Placing the rail
The R27LS rail can be installed with installation angles and limitations as indicated in the respective
Regulations for which compliance has been verified. Below is the graph of the regulatory fields of application
based on the angle of installation of the line (Pic.A).
90°
0°
75°
15°
EN 353-1:2014+A1:2017
PPE-R/11.116(v2)
EN 795:2012
90°
15°
15°
15°
90°
15°
15°
15°
90°
Pic.A
The R27LS rail installed from 0° to 5° with respect to the horizontal plane can be mounted in any position: floor,
wall, ceiling and intermediate angles.
The installation of the rail for the INCAR-360 trolley is only allowed on the floor, wall or staircase respecting the
angles indicated in the table.
Positioning of the rail according to the trolleys used:
Floor
Wall
Ceiling
Stairs
All trolley (0-5°)*
except INCAR-360
INCAR-360 (0-5°)*
INCAR-360 (6-74°)*
INCAR-360 (75-90°)*
* Angles referred to the horizontal plane
Ceiling
Wa
ll
Floor
WARNING!
The rail used with the INCAR-360 trolley cannot be
ceiling mounted.
Summary of Contents for R27LS
Page 2: ......
Page 53: ...26 01 22 ENGLISH 53 INBRKT X5 INBRKT X6...
Page 57: ...26 01 22 ENGLISH 57 INMID ENTRY1 LS 60 60 160 400 116 5 116 5 0 5 0 5 43 2 INMID ENTRY1 LS...
Page 58: ...58 ENGLISH 26 01 22 INMID ENTRY3 LS 400 116 5 116 5 58 86 28 31 INMID ENTRY3 LS...
Page 66: ...66 ENGLISH 26 01 22 326 326 412 412 49 INTURN1 LS...
Page 67: ...26 01 22 ENGLISH 67 326 652 412 49 INTURN2 LS...
Page 73: ...26 01 22 ENGLISH 73 250mm INLINK LS INLINK LS INSTOP LS INSTOP LS 10 1 cm L6...
Page 74: ...74 ENGLISH 26 01 22 250mm INLINK LS INLINK LS INSTOP LS INSTOP LS 10 1 cm L7...