eXLhoist Configuration Software
EIO0000001505 12/2014
195
Restriction Due To Remote Device
This tab is automatically modified according to the selected/connected Remote Device:
Generic Description
The main use of this tab is to configure the association between the buttons and the relays.
To associate a button to a relay:
As long as the button is pressed, the associated relay(s) is(are) activated.
The cells in gray cannot be assigned.
4 relays maximum can be associated with the motion buttons (1…6+7).
Selector Configuration
The Selector configuration consists in:
In SINGLE configuration:
The selector is used to manage relays that are able to switch for example between 2 hooks or 2
trolleys
Reference
Disable relay column
Disable limit switches
group
Disable buttons rows
ZART8L
13...18
Yes
12…15+7
ZART8D
-
-
12…15+7
ZART12D
-
-
-
Step
Action
1
Click a cell to associate a button to a relay.
Result:
The empty cell has now an associated symbol
2
To be more explicit, you can click in the
Name
text zone of a button to modify it (24 characters
maximum).
Step
Action
1
Check the
Selector Enable
checkbox.
2
Select in the
N
°
Button
listbox the button to be used as selector.
For ZART8: it is possible to assign button 10...11 to the selector.
For ZART12: it is possible to assign button 10...15 to the selector.
3
Select 2 or 3 in the
Nb Position
combobox.
4
Click a cell to associate a relay to a selector position.
Summary of Contents for eXLhoist
Page 12: ...12 EIO0000001505 12 2014...
Page 34: ...Wireless Remote Control System 34 EIO0000001505 12 2014...
Page 52: ...52 EIO0000001505 12 2014...
Page 146: ...Using The Wireless Remote Control System 146 EIO0000001505 12 2014...
Page 200: ...eXLhoist Configuration Software 200 EIO0000001505 12 2014...
Page 213: ...EIO0000001505 12 2014 213 Harmony eXLhoist EIO0000001505 04 2014 Appendices...
Page 214: ...214 EIO0000001505 12 2014...