6. Storage overview
To store the linear actuator temporarily or stop using it for a long time, take measures based on the next page.
After storing it for a long time, perform a trial run (refer to Trial run in section 5) to check the operation state.
6-1 Storage location
◆
No dust, dirt, or moisture
◆
No toxic gas or liquid
◆
Storage temperature: -20
°
C to 50
°
C
◆
Storage humidity: 20 to 80%RH (no condensation)
◆
Vibration: 24.5m/s
2
(2.5G) or less
6-2
Rust proof measure
◆
Before storing, provide rust-proof treatment lightly on the side of the output rod (refer to 3. Structure
and part names) with a waste with rust-proof oil or grease.
◆
To prevent rust in the bearing or feed screws, perform back-and-forth movement of the linear
actuator in the range of ±25mm several times every 3 months.
◆
As a measure against moisture, seal the linear actuator with vinyl sheet with absorbent such as
silica gel.
6-3 Storage orientation
◆
The storage orientation is horizontal. Be careful not to crush lead wires.
This manual described how to handle the linear actuator.
If any accident occurs, check the model and number on the nameplate, and contact your distributor or one of our
sales offices. In case of failure, report the details as much as possible.