Chapter 4
Connector Pinouts
40
175-100423-00
How to Wire Your NEXIO Weidm
ü
ller Male Connectors
1
Using a wire stripper, remove no more than 5/16”
of the wire installation from each of the required
wires. Refer to
Figure 4-3
.
2
Make sure the installation is clean-cut with no
frayed or ragged edges, trim if necessary.
3
Retwist strands by hand, if necessary, to restore
the natural lay and tightness of the strands.
4
To wire the Weidmüller GPI
Connector
, refer to
Figure 4-1
on page 38 or
Figure 4-2
on
page 39 and
Figure 4-5
:
a
Insert a flat blade 3/32” screwdriver into the
Weidmüller connector.
b
Insert wire into the connector.
c
Remove the flat blade screwdriver.
d
Repeat
step a
thru
step c
for each additional
wire.
Figure 4-3
Stripped wire installation length
Figure 4-4
Weidmüller pin callout
Figure 4-5
How to insert wire into Weidmüller
connector