Introduction
6
NI-2100/3100/4100 - Hardware Reference Guide
Timekeeper
The Controllers use a combination lithium battery and clock crystal package called a
Timekeeper
. Only one
Timekeeper
unit is
installed within a given NI controller. The battery can be expected to have up to 3 years of usable life under very adverse conditions.
Actual life is appreciably longer under normal operating conditions.
This calculation is based on storing the unit without power in 50° C (120° F) temperature until battery levels are no longer
acceptable.
The part number for a replacement battery is
57-0032
.
CAUTION:
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO
THE INSTRUCTIONS
NI-2100
The NI-2100 (
FG2105-04
) is ideal for control and automation of medium-sized rooms and multi-room applications. The NI-2100
has 64MB of onboard RAM and is Device Discovery enabled to simplify programming by standardizing device and function
definitions, default touch panel button assignments, and control and feedback methods.
NI Controllers - Features (Cont.)
NI-4100 NetLinx Integrated Controllers
Name / FG#
Features
NI-4100 Controller
(FG2105-06)
• 7 Configurable RS-232 / RS-422 / RS-485 Serial ports
• 8 Relays
• 8 IR / Serial ports
• 8 Digital I/O ports
• 3 Communication Networks: AxLink, ICSNet and Ethernet (TCP/IP)
• 4 NetLinx Control Card Expansion slots that support all NXC control cards
• 404 MIPS processor speed
• 64 MB RAM
• 512 MB CompactFlash (upgradeable to 4 GB)
• 1 MB Non-Volatile Memory
• AMX Device Discovery enabled
• JITC Compliant
NI-4100/256 Controller
(FG2105-26)
Same as the NI-4100 (above), but with 256 MB RAM.
Note: The NI-4100/256 is not JITC Compliant.
FIG. 1
NI-2100
LINK/ACT LED
STATUS LED
INPUT LED
OUTPUT LED
RS-232/422/485 Status LEDs
RELAY Status LEDs
IR/SERIAL Status LEDs
I/O Status LEDs
front
rear
RS-232/422/485 (Ports 1-3)
ICSNet/ICSHub Ports
(provided by optional
ICSNet daughter card)
Relays (Port 4)
I/O (Port 9)
IR/Serial (Ports 5-8)
PROGRAM Port
CONFIGURATION DIP Switch
ID Pushbutton
ETHERNET
10/100 Port
AxLink Port
12 VDC PWR Connector