8c. Remove protection rubber
•
Remove the protection from the lower and upper part of the
casing around the pipe.
8a. Remove filling material
•
Carefully remove the filling material which is placed in the
space around the rear connection.
•
Check thouroughly that no filling material is left. Caution; left
filling material causes fire hazardous.
8d. Remove packaging foil
•
Remove the packaging foil.
8b. Positioning sliding part for connecting pipe
•
Push the sliding part over the connecting pipe of the wall plate.
• Push it up to the wall plate.
Installing duct material on rear outlet
Rear outlet
Rear outlet
Rear outlet
Rear outlet
8e. Fix connector
•
Fix the connector on the lower part of the pipe (screwdriver).
9. Air supply
•
When using a room-independent air supply system: leave the
cover strip in place.
•
If there is no room-independent air supply system: remove the
cover strip from the base (crosshead screwdriver).
Rear outlet
Top and rear outlet
38
39