54
Exterior Projection 1000 User Manual
Connections
Power cable entry ................................................................................................ IP66 cable gland
Power connection .............................................................. 1.8 m (5.9 ft.) cable tail with bare ends
Power cable type ....................................................... EU models: H07RN-F 450/700 V, Ø 10 mm
US models: SJTW 14AWG, 300 V, Ø 9.3 mm (0.37 in.)
Data cable entry .................................................................................................. IP66 cable gland
Data connection ........................ 1.8 m (5.9 ft.) combined input + output cable tail with bare ends
Electrical
AC power ........................................................................... 100-120/200-277 V nominal, 50/60 Hz
Power supply ........................................................................ Auto-ranging electronic switch-mode
Typical half-cycle RMS inrush current .................................................................................. 15.5 A
Surge protection ...................................................................................................................... 4 kV
Idle power (zero intensity, no effects applied) ........................................................................ 75 W
Typical Power and Current
120 V, 60 Hz ................................................................................................ 645 W, 5.5 A, PF 0.98
230 V, 50 Hz ................................................................................................ 635 W, 2.9 A, PF 0.95
277 V, 60 Hz ................................................................................................ 635 W, 2.6 A, PF 0.90
Figures are typical, not maximum. Measurements made at nominal voltage with all LEDs at full
intensity. Allow for a deviation of +/- 10%. PF = Power Factor.
Thermal
Cooling ........................................................................................... Convection, internal forced air
Total heat dissipation (calculated) ............................................................................. 2350 BTU/hr.
Maximum surface temperature ................................................................................ 85° C (185° F)
Maximum ambient temperature (Ta max.) ............................................................. 45° C (113° F)*
Minimum ambient temperature (Ta min.) ............................................................. -30° C (-22° F)**
*Above this temperature the fixture regulates output to protect from overheating.
**For instant wake-up with no warm-up mode, leave power applied constantly in ambient
temperatures below 0° C (32° F).
Approvals
Global CB Certification/IECEE ........................................................ IEC 60598-2-5 (IEC 60598-1)
EU safety .............................. EN 60598-2-1, EN 60598-2-5 (EN 60598-1), EN 62471, EN 62493
EU EMC ................................. EN 55015, EN 55032, EN 55103-2, EN 61000-3-2, EN 61000-3-3,
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61547
US safety ................................................................................................................. ANSI/UL 1598
US EMC .................................................................................................... CFR 47 Part 15 Class A
Canadian EMC .................................................................... ICES-003 Class A, NMB 3-5 Class A
Australia/NZ ............................................................................................................................ RCM
Included Items
Silica gel desiccant bag ........................................................................................... P/N 37220000
Two gobo retaining springs, extra length, for use with non-textured gobos
Accessories
Glare Shield, Exterior Projection 1000 .................................................................... P/N 91611768
‘Line it Up’ Projection Setup Gobo for Exterior Projection 1000 ............................. P/N 91616075
Gobo Ring, Outer Diameter 30 mm, Set of 10 ............................................... P/N MAR-91611851
Protection Spring for Exterior Projection 1000 (use during transport) .................... P/N 91611097
Summary of Contents for Martin Exterior Projection 1000
Page 56: ...Notes...
Page 57: ...Notes...
Page 58: ...Notes...
Page 59: ...Notes...
Page 60: ...www martin com...