Harman AMX NI-2100 Hardware Reference Manual Download Page 27

Connections and Wiring

27

NI-2100/3100/4100 - Hardware Reference Guide

LAN (Ethernet/RJ-45 Port): Connections and Wiring

NOTE: 

NI-x100 Controllers feature an Auto MDI/MDI-X LAN port. This provides the option of using either a standard (straight 

through), or a crossover LAN cable to communicate with a PC - both cable types will work.

The following table lists the pinouts, signals, and pairing for the LAN connector.      

FIG. 17 diagrams the RJ-45 pinouts and signals for the LAN RJ-45 connector and cable.

LAN LEDs

LAN Ports Used By the Integrated Controller

LAN RJ-45 Pinouts and Signals

Pin Signals

Connections

Pairing

Color

1

TX +

1 --------- 1

1 --------- 2 Orange-White

2

TX -

2 --------- 2

Orange

3

RX +

3 --------- 3

3 --------- 6 Green-White

4

no connection

4 --------- 4

Blue

5

no connection

5 --------- 5

Blue-White

6

RX -

6 --------- 6

Green

7

no connection

7 --------- 7

Brown-White

8

no connection

8 --------- 8

Brown

FIG. 17  

RJ-45 wiring diagram

FIG. 18  

LAN LEDs

LAN Port Descriptions

Port type

Description

Standard Port #

FTP

The on-board Master has a built-in FTP server.

21/20 (TCP)

SSH

The SSH port functions using the same interface as Telnet but over a secure shell where it uses SSL as 

a mechanism to configure and diagnose a NetLinx system.
This port value is used for secure Telnet communication.
Note: SSH version 2 is only supported.

22 (TCP)

Telnet

The NetLinx Telnet server provides a mechanism to configure and diagnose a NetLinx system.
For maximum flexibility, the Master can be configured to utilize a different port than 23, or disable 

Telnet completely from either Telnet or the Program Port located on the rear of the Master itself. Once 

disabled, the only way to enable Telnet again is from the Master’s Program port.

 23 (TCP)

HTTP

The Master has a built-in web server that complies with the HTTP 1.0 specification and supports all of 

the required features of HTTP v1.1.
This port is used for unsecure HTTP Internet communication between the web browser’s UI and the 

target Master.

80 (TCP)

HTTPS/SSL

This port is used by a web browser to securely communicate between the web server UI and the target 

Master. This port is also used to simultaneously encrypt this data using the SSL certificate information 

on the Master as a key.

443 (TCP)

SPD - Speed LED 

connection speed is 100 Mbps 

and turns Off when speed is

lights (yellow) when the

L/A - Link/Activity LED

lights (green) when the

LAN cables are

connected and terminated

10 Mbps.

correctly.

Summary of Contents for AMX NI-2100

Page 1: ...HARDWARE REFERENCE GUIDE NETLINX INTEGRATED CONTROLLERS NI 2100 NI 3100 NI 4100...

Page 2: ...nd the point where they exit from the apparatus 11 ONLY USE attachments accessories specified by the manufacturer 12 USE ONLY with a cart stand tripod bracket or table specified by the manufacturer or...

Page 3: ...allation of Compact Flash Upgrades 16 Closing and Securing the Outer Housing 17 Installing Into An Equipment Rack 17 Rack Mount Safety Instructions 17 Connections and Wiring 19 Setting the Configurati...

Page 4: ...Hub OUT Port Connections and Wiring 24 Relay Port Connections and Wiring 25 Relay Connections 25 Input Output I O Port Connections and Wiring 25 IR Serial Port Connections and Wiring 26 NetLinx Contro...

Page 5: ...easier by automatically identifying and communicating with devices which support this beaconing technology Features NI Controllers Features NI 2100 NetLinx Integrated Controllers Name FG Features NI...

Page 6: ...standardizing device and function definitions default touch panel button assignments and control and feedback methods NI Controllers Features Cont NI 4100 NetLinx Integrated Controllers Name FG Featur...

Page 7: ...ial channels 1 4 are transmitting control data on Ports 5 8 The LED indicator for each IR port remains lit for the length of time that IR Serial data is being generated I O yellow Lights when the I O...

Page 8: ...tate of the AxLink port Power Port 2 pin 3 5 mm mini Phoenix male connector Operating Environment Operating Temperature 0 C 32 F to 50 C 122 F Operating Humidity 20 to 85 RH Heat Dissipation Typical 2...

Page 9: ...3100 NI 3100 256 can be upgraded to provide one ICSHub and two ICSNet ports by installing the optional ICSNet daughter card FG2105 10 see Other AMX Equipment NI 3100 ICS 64MB Controller with ICSNet FG...

Page 10: ...le of voltage sensing Input format is software selectable with interactive power sensing for IR ports IR Serial Ports 9 16 8 IR Serial control ports support high frequency carriers of up to 1 142 MHz...

Page 11: ...te installed control card firmware NOTE Verify you are using the latest NI firmware for the on board Master Verify you are using the latest version of NetLinx Studio available for download from www am...

Page 12: ...nels 1 8 are active The LED for each I O port reflects the state of that particular port NetLinx Control Card Slots 1 4 Accepts up to 4 compatible NetLinx Cards NXC COM2 NXC I O10 etc Rear Panel Compo...

Page 13: ...rol devices Green AxLink LED indicates the state of the AxLink port Power Port 2 pin 3 5 mm mini Phoenix male connector CardFrame DIP Switch Sets the starting address for the Control Cards in the Card...

Page 14: ...100 Only The 8 position CardFrame Number DIP switch located on the rear of the NI 4100 sets the starting address the device number in the D P S specification for the Control Cards installed in the Car...

Page 15: ...ts 5 Re secure the faceplate by inserting the three faceplate screws by turning them in a clockwise direction and securing the front plate to the Integrated Controller 6 Re apply power and other conne...

Page 16: ...rd and gently pry the card out of the slot Repeat this process on the opposite card removal groove This alternating action causes the card to wiggle away from the on board connector pins 4 Slip your f...

Page 17: ...k should be such that the amount of air flow required for safe operation of the equipment is not compromised Mounting the equipment in the rack should be such that a hazardous condition is not achieve...

Page 18: ...g the installation test the incoming wiring by connecting the Controller s connectors to their terminal locations and applying power Verify that the unit is receiving power and functioning properly Di...

Page 19: ...or control problems If necessary place the on board Master in PRD mode and use the NetLinx Studio program to resolve the communication and or control problems with the resident NetLinx program Then d...

Page 20: ...needed pins Modes and Front Panel LED Blink Patterns The following table lists the modes and blink patterns for the front panel LEDs associated with each mode These patterns are not evident until afte...

Page 21: ...ower supply to provide power through the rear 2 pin 3 5 mm mini Phoenix PWR connector Use the power requirements referenced in the product s Specifications table to determine the power draw The incomi...

Page 22: ...2 pin 3 5 mm mini Phoenix cable Match the wiring locations of the on both the power supply and the terminal connector 2 Tighten the clamp to secure the two wires Do not tighten the screws excessively...

Page 23: ...figure gives a visual representation of the wiring specifications for the RS 232 422 485 Device connectors Refer to the rear of the unit for more detailed connector pinout information The table below...

Page 24: ...re bi directional ICSHub OUT Port Connections and Wiring The NI Controller must be equipped with the available ICSNet connectors for this functionality to be active The following table describes the p...

Page 25: ...V without harm When used for outputs the I O port acts as a switch to GND and is rated for 200mA 12 VDC The NI 2100 can use up to 4 I O ports The NI 3100 and NI 4100 can use up to 8 I O ports The PWR...

Page 26: ...using a short cable length 10 feet NetLinx Control Card Slot Connector NI 4100 only FIG 16 shows the 20 pin male connector that provides connection to the NetLinx Control Cards FIG 15 IR SERIAL male I...

Page 27: ...it uses SSL as a mechanism to configure and diagnose a NetLinx system This port value is used for secure Telnet communication Note SSH version 2 is only supported 22 TCP Telnet The NetLinx Telnet serv...

Page 28: ...m Port located on the rear of the Master itself This type of communication is used by the various AMX product for communication amongst themselves 1319 UDP TCP integration Solutions This feature on th...

Page 29: ...assume responsibility for errors or omissions AMX also reserves the right to alter specifications without prior notice at any time The AMX Warranty and Return Policy and related documents can be view...

Reviews: