EIO0000001505 12/2014
41
Power Supply
Protective Earth Ground
The PE must be connected to the machine to protect against maloperation due to earth faults (IEC
60204-1, Protection against maloperation due to earth faults).
The PE must be connected to the machine ground (IEC 60204-1, protection against electric
shock). If not then the Base Station inputs voltage (IN_COM, S2_S3, IN0…IN18) could increase
to a dangerous voltage because of the possible static electricity induced by the machine motions.
Maximum operating rate
-
2 Hz
Weight
-
1340 kg
(2954 lb.)
1360 kg
(3644 lb.)
1430 kg
(3831 lb.)
1450 kg
(3885 lb.)
Specifications
Details
Value
ZARB12H
ZARB12W
ZARB18H
ZARB18W
NOTICE
INOPERABLE EQUIPMENT
The ZARB•H Base Station must be powered with a voltage:
From 24 Vac -15% to 48 Vac +10% with frequency of 50 Hz -6%/+4% and frequency of 60 Hz
-6%/+4%.
From 24 Vdc -15% to 48 Vdc +20%.
The ZARB•W Base Station must be powered with a voltage:
From 24 Vac -15% to 240 Vac +10% with frequency of 50 Hz -6%/+4% and frequency of
60 Hz -6%/+4%.
From 24 Vdc -15% to 240 Vdc +20%.
Failure to follow these instructions can result in equipment damage.
WARNING
UNINTENDED EQUIPMENT OPERATION
Connect the Base Station protective earth ground connection to the machine ground.
Failure to follow these instructions can result in death, serious injury, or equipment
damage.
Summary of Contents for eXLhoist
Page 12: ...12 EIO0000001505 12 2014...
Page 34: ...Wireless Remote Control System 34 EIO0000001505 12 2014...
Page 52: ...52 EIO0000001505 12 2014...
Page 146: ...Using The Wireless Remote Control System 146 EIO0000001505 12 2014...
Page 200: ...eXLhoist Configuration Software 200 EIO0000001505 12 2014...
Page 213: ...EIO0000001505 12 2014 213 Harmony eXLhoist EIO0000001505 04 2014 Appendices...
Page 214: ...214 EIO0000001505 12 2014...