HS-3030 Programming Manual
17
Annunciators have the
following unique controls
for programming (see
Figure 10
).
The
LCD
check box is
located immediately left of
the buttons. It indicates
whether or not the
annunciator has an alpha-
numeric LCD. This setting
is used by NP only to
determine if the
Message
Receive
check box should
be shown for the
annunciator in the Relate
Window. This value is not
sent to the annunciator.
LED Count
is located
directly below the LCD
check box. This defines the number of LED zones the annunciator will be using. A count of zero
will disable the Hot LEDs and Common LED.
Hot LED
is located directly below the LED Count drop down. This value defines the first of four
LED zones the annunciator will use for internal functions. Any of the zones can be chosen with the
requirement that there are four consecutive zones available. Entering a zone of 0 will disable the
hot key zones. These will reflect the current status of the annunciator and the panel(s) it sends
commands to.
Figure 10: Annunciator Panel Window