AC power
11
AC power
Warning! Read “Safety Information” on page 4 before connecting the fixture to AC mains power.
For protection from electric shock, the fixture must be electrically connected to ground (earth). The
AC mains power distribution circuit must be equipped with a fuse or circuit breaker and ground-fault
(earth-fault) protection.
Power input
Important! Connect the ERA 500 Hybrid IP directly to AC power. Do not connect it to a dimmer
system; doing so may damage the fixture.
The ERA 500 Hybrid IP features an auto-sensing switch-mode power supply that automatically adapts to
AC mains power at 100-240 VAC (nominal), 50/60 Hz. Do not connect the fixture to power that is not within
this range.
The ERA 500 Hybrid IP requires a power input cable with a Neutrik powerCON TRUE1 NAC3FX-W (TOP)
IP65-rated female cable connector for AC mains power input. The cable must meet the requirements listed
under “Protection from electric shock” on page 5. Martin can supply suitable cables with IP65-rated female
Neutrik input connectors 1.5 m (4.9 ft.) or 5 m (16.4 ft.) long. Alternatively, Martin can supply loose
IP65-rated female Neutrik input connectors (see “Accessories” on page 34).
Connection to an AC mains power source
The power cable can be hard-wired to a building installation circuit or fitted with a mains plug (cord cap) to
allow connection to local AC mains power outlets.
If you install a mains plug on the power cable, install a grounding-type (earthed) plug rated minimum 16 A,
250 V (example rating: EN 60309-2 CEE 2P+E 16 A/250 VAC), following the plug manufacturer’s
instructions. Table 1 shows some possible mains power pin identification schemes; if the pins are not clearly
identified, or if you have any doubts about proper installation, consult a qualified electrician.
If you need to install a Neutrik powerCON TRUE1 connector on a power cable, follow the instructions on the
Neutrik website at www.neutrik.com.
Connecting to power
Warning! The ERA 500 Hybrid IP does not have a power On/Off switch. As soon as you connect an
energized power input cable to the fixture or apply power to a power input cable that has already
been connected, the fixture will power up: check that there is no safety risk from head movement or
intense light output.
To apply power to the ERA 500 Hybrid IP:
1. Check that the base is held securely. Be prepared for the fixture to light up and the head to move
suddenly when power is applied.
Wire Color (US)
Wire Color (EU)
Pin
Symbol
Screw (US)
black
brown
live
L
yellow or brass
white
blue
neutral
N
silver
green
yellow/green
ground (earth)
or
green
Table 1: Cord cap (mains plug) connections