background image

Safety Information

 5

P R O T E C T I O N   F R O M   E L E C T R I C   S H O C K

• Do not remove any cover from the fixture except as described under “Service and maintenance” on 

page 14.

• To ensure that the fixture’s IP65 rating has not been affected by removal of a cover, test that the fixture is 

correctly sealed after reassembly using a vacuum tester as described in this manual.

• Disconnect the fixture from AC mains power before servicing it and when it is not in use. 

• Ensure that the fixture is electrically connected to ground (earth).

• Use only a source of AC mains power that complies with local building and electrical codes and has both 

overload and ground-fault (earth-fault) protection.

• Consult a qualified electrician to ensure correct branch circuit conductor.

• The fixture accepts AC mains power at 100-240 VAC (nominal), 50/60 Hz. Do not connect the fixture to 

mains power that is not within this range.

• Do not connect devices to power in a chain or circuit that will exceed the electrical ratings of any cable or 

connector used in the circuit.

• Power input cables must be rated 16 A minimum, 12 AWG or 1.5 mm

2

 minimum conductor size and 

heat-resistant to 90° C (194° F) minimum. Cables must have three conductors and an outer cable 
diameter of 6 - 12 mm (0.24 - 0.47 in.). In North America the cable must be UL/CSA-recognized, hard 
usage, type SJT, SJOOW or better. In the EU, the cable must be type HO5VV-F, H07RN-F or better.

• Connect only a Neutrik powerCON TRUE1 NAC3FX-W (TOP) type cable connector to the power input 

socket.

• If operating outdoors, in wet conditions or in conditions where condensation may appear, arrange cables 

so that they arrive from below connectors. Create a ‘drip loop’ if necessary, but do not allow heavy cable 
runs or loops of cable to hang from connectors.

• Before using the fixture, check that all power distribution equipment, connectors and cables are in perfect 

condition and rated for the current requirements of all connected devices.

• Isolate the fixture from power immediately if the power plug or any seal, cover, cable, or other component 

is damaged, defective, deformed or showing signs of overheating. Do not reapply power until repairs have 
been completed.

• The ERA 500 Hybrid IP contains components that are accessible and live at high voltage while the fixture 

is connected to power and that remain under tension for up to five minutes after power is disconnected. 
Wait for at least five minutes after disconnecting from power before opening any of the fixture’s covers (if 
the fixture has been in use, allow to cool for 60 minutes before handling).

• Refer any service operation not described in this manual or in the ERA 500 Hybrid IP User Guide to 

Martin Service or an authorized Martin Service partner.

L A M P   S A F E T Y

• Prolonged exposure to an unshielded discharge lamp can cause eye and skin burns. Do not stare directly 

into the light output. Never look at an exposed lamp while it is lit. Do not operate the fixture with missing or 
damaged covers, shields, lenses or ultraviolet screens.

• A hot discharge lamp is under pressure and can explode without warning. Allow the fixture to cool for at 

least 60 minutes and protect yourself with safety glasses and gloves before handling a lamp or carrying 
out any service work inside the fixture.

• Replace the lamp immediately if it becomes visually deformed, damaged or in any way defective

• Monitor hours of lamp use and lamp intensity and replace the lamp when it reaches the limit of its service 

life as specified in this product’s specifications or by the lamp manufacturer.

• Install only a lamp that is specifically approved by Martin for this product.

• If the clear bulb of a discharge lamp is broken, it releases a small quantity of mercury and other toxic 

gases. Have suitable mercury vapor protection masks ready when servicing the fixture and use them if 
there is any risk that potentially harmful vapors may be inhaled. If a discharge lamp breaks in a confined 
area, evacuate the area and ventilate it thoroughly. If there is a possibility that the lamp has exploded or 
the bulb has broken inside the fixture, move the fixture outdoors or make it safe by using an air extractor 
system that will remove any potentially harmful vapor, then put on a mercury vapor protection mask and 
safety gloves before opening the fixture. 

• Wear nitrile gloves when handling a broken discharge lamp. Treat broken or used discharge lamps as 

hazardous waste and send to a specialist for disposal.

• The wires that supply power to the lamp carry high voltage. Wear insulating safety gloves and do not 

touch the lamp wiring or lamp wiring connectors when carrying out lamp adjustment.

Summary of Contents for Martin ERA 500 Hybrid IP

Page 1: ...ERA 500 Hybrid IP Safety and Installation Manual...

Page 2: ...for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Marti...

Page 3: ...9 AC power 11 Power input 11 Data links 13 DMX and RDM 13 Service and maintenance 14 Managing humidity 14 Pressure relief valves 15 Dehumidifying the fixture 15 Vacuum testing 16 Cleaning 17 Lubricati...

Page 4: ...RA 500 Hybrid IP check the Martin website and make sure that you have the latest user documentation for the fixture Document revisions are indicated at the bottom of page 2 This product is for profess...

Page 5: ...hat are accessible and live at high voltage while the fixture is connected to power and that remain under tension for up to five minutes after power is disconnected Wait for at least five minutes afte...

Page 6: ...8 under worst case conditions At a distance of less than 19 2 m 63 ft from the fixture the light output can potentially cause eye or skin injury before an exposed person s natural aversion responses b...

Page 7: ...8 2 17 Section 17 6 6 or BGV C1 DGUV 17 and must be capable of bearing a static suspended load at least six times or more if required by locally applicable regulations the weight that it secures Elimi...

Page 8: ...for complex projections and mid air effects For the latest firmware updates documentation and other information about this and all Martin products please visit the Martin website at http www martin co...

Page 9: ...or shade the head so that the front lens will not be exposed to sunlight or another strong light source from any angle even for a few seconds See Figure 1 The ERA 500 Hybrid IP s lens can focus the s...

Page 10: ...rom a stable platform hang the fixture on the truss with the front facing towards the area to be illuminated Tighten the rigging clamps 5 See Figure 5 Install a safety cable that is approved as a safe...

Page 11: ...urce The power cable can be hard wired to a building installation circuit or fitted with a mains plug cord cap to allow connection to local AC mains power outlets If you install a mains plug on the po...

Page 12: ...h clicks and that the connector is locked into the socket 3 If operating outdoors in wet conditions or in conditions where condensation may appear ensure that all cables arrive from below connectors C...

Page 13: ...ot overload the DMX data link You can connect up to a maximum of 32 devices on a serial DMX link Install a DMX termination plug on the last fixture on the link Connecting to data via DMX cable To conn...

Page 14: ...rface see Related Items on page 26 and the Martin Companion software suite available for download free of charge from the Martin website at www martin com All other service operations on the ERA 500 H...

Page 15: ...ronment where airborne dust or dirt is present we recommend that you replace the valves with their rubber seals each time you replace the lamp If heavy dust or dirt is present and the fixture is power...

Page 16: ...ent You will need the following items Vacuum tester you can obtain a suitable tester from Martin see Related Items on page 26 M12 x 1 5 adapter available from Martin see Related Items on page 26 to co...

Page 17: ...head by wiping gently with a soft clean lint free cloth moistened with a weak detergent solution Do not rub the surface hard lift particles off with a soft repeated press Dry with a soft clean lint f...

Page 18: ...create a safety hazard Replacement lamps are available from Martin see Spare parts on page 26 The lamp bulb and reflector must be perfectly clean when you install the lamp Do not touch them with your...

Page 19: ...wed on the left hand side of the lamp compartment just above the horizontal lamp adjustment screw Do not confuse the two screws the lamp slider locking screw is smaller than the horizontal lamp adjust...

Page 20: ...sealed to its original IP65 level carry out a vacuum test as described in Dehumidifying the fixture on page 15 19 Each time you install a new lamp reset the lamp lifetime counter in the fixture s cont...

Page 21: ...ear cover fan is disconnected 7 See Figure 15 Turn the two Torx 20 lamp adjustment screws A for vertical adjustment and B for horizontal adjustment until you obtain the most even projection 8 Shut dow...

Page 22: ...fore applying power to the fixture Read the safety information section of this manual starting on page 4 Read Connecting to power on page 11 Check that the installation is safe and secure Check that t...

Page 23: ...ERA 500 Hybrid IP on the data link Incorrect addressing of fixtures Check fixture address and protocol settings One of the fixtures is defective and is disturbing data transmission on the link Unplug...

Page 24: ...Motorized Pan 540 coarse fine control and speed Tilt 260 coarse fine control and speed Control and Programming Control options DMX RDM 16 bit control Dimming pan and tilt Setting and addressing Contr...

Page 25: ...perature steady state at Ta 40 C 60 C 140 F Maximum ambient temperature Ta max 40 C 104 F Minimum ambient temperature Ta min 20 C 4 F Maximum total heat dissipation calculated 10 2120 BTU hr Allow for...

Page 26: ...n Companion software suite incl firmware uploader Free download from www martin com Martin Companion Cable USB DMX hardware interface P N 91616091 Martin RDM 5 5 Splitter P N 90758150 Martin Vacuum Te...

Page 27: ...nformity for this product The Declaration of Conformity is available for download from the ERA 500 Hybrid IP area of the Martin website at www martin com Canadian Interference Causing Equipment Regula...

Page 28: ...www martin com...

Reviews: