A. Safety Reminders

When installing the Harman® Accentra 52i Pellet Insert, 

respect basic safety standards. Read these instructions 

carefully before you attempt to install or operate the 

Accentra 52i Pellet Insert. Failure to do so may result 

in damage to property or personal injury and may void 

the product warranty.
Consult  with  your  local  building  code  agency  and 

insurance  representative  before  you  begin  your 

installation  to  ensure  compliance  with  local  codes, 

including the need for permits and follow-up inspections.

MOBILE/MANUFACTURED HOME GUIDELINES DO 

NOT ALLOW INSTALLATION IN A SLEEPING ROOM.

THE STRUCTURAL INTEGRITY OF THE MOBILE 

HOME FLOOR, WALL, AND CEILING/ROOF MUST BE 

MAINTAINED.

THE STOVE IS HOT WHILE IN OPERATION.
KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. 

CONTACT MAY CAUSE SKIN BURNS.

KEEP COMBUSTIBLE MATERIALS SUCH AS GRASS, 

LEAVES, ETC. AT LEAST 3 FEET AWAY FROM THE 

POINT DIRECTLY UNDER THE VENT TERMINATION.

USE OF IMPROPER FUELS, FIRE STARTERS OR 

ALTERING THE STOVE FOR HIGHER HEAT OUTPUT 

MAY CAUSE DAMAGE TO THE STOVE AND COULD 

RESULT IN A HOUSE FIRE. USE ONLY APPROVED 

FUELS AND OPERATION GUIDELINES

DO NOT USE MAKESHIFT COMPONENTS OR 

OTHER COMPROMISES WHEN INSTALLING THIS 

APPLIANCE.

WARNING

!

WARNING

!

WARNING

!

CAUTION

!

CAUTION

!

CAUTION

!

Due to high temperatures, this stove should be placed 

out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards 

of high surface temperatures and should stay away to 

avoid burn to skin and/or clothing.
Young children should be carefully supervised when 

they are in the same room as the stove.
Clothing and other flammable materials should not be 

placed on or near this stove.
Installation and repair of this stove should be done by 

a  qualified  service  person. The  appliance  should  be 

inspected before use and at least annually by a qualified 

service person. More frequent cleaning will be required. 

It is imperative that control compartments, burners, and 

circulating air passageways of this stove be kept clean.

CAUTION

!

This appliance must be vented to the outside.

Summary of Contents for Accentra 52i Pellet Insert

Page 1: ...comply with local regional state and national codes and regulations Contact local building or fire officials about restrictions and installation inspection requirements in your area Tested and approve...

Page 2: ...ons 4 E Non Combustible Materials Specification 5 F Combustible Materials Specification 5 G Electrical Codes 5 2 Getting Started A Design and Installation Considerations 6 B Tools and Supplies Needed...

Page 3: ..._____________ Electrical Section 1 Pg 4 120 VAC unswitched power provided to the appliance ________________________________ Finishing Sections 3 4 Pg 8 14 Combustible materials not installed in non co...

Page 4: ...LABORATORY OMNI Test Laboratories Inc REPORT NO 135 S 31 2 TYPE Pellet Fueled Insert Supplementary For Residential Use STANDARD s ASTM E1509 12 ULC S628 93 EPA Method 28 5G D BTU Efficiency Specifica...

Page 5: ...ay not be compatible with the micro processor electronics on this appliance Please consult the power supply manufacturer for compatible systems WARNING Risk of Fire Hearth Home Technologies disclaims...

Page 6: ...OT recommended Not the highest point of the roof Wind loading possible Multi level Roofs Windward Leeward Recommended Outside Air Intake on windward side NOT recommended Outside Air Intake on leeward...

Page 7: ...glass Read all of the instructions before starting the installation Follow these instructions carefully during the installation to ensure maximum safety and benefit WARNING Risk of Fire or Explosion...

Page 8: ...tual appliance dimensions Use for reference only Figure 3 1 32 1 8 41 13 16 31 5 16 22 20 24 18 9 16 29 15 16 13 16 15 9 16 14 3 8 12 3 4 Unit 1 90 574240 Hopper Capacity 64 5 lbs 29 25 kg Unit 1 90 5...

Page 9: ...are not drawn to scale Actual installation may vary due to individual design preference A to sidewall B to 12 mantel C to 3 4 trim D to 3 4 trim E floor protection Floor protection must be used from...

Page 10: ...r is provided from the living area and enters the feed system from around the wing and stove body spaces The chimney top must be capped to prevent rain and or snow from entering the chimney See Page 1...

Page 11: ...The damper area must be sealed with a steel plate and it is recommended that Kaowool Mineral wool or an equivalent non combustible insulation is used on top of the plate to reduce the possibility of c...

Page 12: ...replace seal the damper area around the chimney liner with fiberglass batting Note If the Harman Accentra 52i Pellet Insert is installed into a factory built wood burning fireplace this label Harman p...

Page 13: ...ughs and terminations are used Note Flex pipe is not approved these types of installation Detailed installation instructions are included with the Zero Clearance Cabinet These same installation instru...

Page 14: ...horizontal venting will require more frequent cleaning It is the responsibility of the installer to make sure the entire flue configuration is accessible for cleaning 4 stainless steel flex vent pipin...

Page 15: ...recognize when power is restored What happens depends on ESP temperature and whether it is equipped with automatic ignition In Automatic setting units equipped with automatic ignition will respond to...

Page 16: ...ressure gauge capable of reading 0 1 inches of water column W C The appliance should be running on high for at least 15 minutes for the test With the stove running on high you should have a negative p...

Page 17: ...own and Power Failure To reduce the probability of back drafting or burn back in the pellet burning appliance during power failure or shut down conditions the stove must be able to draft naturally wit...

Page 18: ...ert operates with a positive vent pressure we specify that the joints also be sealed with silicone Where passing through an exterior wall or roof be sure to use the appropriate pass through device pro...

Page 19: ...each end with an NEC approved grounding device 5 Refer to Clearances to Combustibles and Floor Protection section of this manual for listings to combustibles 6 Use silicone to create an effective vapo...

Page 20: ...ents Remove appliance and components from packaging and inspect for damage Report to your dealer any parts damaged in shipment Read all the instructions before starting the installation Follow these i...

Page 21: ...hinge pins See Figure 5 1 2 Remove the ash pan 3 Remove the 4 internal pieces of cast iron Figure 5 2 See Figure 5 3 and Figure 5 4 for removal instructions Figure 5 2 Center Medallion Flame Guide Hea...

Page 22: ...y by pulling up on the latch located at the bottom right corner of firebox Figure 5 4 2 Remove the heat exchanger cover by lifting it upward about 1 2 inch and move the bottom edge front until it sits...

Page 23: ...he surround If a right side cord is desired follow the instructions below The cord is located on the left side standard from Harman To route the cord to the right side 1 Cut the wire ties looping the...

Page 24: ...he location where the extension wire 18 2 thermostat wire not supplied by Harman can be spliced to go to the wall location chosen for the room sensor If the room sensor is used as a return air sensor...

Page 25: ...hes to secure the stove and remove the service rail kit Re install the heat exchanger covers and medallion Install and adjust the side panel magnets onto the cast iron ash lip In the hardware pack are...

Page 26: ...out of the frame even if it is only pulled out several inches Always inspect the wiring harness of the 11 pin socket large white flat plug where all of the power wires terminate Always inspect the wir...

Page 27: ...usted too low the low draft pressure switch will not allow the feeder motor or the igniter to operate After the installation is completed but before the first fire is lit check and record the high and...

Page 28: ...POINT DIRECTLY UNDER THE VENT TERMINATION USE OF IMPROPER FUELS FIRE STARTERS OR ALTERING THE STOVE FOR HIGHER HEAT OUTPUT MAY CAUSE DAMAGE TO THE STOVE AND COULD RESULT IN A HOUSE FIRE USE ONLY APPR...

Page 29: ...RE IS GROUND RED GREEN 6 AMP GLASS FUSE HARMAN ACCENTRA 52I PELLET STOVE 1 90 574000 B R O W N G R E E N Y E L LO W WHITE GREEN WIRE IS GROUND BONDED TO STOVE BODY BLACK W H I T E MALE FEMALE CONNECTI...

Page 30: ...___ 09 15 30 3 90 00574i 352 Mountain House Road Halifax PA 17032 www harmanstoves com Please contact your Harman dealer with any questions or concerns For the location of your nearest Harman dealer p...

Reviews: