water directly on this
boiler or any electrical components.
Electrical Hazard!
Do not alter wiring connections.
2.4.2 Crush Hazards
Lifting Hazards!
Use properly rated lifting equipment
to lift and position the boiler. The load is unbalanced.
Test the balance before lifting off the floor. Do not
allow personnel beneath the lifted load. Refer to the
approximate weights in the table.
2.4.3 Bump Hazard from Overhead Ductwork and Piping
Injury Hazard!
Install components with adequate
vertical clearance.
2.4.4 Pressure Hazards
Pressure Hazard!
Hot fluids. Install isolation valves on boiler water inlet and outlet. Make sure
isolation valves are closed before servicing boiler.
Pressure Hazard!
Hot fluids. Annually test safety relief valve(s) for proper operation. Do not operate
boiler with faulty relief valve(s).
Boiler Model
Weight in Pounds
SC-2000 1,450
lbs
SC-3000 1,850
lbs
SC-4000 1,900
lbs
N
OTICE
!
The safety labels shown below are
affixed to your boiler. Although the
labels are of high quality, they may
become dislodged or unreadable
over time. Contact Harsco
Industrial, Patterson-Kelley at
570.476.7261 or toll-free at
877.728.5351 for replacements.
Gas may lose its odor. Proper gas
sensing equipment and procedures
should be used for leak checks.
Failure to detect gas leaks could
result in injury or death.