Harman AMX NI-2100 Hardware Reference Manual Download Page 14

Installation and Upgrading

14

NI-2100/3100/4100 - Hardware Reference Guide

Installation and Upgrading

Installing NetLinx Control Cards (NI-4100 Only)

You can install NetLinx Cards into the front card slots on the NI-4100. The cards mount horizontally through the card slot openings 

on the front of the enclosure.
1.

Discharge the static electricity from your body by touching a grounded object. 

2.

Remove the three screws by turning them in a counter-clockwise direction and then remove the faceplate (FIG. 4).    

3.

Align the edges of the card with the internal guide slots and gently slide the card all the way into the slot. 

4.

Carefully apply a small amount of force to insert the cards into their respective connectors. If the cards have LEDs on them, 

those LEDs will initiate a lighting sequence to indicate they are receiving power and are communicating with the Controller. 

5.

Re-align the faceplate and secure it to the chassis by inserting the three screws by turning them in a clockwise direction and 

securing the front plate to the Integrated Controller.

6.

Install all rear connectors and apply power.

NOTE: 

If the cards do not appear in the NetLinx Studio’s Workspace window for the selected Master System number: give the system 

time to detect the inserted cards (and refresh the system) and/or cycle power to the unit.

Setting the NetLinx Control Card Addresses (NI-4100 Only)

The 8-position CardFrame Number DIP switch (located on the rear of the NI-4100) sets the starting address (the device number in 

the D:P:S specification) for the Control Cards installed in the CardFrame. The address range is 1-3064. 



The factory default CardFrame DIP switch value = 

0

 (all CardFrame DIP switches in the OFF position).



The formula for setting the starting address is:

(DIP switch address x 12) + Card slot Number (1-12) = Card address

For example:



DIP switch setting, 00010101: (0 + 0 + 0 + 96 + 0 + 384 + 1536) + SLOT # (ex:1) = 2017. 



A card in slot number 1 would be device address 2017.

1.

Set the CardFrame Number DIP switch based on the information listed in the table below.

2.

Cycle power to the unit for approximately 5 seconds so the unit can read the new device number settings.

Device:Port:System (D:P:S)

A device is any hardware component that can be connected to an AxLink or ICSNet bus. Each device must be assigned a unique 

number to locate that device on the bus. The NetLinx programming language allows numbers in the range 1-32,767 for ICSNet 

(255 for AxLink). 

NOTE: 

Only the Device value can be set through the DIP switch settings mentioned above.

NetLinx requires a Device:Port:System (D:P:S) specification. This D:P:S triplet can be expressed as a series of constants, variables 

separated by colons, or a DEV structure. For example:

STRUCTURE DEV

{

INTEGER Number  // Device number

INTEGER Port    // Port on device

INTEGER System  // System the device belongs to

}

FIG. 4  

NI-4100 front faceplate

Position

1

2

3

4

5

6

7

8

Value

12

24

48

96

192

384

768

1536

Thumbscrews

NXC Card Slot faceplate

Summary of Contents for AMX NI-2100

Page 1: ...HARDWARE REFERENCE GUIDE NETLINX INTEGRATED CONTROLLERS NI 2100 NI 3100 NI 4100...

Page 2: ...nd the point where they exit from the apparatus 11 ONLY USE attachments accessories specified by the manufacturer 12 USE ONLY with a cart stand tripod bracket or table specified by the manufacturer or...

Page 3: ...allation of Compact Flash Upgrades 16 Closing and Securing the Outer Housing 17 Installing Into An Equipment Rack 17 Rack Mount Safety Instructions 17 Connections and Wiring 19 Setting the Configurati...

Page 4: ...Hub OUT Port Connections and Wiring 24 Relay Port Connections and Wiring 25 Relay Connections 25 Input Output I O Port Connections and Wiring 25 IR Serial Port Connections and Wiring 26 NetLinx Contro...

Page 5: ...easier by automatically identifying and communicating with devices which support this beaconing technology Features NI Controllers Features NI 2100 NetLinx Integrated Controllers Name FG Features NI...

Page 6: ...standardizing device and function definitions default touch panel button assignments and control and feedback methods NI Controllers Features Cont NI 4100 NetLinx Integrated Controllers Name FG Featur...

Page 7: ...ial channels 1 4 are transmitting control data on Ports 5 8 The LED indicator for each IR port remains lit for the length of time that IR Serial data is being generated I O yellow Lights when the I O...

Page 8: ...tate of the AxLink port Power Port 2 pin 3 5 mm mini Phoenix male connector Operating Environment Operating Temperature 0 C 32 F to 50 C 122 F Operating Humidity 20 to 85 RH Heat Dissipation Typical 2...

Page 9: ...3100 NI 3100 256 can be upgraded to provide one ICSHub and two ICSNet ports by installing the optional ICSNet daughter card FG2105 10 see Other AMX Equipment NI 3100 ICS 64MB Controller with ICSNet FG...

Page 10: ...le of voltage sensing Input format is software selectable with interactive power sensing for IR ports IR Serial Ports 9 16 8 IR Serial control ports support high frequency carriers of up to 1 142 MHz...

Page 11: ...te installed control card firmware NOTE Verify you are using the latest NI firmware for the on board Master Verify you are using the latest version of NetLinx Studio available for download from www am...

Page 12: ...nels 1 8 are active The LED for each I O port reflects the state of that particular port NetLinx Control Card Slots 1 4 Accepts up to 4 compatible NetLinx Cards NXC COM2 NXC I O10 etc Rear Panel Compo...

Page 13: ...rol devices Green AxLink LED indicates the state of the AxLink port Power Port 2 pin 3 5 mm mini Phoenix male connector CardFrame DIP Switch Sets the starting address for the Control Cards in the Card...

Page 14: ...100 Only The 8 position CardFrame Number DIP switch located on the rear of the NI 4100 sets the starting address the device number in the D P S specification for the Control Cards installed in the Car...

Page 15: ...ts 5 Re secure the faceplate by inserting the three faceplate screws by turning them in a clockwise direction and securing the front plate to the Integrated Controller 6 Re apply power and other conne...

Page 16: ...rd and gently pry the card out of the slot Repeat this process on the opposite card removal groove This alternating action causes the card to wiggle away from the on board connector pins 4 Slip your f...

Page 17: ...k should be such that the amount of air flow required for safe operation of the equipment is not compromised Mounting the equipment in the rack should be such that a hazardous condition is not achieve...

Page 18: ...g the installation test the incoming wiring by connecting the Controller s connectors to their terminal locations and applying power Verify that the unit is receiving power and functioning properly Di...

Page 19: ...or control problems If necessary place the on board Master in PRD mode and use the NetLinx Studio program to resolve the communication and or control problems with the resident NetLinx program Then d...

Page 20: ...needed pins Modes and Front Panel LED Blink Patterns The following table lists the modes and blink patterns for the front panel LEDs associated with each mode These patterns are not evident until afte...

Page 21: ...ower supply to provide power through the rear 2 pin 3 5 mm mini Phoenix PWR connector Use the power requirements referenced in the product s Specifications table to determine the power draw The incomi...

Page 22: ...2 pin 3 5 mm mini Phoenix cable Match the wiring locations of the on both the power supply and the terminal connector 2 Tighten the clamp to secure the two wires Do not tighten the screws excessively...

Page 23: ...figure gives a visual representation of the wiring specifications for the RS 232 422 485 Device connectors Refer to the rear of the unit for more detailed connector pinout information The table below...

Page 24: ...re bi directional ICSHub OUT Port Connections and Wiring The NI Controller must be equipped with the available ICSNet connectors for this functionality to be active The following table describes the p...

Page 25: ...V without harm When used for outputs the I O port acts as a switch to GND and is rated for 200mA 12 VDC The NI 2100 can use up to 4 I O ports The NI 3100 and NI 4100 can use up to 8 I O ports The PWR...

Page 26: ...using a short cable length 10 feet NetLinx Control Card Slot Connector NI 4100 only FIG 16 shows the 20 pin male connector that provides connection to the NetLinx Control Cards FIG 15 IR SERIAL male I...

Page 27: ...it uses SSL as a mechanism to configure and diagnose a NetLinx system This port value is used for secure Telnet communication Note SSH version 2 is only supported 22 TCP Telnet The NetLinx Telnet serv...

Page 28: ...m Port located on the rear of the Master itself This type of communication is used by the various AMX product for communication amongst themselves 1319 UDP TCP integration Solutions This feature on th...

Page 29: ...assume responsibility for errors or omissions AMX also reserves the right to alter specifications without prior notice at any time The AMX Warranty and Return Policy and related documents can be view...

Reviews: