15
1 -9 0 -0 9 7 3 0 R 2 6 _ 0 6 /1 3
This method also provides excellent venting for normal
operation but requires the stove to be installed farther from
the wall. The vertical portion of the vent should be three to
five feet high and at least three inches from a combustible
wall. This vertical section will provide natural draft in the event
of a power failure.
This method provides excellent venting for normal operation
and allows the stove to be installed closest to the wall. One
inch from the wall is safe however, two or three inches allows
better access to remove the rear panel. The vertical portion of
the vent should be three to five feet high. This vertical section
will provide natural draft in the event of a power failure.
ig. 20
ig. 21
V enting
CAUTION
K EEP COMBUSTIBLES (SUCH AS G R ASS, LEAV ES,
ETC.) AT LEAST 3 F EET AW AY F R OM THE F LUE
OUTLET ON THE OUTSIDE OF THE BUILDING .
3 ft.
to combustibles
3 ft.
to combustibles
3 ft.
to combustibles
3 ft.
to combustibles
# 1 Preferred method
# 2 Preferred method